EV-20 SPIKE-06 re-check: a stuck verdict does not hold Solar while no own current may stand (C14)
The exemption now applies whenever Solar is not live (also just after Solar is chosen under a verdict Manual's refusals left), so Solar writes its 0 A over the other current first and then the start rule runs. EV-13 T14 [8 A], T17 and T18 now assert that the energy meter does not flag the frozen figure (PM accepted the trade-off); T14 [6 A] that it flags at +57 s. Co-Authored-By: Claude <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
@@ -658,8 +658,13 @@ for TO_A in (8, 6):
|
||||
check(f"T14 [{TO_A} A] ...the write was accepted", res[0][2] is True)
|
||||
if TO_A == 6:
|
||||
check(f"T14 [6 A] the energy meter flags the frozen figure (EV-18) "
|
||||
f"within 120 s of the write (+{rel})",
|
||||
rel is not None and rel <= 120)
|
||||
f"at about +57 s after the write (+{rel})",
|
||||
rel is not None and 50 <= rel <= 65)
|
||||
else:
|
||||
# The frozen figure is exactly 2x the real draw: CORR_RATIO 0.5 is
|
||||
# not undercut, so EV-18 never flags it (PM accepted, SPIKE-06).
|
||||
check(f"T14 [8 A] the energy meter does NOT flag the frozen figure "
|
||||
f"(+{rel}); only the read-back cap bounds it", rel is None)
|
||||
|
||||
|
||||
async def t17():
|
||||
@@ -681,6 +686,9 @@ w, res, cs = run(t17())
|
||||
T17_S = contra_report("T17 live refusals, then an ACCEPTED write to 12 A "
|
||||
"under a frozen power", res[-1][0], cs,
|
||||
12 * CH.CEILING_V * 3)
|
||||
check(f"T17 the energy meter does NOT flag the frozen figure (+{T17_S}); "
|
||||
f"only the read-back cap bounds it (PM accepted, SPIKE-06)",
|
||||
T17_S is None)
|
||||
check("T17 ...the last write was accepted, after the refusals",
|
||||
res[-1][2] is True and res[0][2] is False)
|
||||
|
||||
@@ -704,6 +712,9 @@ w, res, cs = run(t18())
|
||||
T18_S = contra_report("T18 an ACCEPTED write to 12 A under a frozen power, a "
|
||||
"refusal 20 s later", res[0][0], cs,
|
||||
12 * CH.CEILING_V * 3)
|
||||
check(f"T18 the energy meter does NOT flag the frozen figure (+{T18_S}); "
|
||||
f"only the read-back cap bounds it (PM accepted, SPIKE-06)",
|
||||
T18_S is None)
|
||||
check("T18 ...the second write was refused", len(res) >= 2
|
||||
and res[1][2] is False)
|
||||
|
||||
|
||||
Reference in New Issue
Block a user