EV-20 SPIKE-06 re-check: a stuck verdict does not hold Solar while no own current may stand (C14)
The exemption now applies whenever Solar is not live (also just after Solar is chosen under a verdict Manual's refusals left), so Solar writes its 0 A over the other current first and then the start rule runs. EV-13 T14 [8 A], T17 and T18 now assert that the energy meter does not flag the frozen figure (PM accepted the trade-off); T14 [6 A] that it flags at +57 s. Co-Authored-By: Claude <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
@@ -126,9 +126,11 @@ one small set of facts and derives every path from them:
|
||||
- A frozen POWER under an accepted write (the read-back moves) is no longer
|
||||
judged here: the energy meter (EV-18 `contradicted`) and the read-back
|
||||
cap on the trusted figure judge it.
|
||||
- **Solar after a stuck verdict (C12):** once Solar's own 0 A stands
|
||||
(written and taken), a stuck verdict no longer holds the car at 0 A; the
|
||||
start rule runs. Its write moves the reading (the verdict clears) or is
|
||||
- **Solar after a stuck verdict (C12, C14):** while no current of Solar's
|
||||
own may stand (its own 0 A stands, or Solar was just chosen), a stuck
|
||||
verdict no longer holds Solar: it writes its 0 A first over a current that
|
||||
is not its own, then the start rule runs; at most MAX_TRIES starts per
|
||||
verdict, then CHARGER_REFUSED until Solar is pressed. Its write moves the reading (the verdict clears) or is
|
||||
refused (EV-04's retries, then CHARGER_REFUSED).
|
||||
- **No amp ping-pong:** after a step down, a step back up needs
|
||||
`UP_HYST_W` (100 W) past the amp boundary.
|
||||
|
||||