SAFETY-126 round 2: state what the 10 W tolerance costs; test the latch reset
Text only (DECISIONS, DOCS, CHANGELOG): a step load alarms on the same cycle as before; a steadily rising load alarms a little later; with peak_margin_w 0 a period can end up to 10 W over the limit without this alarm, as for 'Load too high' (SAFETY-81). Owner accepted 2026-10-31. test_safety126.py part 2: after a real overrun ends, _peak_landing()'s latch is reset and the night's later landings are quiet (review F3). Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
8e2463bc32
commit
a66a7f1a0f
@@ -4,7 +4,7 @@
|
||||
|
||||
### Not in a release yet
|
||||
|
||||
- The night grid charge no longer raises "Battery stopped limiting the peak" when the 15-minute period stays on the aim ([[SAFETY-126]]).
|
||||
- The night grid charge no longer raises "Battery stopped limiting the peak" when the 15-minute period stays on the aim. A steadily rising load now alarms a little later, and with a peak margin of 0 a period can end up to 10 W over the limit without this alarm ([[SAFETY-126]]).
|
||||
|
||||
**A patch bump: one fix for charging from the grid under the peak limit, and no option changes.**
|
||||
No option was added, removed or renamed, and no default changed (86 options).
|
||||
|
||||