EV-05 round 9: one test of control; another writer's phases are a hold
checks / unit (pull_request) Successful in 31m31s
infra-pin / fresh (pull_request) Successful in 2s

SolarWriter.in_control is the single test of "Solar has the charger":
writing, read-back current and phases are Solar's own, no hold, no write
refused, given up or owed. Alarm grading, banking, the own-pause grace and
the cut use it. A phase change Solar did not make is another writer:
nothing written over it, hold after 30 s, no select back after 10 min.
While Solar's own switch waits, a lower current is written at once, and
the arithmetic uses the phases the car draws on. A car another writer
starts inside the own-pause grace is no longer graded out.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
ems-agent
2026-11-18 23:49:47 +01:00
co-authored by Claude Opus 5.5
parent e348a808ff
commit c9a95f3c10
5 changed files with 211 additions and 24 deletions
@@ -138,6 +138,23 @@ inputs (`car_sun_inputs`) and runs the writer in the same background task.
`OWN_PAUSE_MAX_S`. A car another writer starts while Solar waits at 0 A for
sun gets the alarms as in Off.
## Round 9 (review of e348a80)
- **One test of control**: `SolarWriter.in_control`. Solar writes, the
read-back current AND phases are what it set (`own_rb`), there is no hold,
and no write of its own is refused, given up or owed. The alarm grading,
the banking, EV-15's own-pause grace and the cut all use it.
- **A phase change Solar did not make is another writer**, like a current
change: nothing is written over it, and after `WRITER_S` the hold
(CHARGER_OTHER). Solar no longer selects its own phases back after the
10 minutes. A select the charger did not confirm counts both phases as
Solar's until the read-back shows one.
- **While Solar's own phase switch waits** (`PHASE_GAP_S`), a lower current
(the cut, the hold's 6 A) is written at once. The arithmetic uses the
phases the car draws on.
- **The own-pause grace ends when the read-back is not Solar's 0 A**: a car
another writer starts inside it gets the alarms as in Off.
## Solar kWh
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,