SAFETY-86: peak guard outranks the maintenance hold
During a HOLD the holding battery gives what keeps the quarter at the peak aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain (SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the other live batteries may place, so they give first. A site stop still decides alone. The hold ends on its clock even if the level dipped. Below the aim nothing changes (rows identical). Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
513183aba3
commit
ba31e7c8b1
@@ -1669,6 +1669,10 @@ gives more than its drain rate, with one battery too (SAFETY-83).
|
||||
In a cheap window the battery being filled charges and the others only add
|
||||
charge; none gives while it charges. The charge is cut to what keeps the
|
||||
15-minute peak at the limit minus `peak_margin_w` (SAFETY-84).
|
||||
While a full battery rests after its charge (the hold), it gives just enough
|
||||
to keep the 15-minute peak at that aim if the house needs it; with two
|
||||
batteries the other one gives first. The hold still ends on its clock
|
||||
(SAFETY-86).
|
||||
|
||||
#### Capacity-tariff exposure of the grid-following loop
|
||||
|
||||
|
||||