SAFETY-126 round 2: state what the 10 W tolerance costs; test the latch reset
Text only (DECISIONS, DOCS, CHANGELOG): a step load alarms on the same cycle as before; a steadily rising load alarms a little later; with peak_margin_w 0 a period can end up to 10 W over the limit without this alarm, as for 'Load too high' (SAFETY-81). Owner accepted 2026-10-31. test_safety126.py part 2: after a real overrun ends, _peak_landing()'s latch is reset and the night's later landings are quiet (review F3). Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
8e2463bc32
commit
a66a7f1a0f
@@ -25,16 +25,21 @@ no "Battery stopped limiting the peak" event hint. The claim, the floor and the
|
||||
commands are unchanged.
|
||||
|
||||
**Still alarms.** House load the batteries cannot cover under the reserve:
|
||||
the period would end over the aim with the batteries at 0 W, so the alarm
|
||||
fires on the same cycle as before (both under the reserve; a 6 500 W house
|
||||
during the night charge). SAFETY-87's case (others able, graded on the limit
|
||||
for `ALARM_HOLD_S`) and SAFETY-81's 'Load too high' notification are unchanged.
|
||||
A period heading at most 10 W over the aim no longer alarms with nothing able
|
||||
to give. That is SAFETY-81's landing tolerance. `misses_aim()` takes the house
|
||||
as meter plus batteries, so an export nets off. `decide()`'s projection counts
|
||||
offtake only. So a re-alarm while the loop's draw on held batteries covers the
|
||||
house with some export, and the period lands under the aim, is gone too
|
||||
(test_safety126.py part 2, modes off: 2 notifications, was 4).
|
||||
the period would end over the aim with the batteries at 0 W. A step load
|
||||
alarms on the same cycle as before. SAFETY-87's case and SAFETY-81's 'Load too
|
||||
high' notification are unchanged.
|
||||
|
||||
**What the 10 W tolerance costs** (review, owner accepted 2026-10-31):
|
||||
- A steadily rising load alarms a little later, once the projected miss passes
|
||||
10 W (3 000 -> 4 000 W over 45 min: 56 s later). With the default 50 W
|
||||
margin the alarm still comes before the limit.
|
||||
- With `peak_margin_w` 0, a period can end up to 10 W over the limit without
|
||||
this alarm, the tolerance 'Load too high' already accepts (SAFETY-81).
|
||||
|
||||
`misses_aim()` takes the house as meter plus batteries, so an export nets
|
||||
off (`decide()`'s projection counts offtake only). A re-alarm while the loop's
|
||||
draw on held batteries covers the house is gone too (test_safety126.py part 2,
|
||||
modes off: 2 notifications, was 4).
|
||||
|
||||
**Not changed.** The one-cycle floor itself: at a period's last instant the
|
||||
guard still asks an able battery for its rating, or stops a charge, for a
|
||||
|
||||
Reference in New Issue