diff --git a/goodwe_controller/DECISIONS/SAFETY-103-old-readings-after-a-drain.md b/goodwe_controller/DECISIONS/SAFETY-103-old-readings-after-a-drain.md index 8f2adc7..eb271fc 100644 --- a/goodwe_controller/DECISIONS/SAFETY-103-old-readings-after-a-drain.md +++ b/goodwe_controller/DECISIONS/SAFETY-103-old-readings-after-a-drain.md @@ -70,8 +70,9 @@ still swing up to 130 W, a third of a slew step. the saturation freeze (SAFETY-96), unchanged. - A lost link or a refusal ends the tail at once (A is out of the split, or reads ~0 W). The swing after them is the loop's own on a lagging plant, - the same with 1 s registers and on release/1.0 (up to 1.9 kW at N=3 under - a surplus): not this card. + the same with 1 s registers and on release/1.0: under a surplus up to + 1.5 kW at N=2 and 3.9 kW summed at N=3; after a lost link about 1 kW + even without one. Not this card. - A battery that overshoots its command, or a reading offset beyond the range, can put the true power outside the range; the meter then moves the point, as before.