Merge pull request 'PKG-06: bump 0.6.0 -> 0.7.0, because the schema changed and nobody bumped' (#55) from PKG-06-version-0.7.0 into release/1.0
This commit was merged in pull request #55.
This commit is contained in:
@@ -1,5 +1,34 @@
|
|||||||
# Changelog
|
# Changelog
|
||||||
|
|
||||||
|
## 0.7.0
|
||||||
|
|
||||||
|
⚠️ **SCHEMA CHANGE, AND IT IS WHY THIS IS A MINOR BUMP RATHER THAN A PATCH.**
|
||||||
|
[[SAFETY-32]] adds `bms_soc_floor: int(0,50)` as a **required** per-entry key on
|
||||||
|
the `inverters` roster - no trailing `?`. A config that declares a roster and
|
||||||
|
omits it on any entry is REFUSED at startup. An install running `inverters: []`,
|
||||||
|
which is every single-inverter install including the reference one, is
|
||||||
|
unaffected: the flat `bms_soc_floor` still describes the one pack.
|
||||||
|
|
||||||
|
CFG-04 recorded the rule this follows - the Supervisor keys the built image by
|
||||||
|
`version:`, so a schema change without a bump is a schema nobody reads.
|
||||||
|
|
||||||
|
Contents, in merge order since 0.6.0 (`2d025ee`):
|
||||||
|
|
||||||
|
| | |
|
||||||
|
|---|---|
|
||||||
|
| `3934ad7` | MAINT-05 - one recalibration per pack, migration graded against the roster |
|
||||||
|
| `67e649a` | SPIKE-04a - inverter B and pack B recorded, from datasheet and serial |
|
||||||
|
| `3993f9f` | SAFETY-32 - per-pack `bms_soc_floor`, rule 8 per unit, package-wide roster pin |
|
||||||
|
| `f72c48d` | UX-01 - add-on configuration in English and Dutch |
|
||||||
|
| `86eaef2` | TEL-07 - a second MQTT device for inverter B; A's identity byte-identical |
|
||||||
|
| `4482cd8` | SAFETY-41 - the clamp alarm stops narrating normal anti-windup |
|
||||||
|
|
||||||
|
⚠️ **0.6.0 WAS NEVER SECTIONED.** Its content sits below this heading rather than
|
||||||
|
under one of its own, because the bump shipped without cutting the section. That
|
||||||
|
is a defect in this file, not in the release: the deployed 0.6.0 is `2d025ee` and
|
||||||
|
the table above is what is new since it. Splitting it retroactively would mean
|
||||||
|
guessing a boundary; saying so is more useful than a guess.
|
||||||
|
|
||||||
## Unreleased
|
## Unreleased
|
||||||
|
|
||||||
**Inverter B gets its own MQTT device, and inverter A keeps the one it has
|
**Inverter B gets its own MQTT device, and inverter A keeps the one it has
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
name: GoodWe RS485 Controller
|
name: GoodWe RS485 Controller
|
||||||
version: "0.6.0"
|
version: "0.7.0"
|
||||||
slug: goodwe_controller
|
slug: goodwe_controller
|
||||||
description: >-
|
description: >-
|
||||||
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart
|
||||||
|
|||||||
Reference in New Issue
Block a user