SAFETY-86: peak guard outranks the maintenance hold
checks / unit (pull_request) Successful in 24m17s
infra-pin / fresh (pull_request) Successful in 1s

During a HOLD the holding battery gives what keeps the quarter at the peak
aim. N=1: the peak floor is refiled at P_MAINTENANCE, as for a drain
(SAFETY-83). N>=2: the hold's pin is raised to the floor minus what the
other live batteries may place, so they give first. A site stop still
decides alone. The hold ends on its clock even if the level dipped.
Below the aim nothing changes (rows identical).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-10-01 00:56:34 +02:00
co-authored by Claude Opus 5.5
parent 513183aba3
commit ba31e7c8b1
8 changed files with 473 additions and 13 deletions
@@ -30,6 +30,5 @@ everything. Where the floor is at or below the drain rate nothing changes.
**Not changed.**
- Between the drain rate and the peak aim, the house still imports what the
drain leaves (N=1 behaviour kept by the identity). At N=2 the loop covers it.
- A maintenance HOLD (0 W, 120 min, battery full) still outranks the peak
guard at N=1. Discharging there spends the charge the BMS balances on; it is
an owner question, not this fix.
- A maintenance HOLD (0 W, 120 min, battery full) still outranked the peak
guard at N=1. Fixed by [[SAFETY-86]].
@@ -41,6 +41,6 @@ was fine.
and the battery gives until the quarter is safe. The same sizing would fit
there; that is an owner question, not this fix.
- Outside a cheap window (`hi = 0`, solar only) nothing is filed, at any N.
- A HOLD (SAFETY-86) and the "Battery is not keeping up" alarm (SAFETY-85)
are untouched. In the identity runs that alarm's log line comes as often at
N=2 as at N=1 (2 in 480 cycles).
- A HOLD (later fixed by [[SAFETY-86]]) and the "Battery is not keeping up"
alarm (SAFETY-85) are untouched. In the identity runs that alarm's log line
comes as often at N=2 as at N=1 (2 in 480 cycles).
@@ -0,0 +1,46 @@
# SAFETY-86 - the peak guard outranks the maintenance HOLD
**Status: DECIDED 2026-09-30 (owner).** Follows SAFETY-83's "Not changed"
list. Tests: `test_safety86.py`.
**The defect.** The HOLD (battery resting full after the maintenance charge)
is a SET of 0 W at `P_MAINTENANCE` (60), above the peak floor (`P_PEAK`, 50),
so the floor did not bind. At N=1 a 6500 W house banked 6500 W quarters and
'Load too high' fired (SAFETY-83 rig test, check 4). At N=2 only the other
battery gave: 4500 W against a 3950 W aim (SAFETY-84 rig test, check 6).
**The fix** (`main.py`, `_peak_over_hold()`).
- N=1: during a HOLD a peak floor above 0 W is refiled at `P_MAINTENANCE`, as
for a drain (SAFETY-83). The battery gives the floor; the Why reads "raised
for the peak limit".
- N>=2: the holding battery's pin is raised to the floor minus what the other
live batteries may place (their hard `hi`, or their pin). The others give
first, the holding one only the shortfall. Why this split and not the
allocator's shares: the hold is maintenance and outranks the others' use
(owner order), and the owner rule for an Off battery is the same, "give way
only for the shortfall". A battery Off by its mode (P_MODE, below
maintenance) therefore still gives before the holding one.
- Below the aim nothing changes: the floor is 0 W, the hold is 0 W, the rows
are identical to before (test_safety86.py part 2).
- A site stop (a SET above `P_PEAK`) decides alone: nothing is raised at N>=2,
and the refiled floor at N=1 stays under `P_SAFETY`. If another battery is
pinned to charge (a SAFETY-73 probe) the pin is not raised, so the site is
never split both ways.
- The hold resumes by itself: the rule is evaluated each cycle, so when the
guard lets go the command is 0 W again.
**The level dips below the target: the hold finishes anyway.** The HOLD does
not read the level; it ends on its clock (`maintenance_hold_min`). Topping up
would mean going back to CHARGE, which waits for sun or a cheap window (up to
36 h, `CHARGE_TIMEOUT_MIN`) while the pack keeps the site's one maintenance
slot, so the other battery's cycle waits, and then a new full hold that the
guard can interrupt again. The guard only gives while the quarter is at risk,
and the next monthly cycle balances again. If the owner wants a top-up
instead, it is a change to `maintenance.py`'s HOLD branch, not to this rule.
**Not changed.**
- The peak guard still grades the emptiest battery (SAFETY-32): at N=2 with
B under `peak_soc_floor` the floor is limited and A holds even when it is
full (SAFETY-87).
- "Battery is not keeping up" during maintenance (SAFETY-85), the N=2 charge
flapping (SAFETY-88) and the N=1 charge headroom sizing are untouched.
+4
View File
@@ -1669,6 +1669,10 @@ gives more than its drain rate, with one battery too (SAFETY-83).
In a cheap window the battery being filled charges and the others only add
charge; none gives while it charges. The charge is cut to what keeps the
15-minute peak at the limit minus `peak_margin_w` (SAFETY-84).
While a full battery rests after its charge (the hold), it gives just enough
to keep the 15-minute peak at that aim if the house needs it; with two
batteries the other one gives first. The hold still ends on its clock
(SAFETY-86).
#### Capacity-tariff exposure of the grid-following loop
+1 -1
View File
@@ -79,7 +79,7 @@ P_PEAK = 50 # capacity-tariff peak shaving - costs real money
# The order in effect: safety limits and the SAFETY-73 refusal > the peak
# guard > maintenance > modes > trade > loop. A peak floor above a drain still
# binds: the `drain` site floor at N>=2 (SAFETY-78), refiled at P_MAINTENANCE
# at N=1 (SAFETY-83). Not a maintenance HOLD at N=1 (DECISIONS/SAFETY-83).
# at N=1 (SAFETY-83); over a HOLD, `_peak_over_hold()` (SAFETY-86).
# A cheap-window charge is suspended while the peak guard holds and, at N>=2,
# sized to the quarter's headroom (SAFETY-84).
P_MAINT_SHAPE = 40 # maintenance shaping the loop (charge-only)
+48 -2
View File
@@ -74,7 +74,7 @@ from .hass import HomeAssistant
from .inverter import (LINK_STALE_S, UNIT_A, build_roster,
roster_entries, roster_names)
from .maintenance import (
DRAIN, IDLE, POWER_MOVING, MaintConfig, Maintenance, MaintResult,
DRAIN, HOLD, IDLE, POWER_MOVING, MaintConfig, Maintenance, MaintResult,
arbitrate as maint_arbitrate,
)
from .mqtt import (MODE_CONFIGS_KEY, MODE_LABELS, USE_OFF, USE_ON,
@@ -2533,6 +2533,50 @@ class Controller:
if c.source == peakguard.SOURCE and c.lo > rate:
claims[i] = dataclasses.replace(c, priority=P_MAINTENANCE)
def _peak_over_hold(self, claims, maint_results) -> None:
"""SAFETY-86: a peak floor outranks a maintenance HOLD (0 W).
At N=1 the floor is refiled at P_MAINTENANCE, as for a drain. At N>=2
the holding pack gives only what the others cannot: its pin is raised
to the floor minus what they may place. A site stop still decides
alone. DECISIONS/SAFETY-86-peak-over-hold.md.
"""
hold = {self.actuator_of("maintenance", inv)
for inv, res in zip(self.inverters, maint_results)
if res.phase == HOLD and res.owns_setpoint}
peak = [i for i, c in enumerate(claims)
if c.source == peakguard.SOURCE and c.lo > 0.0]
if not hold or not peak:
return
if len(self.inverters) == 1:
for i in peak:
claims[i] = dataclasses.replace(claims[i],
priority=P_MAINTENANCE)
return
if any(c.kind == SET and c.actuator == ACTUATOR_SITE
and c.priority > P_PEAK for c in claims):
return
live = set(self.live_units())
others = 0.0
for inv in self.inverters:
u = self.actuator_of("maintenance", inv)
if u in hold or u not in live:
continue
b = pre_resolve([c for c in claims if c.actuator == u])
if b.contradiction:
continue
p = allocator.pin_w(b)
if p is not None and p < 0.0:
return # a pack pinned to charge: never split both ways
others += allocator.hi_w(b) if p is None else p
give = max(claims[i].lo for i in peak) - others
if give <= 0.0:
return
for i, c in enumerate(claims):
if c.source == "maintenance" and c.kind == SET \
and c.actuator in hold:
claims[i] = dataclasses.replace(c, value=give)
def _charge_headroom(self, floor: float, claims) -> float:
"""SAFETY-84: at N>=2 a cheap-window charge pulls no more than the
quarter's headroom under the peak aim (`charge_headroom_w()`), so it
@@ -3905,7 +3949,8 @@ class Controller:
# business, not this block's: a maintenance DRAIN or HOLD owns the
# setpoint at P_MAINTENANCE, and a maintenance CHARGE is only ever a
# P_MAINT_SHAPE limit (40), bound by this floor. A floor above the drain
# rate still wins (SAFETY-78 at N>=2, `_peak_over_drain()` at N=1).
# rate still wins (SAFETY-78 at N>=2, `_peak_over_drain()` at N=1), and
# so does a floor over a HOLD (`_peak_over_hold()`, SAFETY-86).
#
# ⚠️ AND IT IS NOT RUN AT ALL WITHOUT P1. `meter_source: off` is the
# legacy single-entity path: there is no telegram stream, so
@@ -4307,6 +4352,7 @@ class Controller:
reason="maintenance drain",
actuator=self.actuator_of("drain")))
self._peak_over_drain(claims, maint_results)
self._peak_over_hold(claims, maint_results)
# --- SAFETY-84: a cheap-window charge is a ceiling over the site ----
charge = self._charge_ceiling(claims)
if charge is not None:
+3 -4
View File
@@ -295,11 +295,10 @@ def store_hold():
_h_rows, _h, _hb = run(6000.0, 2500, 50, 2000, dur=600.0, store=store_hold())
check("a maintenance HOLD at N=1 is not changed (DECISIONS/SAFETY-83, not "
"changed): the battery stays at 0 W with the house over the limit",
check("a maintenance HOLD at N=1 now gives way to the guard too (SAFETY-86, "
"test_safety86.py): the battery gives with the house over the limit",
_h.maints[0].phase == "hold" and _h.peak_guard.engaged
and _h.peak_guard.floor_w > 0.0
and all(cmd(r) == 0.0 for r in _h_rows))
and cmd(_h_rows[-1]) > 0.0 and "limited by peak" in _h_rows[-1][6])
print()
if fails:
+366
View File
@@ -0,0 +1,366 @@
"""Runnable check for SAFETY-86: the peak guard outranks the maintenance HOLD.
`python3 test_safety86.py`
During the HOLD the battery rests full at 0 W (P_MAINTENANCE, above the peak
floor), so the house imported everything and quarters went over the peak
limit. Now the holding battery gives what keeps the quarter at the aim: at N=1
the peak floor is refiled at P_MAINTENANCE, at N>=2 the hold's pin is raised
to what the other batteries cannot give. Drives the REAL Controller
(tools/safety84_identity.py's harness). DECISIONS/SAFETY-86-peak-over-hold.md.
1. N=1, house over the aim: every quarter lands on the aim, the hold goes on,
no 'Load too high'; without the fix the quarter goes over and it fires.
2. Under the aim nothing changes, at N=1 and N=2 (rows identical).
3. N=2, house over the aim: the other battery gives first, the holding one
only the shortfall; with battery modes on and B Off too.
4. A month peak banked above the limit: the aim is that peak - margin.
5. A safety stop still parks everything, and the hold gives again after.
6. The level dips below the target: the hold still ends on its clock.
7. The rule at its boundaries, on claim lists.
Mutations (MUTATION.md, purged copies) are listed in the pull request.
"""
import logging
import os
import sys
import types
HERE = os.path.dirname(os.path.abspath(__file__))
sys.path.insert(0, HERE)
sys.path.insert(0, os.path.join(HERE, "tools"))
logging.disable(logging.WARNING)
import opt11_identity as rig # noqa: E402
import safety84_identity as s84 # noqa: E402
from app import control as _ctl # noqa: E402
from app import packmode # noqa: E402
from app.arbiter import (Claim, P_MAINTENANCE, P_PEAK, P_SAFETY, # noqa
resolve)
from app.main import Controller # noqa: E402
from app.maintenance import DRAIN, HOLD, IDLE, MaintResult # noqa: E402
from app.store import unit_key # noqa: E402
fails = []
A, B = "inverter-a", "inverter-b"
AIM = 3450.0 # peak_cap_w 3500 - peak_margin_w 50
TOL = 10.0 # W over the aim a banked quarter may show (SAFETY-81)
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
def store_hold(n, b_off=False):
"""A store with battery A in its HOLD from the first cycle."""
s = rig._Store()
for k in ("phase", "phase_started"):
s.data[k if n == 1 else unit_key(A, k)] = (
"hold" if k == "phase" else rig.BASE.isoformat())
if b_off:
s.data[unit_key(B, packmode.USE_KEY)] = False
return s
def full(u, t):
"""A rests full; B is half full."""
return 99.0 if u == "a" else 60.0
def run(house, n, *, hold_min=600, b_off=False, extra=None, **kw):
kw.setdefault("soc", full)
kw.setdefault("dur", 2700.0)
return s84.run(n, load=house if callable(house) else lambda t: house,
cheap=False, store=store_hold(n, b_off),
extra=dict({"maintenance_hold_min": hold_min},
**(extra or {})), **kw)
def without_fix(fn):
real = Controller._peak_over_hold
Controller._peak_over_hold = lambda self, claims, results: None
try:
return fn()
finally:
Controller._peak_over_hold = real
def cmd(r):
return dict(r[2])
def banked(c):
return [b.offtake_avg_w for b in c.p1.blocks]
def on_aim(c, aim=AIM):
b = banked(c)
return len(b) >= 2 and all(aim - TOL <= v <= aim + TOL for v in b)
def alarmed(c):
"""Did SAFETY-81's 'Load too high' alarm fire on this run?"""
return any("PEAK_GUARD_SATURATED" in e for e in c.events)
def refused(rows):
return sum(1 for r in rows if r[7] and "REFUSED" in r[7])
def peak_prio(r):
return [c[1] for c in r[-1][0] if c[0] == "peak"]
def hold_pin(r):
return [c[3] for c in r[-1][0] if c[0] == "maintenance" and c[2] == "set"]
# ============================================================================ #
print("1. N=1: a house over the aim during the HOLD")
N1 = {h: run(h, 1) for h in (5000.0, 6500.0, 7000.0)}
N1_OLD = {h: without_fix(lambda: run(h, 1)) for h in N1}
for h in N1:
print(f" house {h:.0f}: banked {[round(v) for v in banked(N1[h][1])]} W"
f" (before the fix {[round(v) for v in banked(N1_OLD[h][1])]} W), "
f"last {N1[h][0][-1][6]}")
check("⭐ every quarter lands on the aim (3450 W) for a 5000, 6500 and "
"7000 W house, and 'Load too high' never fires",
all(on_aim(c) and not alarmed(c) for _r, c in N1.values()))
check("...the battery gives, raised for the peak limit, and stays in its "
"HOLD: the phase is hold and the claim still says so",
all(c.maints[0].phase == HOLD and cmd(rows[-1])["a"] > 1000.0
and "limited by peak" in rows[-1][6]
and c.why_words.endswith("raised for the peak limit")
for rows, c in N1.values()))
check("non-vacuous: without the fix the battery sits at 0 W, the quarter "
"banks the whole house and 'Load too high' fires",
all(all(cmd(r)["a"] == 0.0 for r in rows) and min(banked(c)) >= h - 1
and alarmed(c) for h, (rows, c) in N1_OLD.items()))
def hob(t):
"""A 6000 W house with a 5 s spike to 11000 W every 150 s."""
return 11000.0 if t % 150 < 5 else 6000.0
_sp_rows, _sp = run(hob, 1)
check("...and 5 s spikes that saturate the guard for a cycle do not fire it "
"(SAFETY-81's 10 s hold)",
any(r[-1][1] and r[-1][1][1] >= 5000.0 for r in _sp_rows)
and not alarmed(_sp))
# ============================================================================ #
print("\n2. under the aim the HOLD is as before")
BELOW = {(n, h): (run(h, n, dur=1800.0),
without_fix(lambda: run(h, n, dur=1800.0)))
for n, h in ((1, 1200.0), (1, 3000.0), (1, -1500.0),
(2, 1500.0), (2, 3000.0), (2, 5000.0))}
check("⭐ N=1 at a 1200 W and 3000 W house and a 1500 W surplus, N=2 at "
"1500, 3000 and 5000 W (B covers it): battery A is at 0 W on every "
"cycle and every row equals the run without the fix",
all(all(cmd(r)["a"] == 0.0 for r in new[0]) and new[0] == old[0]
for new, old in BELOW.values()))
check("...and the peak claim stays at P_PEAK on every cycle",
all(p == P_PEAK for new, _o in BELOW.values() for r in new[0]
for p in peak_prio(r)))
# ============================================================================ #
print("\n3. N=2: the other battery gives first, the holding one the rest")
N2 = {h: run(h, 2) for h in (6500.0, 7000.0)}
N2_OLD = {h: without_fix(lambda: run(h, 2)) for h in N2}
for h, (rows, c) in N2.items():
print(f" house {h:.0f}: banked {[round(v) for v in banked(c)]} W "
f"(before the fix {[round(v) for v in banked(N2_OLD[h][1])]} W), "
f"last {rows[-1][2]}")
check("⭐ house 6500 and 7000 W, B at most 2500 W: every quarter lands on "
"the aim, nothing is refused or split both ways, no 'Load too high'",
all(on_aim(c) and refused(rows) == 0 and not alarmed(c)
and all(cmd(r)["a"] * cmd(r)["b"] >= 0.0 for r in rows)
for rows, c in N2.values()))
_gives = [r for rows, _c in N2.values() for r in rows if cmd(r)["a"] > 0.0]
check("⭐ A gives only the shortfall: on every cycle A gives, B is at its "
"2500 W and A's pin is the guard's floor minus 2500 W",
len(_gives) > 500
and all(cmd(r)["b"] == 2500.0 and hold_pin(r)
and abs(hold_pin(r)[0] - (r[-1][1][1] - 2500.0)) < 1e-6
for r in _gives))
check("...A stays in its HOLD, and its last command is the shortfall "
"(6500 - 3450 - 2500 = 550 W, give or take the meter's 1 W)",
all(c.maints[0].phase == HOLD for _r, c in N2.values())
and 540.0 <= cmd(N2[6500.0][0][-1])["a"] <= 560.0)
check("non-vacuous: without the fix A sits at 0 W, the quarter goes over "
"the limit and 'Load too high' fires",
all(all(cmd(r)["a"] == 0.0 for r in rows) and max(banked(c)) > 3900.0
and alarmed(c) for rows, c in N2_OLD.values()))
_off_rows, _off = run(6500.0, 2, b_off=True,
extra={"battery_modes_enabled": True})
print(f" B Off, house 6500: banked {[round(v) for v in banked(_off)]} W, "
f"last {_off_rows[-1][2]}")
check("⭐ battery modes on, B Off: the Off battery still gives before the "
"holding one (maintenance outranks a mode), the quarter lands on the "
"aim, nothing refused",
on_aim(_off) and cmd(_off_rows[-1])["b"] == 2500.0
and 540.0 <= cmd(_off_rows[-1])["a"] <= 560.0
and refused(_off_rows) == 0 and not alarmed(_off))
# ============================================================================ #
print("\n4. a month peak banked above the limit")
BANK = {n: (run(6500.0, n, month_peak=4000.0),
without_fix(lambda: run(6500.0, n, month_peak=4000.0)))
for n in (1, 2)}
for n, (new, old) in BANK.items():
print(f" N={n} house 6500, month peak 4000: banked "
f"{[round(v) for v in banked(new[1])]} W (before the fix "
f"{[round(v) for v in banked(old[1])]} W)")
check("⭐ under a month peak of 4000 W the aim is 3950 W (peak - margin), "
"at N=1 and N=2, and no 'Load too high'",
all(on_aim(new[1], 3950.0) and not alarmed(new[1])
for new, _old in BANK.values()))
check("non-vacuous: before the fix N=1 banks the whole house and N=2 banks "
"4000 W, over that aim",
min(banked(BANK[1][1][1])) >= 6499.0
and min(banked(BANK[2][1][1])) >= 3999.0)
# ============================================================================ #
print("\n5. a safety stop still wins")
def blind_at(t0, t1):
"""A's power reading is missing from `t0` to `t1`: a site safety SET."""
def before(c, t):
s84.feed(False)(c, t)
if not getattr(c.hass, "_blind", False):
real = c.hass.number
async def number(e, invert=False):
if e == "sensor.batt_a" and t0 <= c.hass.t < t1:
return None
return await real(e, invert)
c.hass.number, c.hass._blind = number, True
return before
STOP = {n: run(6500.0, n, dur=900.0, before=blind_at(300.0, 600.0))
for n in (1, 2)}
for n, (rows, _c) in STOP.items():
print(f" N={n} reading lost 300-600 s: at {rows[100][0]:.0f} s "
f"{rows[100][2]}, {rows[100][6]}; after {rows[-1][2]}")
check("⭐ with a reading gone the safety SET parks every battery at 0 W, at "
"N=1 and N=2, with nothing refused",
all(all(v == 0.0 for r in rows if 330.0 <= r[0] < 600.0
for v in cmd(r).values())
and any(r[6].startswith("safety -> 0 W") for r in rows)
and refused(rows) == 0 for rows, _c in STOP.values()))
check("...the hold gave before the stop and gives again after it",
all(cmd(rows[50])["a"] > 0.0 and cmd(rows[-1])["a"] > 0.0
for rows, _c in STOP.values()))
# ============================================================================ #
print("\n6. the level dips below the hold's target")
def draining(u, t):
"""A's level falls 1 % a minute from 99 % (set, not integrated); B 60 %."""
return max(20.0, 99.0 - t / 60.0) if u == "a" else 60.0
DIP = {n: run(6500.0, n, hold_min=30, dur=2400.0, soc=draining)
for n in (1, 2)}
for n, (rows, c) in DIP.items():
print(f" N={n}: phases {sorted({tuple(x[-1][3]) for x in rows})}, "
f"last event {[e for e in c.events if 'maintenance' in e][:1]}")
check("⭐ the level falls from 99 % to 70 % while the hold gives, and "
"the hold still ends on its 30 min clock: HOLD -> IDLE, cycle "
"COMPLETE, never back to CHARGE, at N=1 and N=2",
all(c.maints[0].phase == IDLE
and any("cycle COMPLETE" in e for e in c.events)
and {x[-1][3][0] for x in rows} == {HOLD, IDLE}
and all(x[-1][3][0] == HOLD for x in rows if x[0] < 1795.0)
for rows, c in DIP.values()))
check("...the hold gave on the way (the level really dipped)",
all(any(cmd(r)["a"] > 0.0 for r in rows if r[0] < 1795.0)
for rows, _c in DIP.values()))
# ============================================================================ #
print("\n7. the rule at its boundaries")
_c = run(1500.0, 2, dur=10.0)[1]
_c1 = run(1500.0, 1, dur=10.0)[1]
HOLDING = [MaintResult(HOLD, True, 0.0, False, []),
MaintResult(IDLE, False, None, False, [])]
def pin_after(floor, *extra, live=(A, B), results=HOLDING, c=_c):
fake = types.SimpleNamespace(inverters=c.inverters,
actuator_of=c.actuator_of,
live_units=lambda: tuple(live))
cl = [Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=A),
Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=B),
Claim.set("maintenance", P_MAINTENANCE, 0.0, HOLD, actuator=A),
Claim.limit("peak", P_PEAK, lo=floor, reason="quarter peak"),
*extra]
Controller._peak_over_hold(fake, cl, results)
return next((x.value for x in cl
if x.source == "maintenance" and x.kind == "set"), None), cl
check("⭐ at N=2 a floor under or at B's 2500 W leaves A at 0 W (never "
"charging); 0.5 W above it raises A's pin to 0.5 W",
pin_after(1000.0)[0] == 0.0 and pin_after(2500.0)[0] == 0.0
and pin_after(2500.5)[0] == 0.5)
check("⭐ B not live, contradicting itself, or refusing to give: A gives the "
"whole floor",
pin_after(2000.0, live=(A,))[0] == 2000.0
and pin_after(2000.0, Claim.limit("pack", P_SAFETY, 10.0, -10.0,
actuator=B))[0] == 2000.0
and pin_after(2000.0, Claim.limit("refused", P_SAFETY, hi=0.0,
actuator=B))[0] == 2000.0)
_probe = _ctl.PROBE_W
check("⭐ B probing: giving counts its probe (A gives the rest), charging "
"leaves A at 0 W so the site is never split both ways",
pin_after(2000.0, Claim.set("refused", P_SAFETY, _probe, "probe",
actuator=B))[0] == 2000.0 - _probe
and pin_after(2000.0, Claim.set("refused", P_SAFETY, -_probe, "probe",
actuator=B))[0] == 0.0)
_p, _cl = pin_after(4000.0, Claim.set("safety", P_SAFETY, 0.0,
"inputs missing"))
check("⭐ a site safety SET: A stays at 0 W and the site resolves to 0 W; "
"a unit safety SET on B does not stop A giving",
_p == 0.0 and resolve(_cl, units=(A, B), live={A, B}).target_w == 0.0
and pin_after(3000.0, Claim.set("failsafe", P_SAFETY, 0.0,
actuator=B))[0] == 3000.0)
check("only a HOLD: a DRAIN pin or an idle pack is not raised",
pin_after(4000.0, results=[MaintResult(DRAIN, True, 0.0, False, []),
HOLDING[1]])[0] == 0.0
and pin_after(4000.0, results=[HOLDING[1], HOLDING[1]])[0] == 0.0)
def refile(lo, results=(HOLDING[0],)):
fake = types.SimpleNamespace(inverters=_c1.inverters,
actuator_of=_c1.actuator_of)
cl = [Claim.set("maintenance", P_MAINTENANCE, 0.0, HOLD),
Claim.limit("peak", P_PEAK, lo=lo, reason="quarter peak")]
Controller._peak_over_hold(fake, cl, list(results))
return cl
check("⭐ at N=1 a floor of 0 W stays at P_PEAK, 0.5 W is refiled at "
"P_MAINTENANCE, and a blind claim (a ceiling only) is not refiled",
refile(0.0)[1].priority == P_PEAK
and refile(0.5)[1].priority == P_MAINTENANCE
and refile(float("-inf"))[1].priority == P_PEAK)
_stop = refile(3000.0) + [Claim.set("safety", P_SAFETY, 0.0,
"inputs missing")]
check("⭐ at N=1 a refiled floor stays under a safety SET: 0 W",
resolve(_stop).target_w == 0.0)
check("at N=1 outside a HOLD the claim is not touched by this rule",
refile(3000.0, (MaintResult(IDLE, False, None, False, []),))[1]
.priority == P_PEAK)
print()
if fails:
print(f"{len(fails)} FAILED: " + ", ".join(fails))
sys.exit(1)
print("all SAFETY-86 checks passed")