MAINT-15: the balancing hold ends on time with no SoC reading
HOLD's time check moves into Maintenance._hold(), used by step() and
_no_soc(). A hold that loses its SoC now ends at hold_min, writes
last_completed and logs the same COMPLETE line. The 15 min HOLD line says
the hold still ends at its normal time. Behaviour with a reading is
unchanged (differential trace against db9e231).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -58,10 +58,7 @@ allows discharge.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- **HOLD with no SoC** still holds 0 W and, as before, does not end while the
|
||||
reading is missing: its time check sits behind the same early return. A HOLD
|
||||
needs no level to end, so this is a candidate follow-up, not part of this fix. It is card MAINT-15. The "no battery level" line in
|
||||
HOLD says only that the hold waits for the level.
|
||||
- **HOLD with no SoC**: closed by MAINT-15 (`MAINT-15-hold-ends-without-soc.md`).
|
||||
- It does not tell the operator why the reading is missing (sensor, register,
|
||||
link). It does not reuse the stale-input gate; it is the cycle's own rule.
|
||||
- The charge itself is still driven by the control loop, which has its own
|
||||
|
||||
@@ -0,0 +1,43 @@
|
||||
# MAINT-15 - the balancing hold ends on time with no SoC reading
|
||||
|
||||
**Status: for review.** Tests: `test_maint15.py`. No option added.
|
||||
|
||||
**The fault.** `step()` sent every tick with no SoC to `_no_soc()`, and for
|
||||
HOLD that returned 0 W without the time check. A hold that lost its reading
|
||||
never ended: `last_completed` was never written and the next due date never
|
||||
moved. Harmless for power (0 W), but the cycle was stuck. This was left open
|
||||
in MAINT-14.
|
||||
|
||||
## Rule
|
||||
|
||||
1. **HOLD ends at `hold_min` whether or not there is a reading.** One helper,
|
||||
`Maintenance._hold()`, holds the time check and is used by both paths. When
|
||||
the time is up it writes `last_completed`, goes IDLE and logs the same
|
||||
"cycle COMPLETE" line. Before the time is up it commands 0 W as before.
|
||||
2. **Text.** The 15-min "no battery level" line in HOLD now reads "The hold
|
||||
still ends at its normal time." Still once per episode.
|
||||
|
||||
## Why
|
||||
|
||||
HOLD is reached only after the charge counted as done. Every entry into HOLD
|
||||
is in `step()` or `_no_soc()` and follows a charge that reached the target,
|
||||
stalled near full (MAINT-13) or timed out near full (MAINT-13/14). Nothing else
|
||||
sets the phase to HOLD (`_enter(HOLD` has four call sites, all after a done
|
||||
charge). The hold is a wait for the BMS to balance; it never needed the level.
|
||||
So a hold that ends with no reading is a completed cycle. The "cycle COMPLETE"
|
||||
line is true without a reading: it names minutes of hold, not a level.
|
||||
|
||||
## Cost
|
||||
|
||||
- If the level was lost during the hold, the cycle is recorded as complete
|
||||
without anyone seeing the final level. The charge had counted as done, so this
|
||||
is the same trust MAINT-14 already gives a charge that ends with no reading.
|
||||
|
||||
## What this does not cover
|
||||
|
||||
- It does not check that the pack is still full at the end of the hold.
|
||||
- It does not say why the reading was lost.
|
||||
- With a reading, nothing changes (proved by a differential trace against
|
||||
release/1.0 in `test_maint15.py`).
|
||||
- A state file written by an older version with `phase: hold` loads and ends on
|
||||
time; the file is not changed in format.
|
||||
@@ -541,11 +541,29 @@ class Maintenance:
|
||||
events.append(msg)
|
||||
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
|
||||
|
||||
def _hold(self, now: datetime, events: list) -> MaintResult:
|
||||
"""HOLD for one tick, with or without a SoC reading (MAINT-15).
|
||||
|
||||
HOLD needs no level to end: it is reached only after the charge counted
|
||||
as done (MAINT-13/14), so its end is a time check and nothing else.
|
||||
"""
|
||||
elapsed = self._elapsed_min(now)
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
|
||||
def _no_soc(self, now: datetime, phase: str, gate_open: bool,
|
||||
events: list) -> MaintResult:
|
||||
"""MAINT-14: one tick of a pack in a moving phase with no SoC reading.
|
||||
|
||||
HOLD is unchanged (0 W). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
HOLD stays at 0 W and ends at its normal time (MAINT-15). DRAIN holds at 0 W, like HOLD, and its 12 h
|
||||
timeout still runs. CHARGE keeps its timeout and wall backstop: out of
|
||||
time is a failure, except when the last SoC seen was within
|
||||
CHARGE_NEAR_FULL_PCT of the target, which counts as done (MAINT-13).
|
||||
@@ -563,7 +581,7 @@ class Maintenance:
|
||||
if (not self._nosoc_said and (now - self._nosoc_since).total_seconds()
|
||||
>= NOSOC_NOTE_MIN * 60):
|
||||
self._nosoc_said = True
|
||||
tail = ("The hold waits for the level to come back."
|
||||
tail = ("The hold still ends at its normal time."
|
||||
if phase == HOLD else
|
||||
f"The time limit of the {phase} still applies.")
|
||||
msg = (f"maintenance: no battery level for {NOSOC_NOTE_MIN} min. "
|
||||
@@ -571,7 +589,7 @@ class Maintenance:
|
||||
_LOG.warning("%s", msg)
|
||||
events.append(msg)
|
||||
if phase == HOLD:
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
elapsed = self._elapsed_min(now)
|
||||
if phase == DRAIN:
|
||||
if elapsed > DRAIN_TIMEOUT_MIN:
|
||||
@@ -736,16 +754,7 @@ class Maintenance:
|
||||
return MaintResult(CHARGE, False, None, True, events)
|
||||
|
||||
if phase == HOLD:
|
||||
if elapsed >= self.cfg.hold_min:
|
||||
self.store.set_time("last_completed", now)
|
||||
self._enter(IDLE, now, events,
|
||||
f"maintenance: cycle COMPLETE ({elapsed:.0f} min hold) "
|
||||
"- handing back to the loop")
|
||||
return MaintResult(IDLE, False, None, False, events)
|
||||
# 0 W, not "do nothing": commanding zero is what stops the loop
|
||||
# pulling the pack straight back down the moment it is full, which
|
||||
# is exactly when the BMS needs it parked at the top.
|
||||
return MaintResult(HOLD, True, 0.0, False, events)
|
||||
return self._hold(now, events)
|
||||
|
||||
_LOG.error("maintenance: unknown phase %r, forcing idle", phase)
|
||||
events += self.abort(now, f"unknown phase {phase!r}")
|
||||
|
||||
@@ -245,8 +245,8 @@ m = in_charge()
|
||||
m.tick(T0 + MIN, 100.0)
|
||||
_, _, _, ev = run(m, T0 + 2 * MIN, 30, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("HOLD: the line exists and claims no time limit",
|
||||
len(note) == 1 and "time limit" not in note[0] and "waits" in note[0])
|
||||
check("HOLD: the line exists and says the hold ends at its normal time (MAINT-15)",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0])
|
||||
m = in_charge()
|
||||
_, _, _, ev = run(m, T0, 30, None)
|
||||
check("charge keeps its wording", any("time limit of the charge" in e for e in ev))
|
||||
@@ -268,7 +268,7 @@ _, _, out, _ = run(m, T0 + 10 * MIN, CHARGE_TIMEOUT_MIN + 20, None)
|
||||
_, _, _, ev = run(m, out[1] + MIN, 30, None)
|
||||
check("charge done with no SoC, then HOLD with no SoC: a new episode, so the "
|
||||
"HOLD line is said", out[0].phase == HOLD
|
||||
and sum("hold waits" in e for e in ev) == 1)
|
||||
and sum("normal time" in e for e in ev) == 1)
|
||||
|
||||
print("6. restart while the SoC is missing")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
|
||||
@@ -0,0 +1,255 @@
|
||||
"""MAINT-15: the HOLD ends on time with no SoC reading.
|
||||
`python3 test_maint15.py`
|
||||
|
||||
Graded here: a HOLD that loses its SoC (at the start, mid-hold, just before
|
||||
hold_min) ends on time, writes last_completed and says the COMPLETE line; SoC
|
||||
back mid-hold changes nothing; HOLD stays 0 W; one pack's loss leaves the other
|
||||
pack alone; a restart in HOLD with no SoC and an old state file.
|
||||
See DECISIONS/MAINT-15-hold-ends-without-soc.md.
|
||||
|
||||
Mutating what this file grades? Read MUTATION.md first (stale bytecode).
|
||||
"""
|
||||
|
||||
import os
|
||||
import sys
|
||||
import tempfile
|
||||
from datetime import datetime, timedelta, timezone
|
||||
|
||||
from app.maintenance import (
|
||||
CHARGE, CHARGE_NEAR_FULL_PCT, CHARGE_TIMEOUT_MIN, CHARGE_WALL_TIMEOUT_MIN,
|
||||
DRAIN, DRAIN_TIMEOUT_MIN, FAIL_BACKOFF_DAYS, HOLD, IDLE, NOSOC_NOTE_MIN,
|
||||
MaintConfig, Maintenance, arbitrate,
|
||||
)
|
||||
from app.store import DEFAULTS, Store
|
||||
|
||||
UTC = timezone.utc
|
||||
fails = []
|
||||
|
||||
|
||||
def check(name, cond):
|
||||
print(f" {'ok ' if cond else 'FAIL'} {name}")
|
||||
if not cond:
|
||||
fails.append(name)
|
||||
|
||||
|
||||
CFG = MaintConfig(enabled=True, interval_days=28, start_hour=19,
|
||||
discharge_w=2000, charge_w=2000, soc_floor=11,
|
||||
soc_target=100, hold_min=120)
|
||||
T0 = datetime(2026, 10, 4, 18, 24, tzinfo=UTC)
|
||||
MIN = timedelta(minutes=1)
|
||||
|
||||
|
||||
class Mem:
|
||||
def __init__(self, data=None):
|
||||
self.data = dict(DEFAULTS, **(data or {}))
|
||||
|
||||
def set(self, k, v):
|
||||
self.data[k] = v
|
||||
|
||||
def set_time(self, k, when):
|
||||
self.data[k] = when.astimezone(UTC).isoformat() if when else None
|
||||
|
||||
def get_time(self, k):
|
||||
raw = self.data.get(k)
|
||||
return datetime.fromisoformat(raw) if raw else None
|
||||
|
||||
def save(self):
|
||||
pass
|
||||
|
||||
|
||||
def in_drain(store=None, unit=None, at=T0):
|
||||
m = Maintenance(CFG, store or Mem(), unit=unit, name=unit or "")
|
||||
m.force_start(at)
|
||||
assert m.phase == DRAIN
|
||||
return m
|
||||
|
||||
|
||||
def in_charge(store=None, unit=None, at=T0):
|
||||
m = in_drain(store, unit, at)
|
||||
m.tick(at, 11.0)
|
||||
assert m.phase == CHARGE
|
||||
return m
|
||||
|
||||
|
||||
def run(m, start, minutes, soc, gate=True, step=1):
|
||||
"""Tick every `step` min; returns (last result, end time, first result that
|
||||
is not the starting phase with its time, all events)."""
|
||||
ph, t, res, out, ev = m.phase, start, None, None, []
|
||||
for i in range(0, minutes, step):
|
||||
t = start + i * MIN
|
||||
s = soc(i) if callable(soc) else soc
|
||||
res = m.tick(t, s, gate_open=gate)
|
||||
ev += res.events
|
||||
if out is None and res.phase != ph:
|
||||
out = (res, t)
|
||||
break
|
||||
return res, start + minutes * MIN, out, ev
|
||||
|
||||
|
||||
|
||||
HOLD_MIN = CFG.hold_min
|
||||
|
||||
|
||||
def in_hold(store=None, unit=None, at=T0):
|
||||
"""A pack in HOLD that started at `at` + 1 min (charge counted as done)."""
|
||||
m = in_charge(store, unit, at)
|
||||
m.tick(at + MIN, 100.0)
|
||||
assert m.phase == HOLD
|
||||
return m
|
||||
|
||||
|
||||
H0 = T0 + MIN # the hold's start
|
||||
print("1. SoC lost in HOLD: the hold ends on time")
|
||||
for label, lost_at in (("at the start", 0), ("mid-hold", 60),
|
||||
("just before hold_min", HOLD_MIN - 1)):
|
||||
m = in_hold()
|
||||
run(m, H0, lost_at, 100.0) if lost_at else None
|
||||
res, _, out, ev = run(m, H0 + lost_at * MIN, HOLD_MIN + 5 - lost_at, None)
|
||||
check(f"lost {label}: ends at hold_min, to IDLE, not failed",
|
||||
out is not None and out[0].phase == IDLE and out[0].failed == ""
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...last_completed is written at that time",
|
||||
m.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
check("...the same COMPLETE line, once, and no last_failed",
|
||||
sum("cycle COMPLETE (120 min hold)" in e for e in ev) == 1
|
||||
and m.store.get_time("last_failed") is None)
|
||||
check("...the pack is idle and hands the setpoint back",
|
||||
m.phase == IDLE and not out[0].owns_setpoint)
|
||||
|
||||
m = in_hold()
|
||||
res, _, out, _ = run(m, H0, HOLD_MIN - 1, None)
|
||||
check("before hold_min: still HOLD at 0 W, owned, nothing written",
|
||||
out is None and res.phase == HOLD and res.owns_setpoint
|
||||
and res.setpoint_w == 0.0 and m.store.get_time("last_completed") is None)
|
||||
check("...the pack is not due again (next due date moved after the end)",
|
||||
(run(m, H0 + (HOLD_MIN - 1) * MIN, 3, None), m.due(H0 + 130 * MIN))[1] is False)
|
||||
|
||||
print("2. the text")
|
||||
m = in_hold()
|
||||
_, _, out, ev = run(m, H0, HOLD_MIN + 5, None)
|
||||
note = [e for e in ev if "no battery level for" in e]
|
||||
check("one 15 min line, saying the hold ends at its normal time",
|
||||
len(note) == 1 and "normal time" in note[0] and "waits" not in note[0]
|
||||
and f"{NOSOC_NOTE_MIN} min" in note[0])
|
||||
check("...and the other events are the one COMPLETE line only", len(ev) == 2)
|
||||
m = in_hold()
|
||||
_, _, _, ev = run(m, H0, NOSOC_NOTE_MIN - 2, None)
|
||||
check("under the threshold the line is not said", ev == [])
|
||||
|
||||
print("3. SoC comes back mid-hold")
|
||||
ends = {}
|
||||
for label, soc in (("no SoC", lambda i: None if i < 40 else 100.0),
|
||||
("SoC the whole time", 100.0),
|
||||
("a low SoC after the gap", lambda i: None if i < 40 else 55.0)):
|
||||
m = in_hold()
|
||||
res, _, out, ev = run(m, H0, HOLD_MIN + 5, soc)
|
||||
ends[label] = (out[1], m.store.get_time("last_completed")) if out else None
|
||||
check(f"{label}: ends at hold_min", out is not None
|
||||
and out[1] == H0 + HOLD_MIN * MIN)
|
||||
check("...the end time is the same with or without the gap",
|
||||
len(set(ends.values())) == 1)
|
||||
m = in_hold()
|
||||
run(m, H0, 40, None)
|
||||
res, _, out, _ = run(m, H0 + 40 * MIN, 30, 100.0)
|
||||
check("back mid-hold: still HOLD at 0 W until the time is up",
|
||||
out is None and res.phase == HOLD and res.setpoint_w == 0.0)
|
||||
|
||||
print("4. restart in HOLD with no SoC")
|
||||
with tempfile.TemporaryDirectory() as d:
|
||||
path = os.path.join(d, "state.json")
|
||||
m = Maintenance(CFG, Store(path))
|
||||
m.force_start(T0)
|
||||
m.tick(T0, 11.0)
|
||||
m.tick(H0, 100.0)
|
||||
run(m, H0, 50, None)
|
||||
m2 = Maintenance(CFG, Store(path))
|
||||
r = m2.tick(H0 + 51 * MIN, None)
|
||||
check("a fresh process reads HOLD and holds 0 W", m2.phase == HOLD
|
||||
and r.phase == HOLD and r.owns_setpoint and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(m2, H0 + 52 * MIN, HOLD_MIN, None)
|
||||
check("...and the hold ends at hold_min from the hold start, not the restart",
|
||||
out and out[0].phase == IDLE and out[1] == H0 + HOLD_MIN * MIN
|
||||
and m2.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
import json
|
||||
old = {"phase": "hold", "phase_started": H0.isoformat(),
|
||||
"last_completed": None, "last_start_attempt": None, "auto": True}
|
||||
p2 = os.path.join(d, "old.json")
|
||||
json.dump(old, open(p2, "w"))
|
||||
mo = Maintenance(CFG, Store(p2))
|
||||
r = mo.tick(H0 + 10 * MIN, None)
|
||||
check("an old state file in HOLD loads and holds 0 W", mo.phase == HOLD
|
||||
and r.setpoint_w == 0.0)
|
||||
res, _, out, _ = run(mo, H0 + 11 * MIN, HOLD_MIN, None)
|
||||
check("...and ends on time, writing last_completed",
|
||||
out and out[1] == H0 + HOLD_MIN * MIN
|
||||
and mo.store.get_time("last_completed") == H0 + HOLD_MIN * MIN)
|
||||
mr = Maintenance(CFG, Store(p2))
|
||||
check("...the written file reloads as a finished cycle",
|
||||
mr.phase == IDLE and mr.store.get_time("last_completed") is not None)
|
||||
|
||||
print("5. two packs")
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a_ok, b_ok = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
for x in (a, a_ok):
|
||||
x.force_start(T0)
|
||||
x.tick(T0, 11.0)
|
||||
x.tick(H0, 100.0)
|
||||
# B is idle; A's hold loses its SoC (twin site: A keeps it)
|
||||
same, a_end = True, None
|
||||
for i in range(0, HOLD_MIN + 10):
|
||||
t = H0 + i * MIN
|
||||
ra = a.tick(t, None)
|
||||
rb = b.tick(t, 60.0)
|
||||
ra2 = a_ok.tick(t, 100.0)
|
||||
rb2 = b_ok.tick(t, 60.0)
|
||||
same = same and (rb.phase, rb.owns_setpoint, rb.setpoint_w) == \
|
||||
(rb2.phase, rb2.owns_setpoint, rb2.setpoint_w) and b.phase == b_ok.phase
|
||||
if a_end is None and a.phase == IDLE:
|
||||
a_end = t
|
||||
check("A loses SoC in HOLD: A ends on time (as the twin with a reading)",
|
||||
a_end == H0 + HOLD_MIN * MIN and a_ok.phase == IDLE
|
||||
and a.store.get_time("last_completed") == a_ok.store.get_time("last_completed"))
|
||||
check("...B is the same as in the twin site where A kept its SoC", same)
|
||||
# B in its own HOLD with SoC, A in HOLD without
|
||||
a, b = (Maintenance(CFG, Mem(), unit="inverter-a", name="inverter-a"),
|
||||
Maintenance(CFG, Mem(), unit="inverter-b", name="inverter-b"))
|
||||
a.force_start(T0); a.tick(T0, 11.0); a.tick(H0, 100.0)
|
||||
b_start = H0 + 30 * MIN
|
||||
b.force_start(b_start - MIN); b.tick(b_start - MIN, 11.0); b.tick(b_start, 100.0)
|
||||
b_end = None
|
||||
for i in range(0, HOLD_MIN + 40):
|
||||
t = H0 + i * MIN
|
||||
a.tick(t, None)
|
||||
if t >= b_start:
|
||||
b.tick(t, 100.0)
|
||||
if b_end is None and b.phase == IDLE:
|
||||
b_end = t
|
||||
check("B (SoC present) ends at its own hold_min, A's loss changes nothing",
|
||||
b_end == b_start + HOLD_MIN * MIN and a.phase == IDLE
|
||||
and b.store.get_time("last_completed") == b_start + HOLD_MIN * MIN)
|
||||
check("...A's end is not delayed by B", a.store.get_time("last_completed")
|
||||
== H0 + HOLD_MIN * MIN)
|
||||
|
||||
print("6. other phases unchanged")
|
||||
m = in_drain()
|
||||
res, _, out, _ = run(m, T0, 60, None)
|
||||
check("DRAIN with no SoC still holds 0 W and does not end", out is None
|
||||
and res.phase == DRAIN and res.setpoint_w == 0.0)
|
||||
m = in_charge()
|
||||
res, _, out, _ = run(m, T0, 600, None)
|
||||
check("CHARGE with no SoC still keeps charging", out is None
|
||||
and res.phase == CHARGE and res.charge_only)
|
||||
m = in_hold()
|
||||
res, _, out, _ = run(m, H0, 30, 100.0)
|
||||
check("HOLD with a reading is unchanged: 0 W, ends at hold_min", out is None
|
||||
and res.setpoint_w == 0.0)
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED:")
|
||||
for f in fails:
|
||||
print(" -", f)
|
||||
sys.exit(1)
|
||||
print("all ok")
|
||||