SAFETY-87 review: maintenance pins beside a held battery
A draining battery that may still give is raised from its drain rate towards its rating for the peak floor while another battery is held (peak > drain); before, the floor's rest landed on the held battery. In a HOLD, a held battery's own pin counts among the others: a held drain no longer over-places the site, and a held charge probe no longer parks it. Tests: test_safety87.py part 10 (drain beside a held battery, N=3 HOLD, unknown cut-out and unread level at N=3, a stopping row outranks the running peak alarm). DECISIONS entry updated, incl. the modes-on exception. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
@@ -44,8 +44,8 @@ import opt11_identity as rig # noqa: E402
|
||||
import safety84_identity as s84 # noqa: E402
|
||||
import safety87_identity as s87 # noqa: E402
|
||||
from app import messages, packmode, peakguard # noqa: E402
|
||||
from app.arbiter import (Claim, P_MODE, P_PEAK, P_SAFETY, # noqa: E402
|
||||
UnitBounds, resolve)
|
||||
from app.arbiter import (Claim, P_MAINTENANCE, P_MODE, P_PEAK, # noqa: E402
|
||||
P_SAFETY, UnitBounds, resolve)
|
||||
from app.main import Controller # noqa: E402
|
||||
from app.maintenance import DRAIN, HOLD, IDLE, MaintResult # noqa: E402
|
||||
from app.store import unit_key # noqa: E402
|
||||
@@ -540,6 +540,122 @@ check("⭐ every N=1 digest (claims, commands, the guard's decision and the "
|
||||
"charge and a HOLD, and under a banked peak",
|
||||
_now == PINNED)
|
||||
|
||||
# ============================================================================ #
|
||||
print("\n10. review: maintenance pins beside a held battery, N=3, the page")
|
||||
|
||||
|
||||
def _drain_store():
|
||||
s = rig._Store()
|
||||
s.data[unit_key(B, "phase")] = DRAIN
|
||||
s.data[unit_key(B, "phase_started")] = rig.BASE.isoformat()
|
||||
s.data[unit_key(A, "last_completed")] = rig.BASE.isoformat()
|
||||
return s
|
||||
|
||||
|
||||
def _drain_run():
|
||||
return run(8000.0, IDLE, {"a": 15.0, "b": 60.0}, store=_drain_store(),
|
||||
dur=900.0)
|
||||
|
||||
|
||||
DR = _drain_run()
|
||||
_real_dor = Controller._drain_over_reserve
|
||||
Controller._drain_over_reserve = lambda self, claims, results: None
|
||||
try:
|
||||
DR_OLD = _drain_run()
|
||||
finally:
|
||||
Controller._drain_over_reserve = _real_dor
|
||||
|
||||
|
||||
def _a_for_peak(rows):
|
||||
"""A's command on the cycles where the site target is the peak floor
|
||||
and B alone (2500 W) could place it."""
|
||||
return [cmd(r)["a"] for r in rows
|
||||
if r[-1][1] and r[-1][1][1] and r[1] <= 2500.0
|
||||
and abs(r[1] - r[-1][1][1]) < 1.0]
|
||||
|
||||
|
||||
print(f" B draining, A held: A for the peak {_a_for_peak(DR[0])[:4]}, "
|
||||
f"without the raise {_a_for_peak(DR_OLD[0])[:4]}")
|
||||
check("⭐ B draining (2000 W pin) while A is held: B is raised to its rating "
|
||||
"for the peak floor, so A gives nothing for it (peak > drain)",
|
||||
DR[1].maints[1].phase == DRAIN and _a_for_peak(DR[0])
|
||||
and all(a <= 0.0 for a in _a_for_peak(DR[0])))
|
||||
check("non-vacuous: without the raise A gave the floor's rest above B's pin",
|
||||
any(a > 0.0 for a in _a_for_peak(DR_OLD[0])))
|
||||
|
||||
|
||||
def _stub(names, reserve, live=None):
|
||||
"""A Controller stand-in for the pin rules, on SIMULATED units."""
|
||||
s = types.SimpleNamespace(
|
||||
inverters=[types.SimpleNamespace(name=n) for n in names],
|
||||
actuator_of=lambda src, inv=None: inv.name,
|
||||
live_units=lambda: tuple(live or names),
|
||||
_peak_reserve=lambda: frozenset(reserve))
|
||||
s._held_pin = lambda cl, u: Controller._held_pin(s, cl, u)
|
||||
return s
|
||||
|
||||
|
||||
def _hold(floor, names, reserve, extra=(), results=None):
|
||||
"""`_peak_over_hold()`: x HOLDs; returns (x's pin, resolved shares)."""
|
||||
s = _stub(names, reserve)
|
||||
cl = [Claim.limit("supervised", P_SAFETY, -2500.0, 2500.0, actuator=n)
|
||||
for n in names]
|
||||
cl += [Claim.set("maintenance", P_MAINTENANCE, 0.0, HOLD, actuator="x"),
|
||||
Claim.limit("peak", P_PEAK, lo=floor, reason="quarter peak"),
|
||||
*extra]
|
||||
res = results or ([MaintResult(HOLD, True, 0.0, False, [])]
|
||||
+ [MaintResult(IDLE, False, None, False, [])]
|
||||
* (len(names) - 1))
|
||||
hi = Controller._peak_over_hold(s, cl, res)
|
||||
if hi is not None:
|
||||
cl.append(Claim.limit("hold", P_MAINTENANCE, hi=hi))
|
||||
r = resolve(cl + [Claim.set("loop", 10, floor)], units=tuple(names),
|
||||
live=set(names), reserve=reserve)
|
||||
pin = next((c.value for c in cl
|
||||
if c.source == "maintenance" and c.actuator == "x"), None)
|
||||
return pin, {u: round(v) for u, v in r.shares.items()}
|
||||
|
||||
|
||||
_h3 = _hold(3000.0, ("x", "y", "z"), {"z"})
|
||||
_h3b = _hold(2000.0, ("x", "y", "z"), {"z"})
|
||||
print(f" N=3 HOLD x, y able, z held: floor 3000 {_h3}, 2000 {_h3b}")
|
||||
check("⭐ HOLD at N=3 with one held: the able battery gives first, the "
|
||||
"holding one the rest (3000 -> y 2500, x 500), the held one nothing",
|
||||
_h3 == (500.0, {"x": 500, "y": 2500, "z": 0})
|
||||
and _h3b == (0.0, {"x": 0, "y": 2000, "z": 0}))
|
||||
_hd = _hold(2000.0, ("x", "z"), {"z"},
|
||||
(Claim.set("maintenance", P_MAINTENANCE, 1500.0, DRAIN,
|
||||
actuator="z"),),
|
||||
[MaintResult(HOLD, True, 0.0, False, []),
|
||||
MaintResult(DRAIN, True, 1500.0, False, [])])
|
||||
_hp = _hold(2000.0, ("x", "z"), {"z"},
|
||||
(Claim.set("refused", P_SAFETY, -50.0, "probe", actuator="z"),))
|
||||
print(f" held z draining 1500: {_hd}; held z charge probe: {_hp}")
|
||||
check("⭐ a held battery's own pin counts: draining 1500 W, the hold gives "
|
||||
"only the 500 W rest (no over-placement); a charge probe leaves the "
|
||||
"hold at 0 W (never split both ways, no park)",
|
||||
_hd == (500.0, {"x": 500, "z": 1500}) and _hp[0] == 0.0)
|
||||
|
||||
_unk = three((60.0, 60.0, 60.0), (10, None, 10))
|
||||
_unr = three((60.0, None, 60.0), (10, 10, 10))
|
||||
check("⭐ N=3: an unknown cut-out or an unread level holds that battery "
|
||||
"only; the two others are asked for the need",
|
||||
_unk.held == ("y",) and not _unk.floor_limited
|
||||
and _unk.floor_w == 2000.0 and _unr.held == ("y",)
|
||||
and not _unr.floor_limited and _unr.floor_w == 2000.0)
|
||||
|
||||
_stop_row = {"ok": False, "warn": False, "id": "meter", "text": "Meter down."}
|
||||
_peak_rows = [r for r in _c65.checks() if r.get("id") == "peak_guard"]
|
||||
_c65.checks = lambda: _peak_rows[:1] + [_stop_row]
|
||||
_both = _c65.status_payload()
|
||||
del _c65.checks
|
||||
check("⭐ a row that stops control outranks the running peak alarm: the "
|
||||
"banner says 'Not ready' for it and the Home page shows the hold",
|
||||
len(_peak_rows) == 1 and _peak_rows[0].get("runs")
|
||||
and _both["banner"].startswith(messages.NOT_READY)
|
||||
and "Meter down" in _both["banner"]
|
||||
and "until the alarm clears" in json.dumps(_both, ensure_ascii=False))
|
||||
|
||||
print()
|
||||
if fails:
|
||||
print(f"{len(fails)} FAILED: " + ", ".join(fails))
|
||||
|
||||
Reference in New Issue