SAFETY-90: the peak guard goes on after a P1 meter gap
A meter gap past meter_max_age_s left seconds the quarter average never counted, so the guard was blind for the rest of the quarter (rig case 7b: 3964.8 W against a 3450 W aim). Once readings are back, the missed seconds now count at the higher of the limit and the import seen just before and just after the gap with the batteries at 0 W (peakguard.gap_w/fill_gaps); the gap's first meter_max_age_s is topped up to that too. Seconds before the add-on's first reading count at the aim, and the page says part of the period was not measured (EN/NL). The bill record is unchanged; no option. DECISIONS/SAFETY-90-peak-guard-after-a-gap.md, test_safety90.py. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -347,6 +347,7 @@
|
||||
"step_in": "De batterijen springen bij boven {kw}.",
|
||||
"step_in_would": "De batterijen zouden bijspringen boven {kw}.",
|
||||
"period": "Dit kwartier gaat richting {kw}.",
|
||||
"period_unmeasured": "Een deel van dit kwartier is niet gemeten.",
|
||||
"prices": {"now": "Prijs nu {eur} per kWh, alles inbegrepen.", "today": "Vandaag: laagste {lo} om {lo_at}, hoogste {hi} om {hi_at}.", "none": "Geen prijzen voor vandaag."},
|
||||
"tomorrow": {"known": "De prijzen van morgen zijn binnen.", "unknown": "De prijzen van morgen komen meestal na 13:00."},
|
||||
"region": {"preset": "Heffingen en btw: {region}, cijfers van {year}.", "own": "Heffingen en btw: uw eigen bedrag."},
|
||||
|
||||
Reference in New Issue