SAFETY-90: the peak guard goes on after a P1 meter gap
checks / unit (pull_request) Successful in 31m10s
infra-pin / fresh (pull_request) Successful in 1s

A meter gap past meter_max_age_s left seconds the quarter average never
counted, so the guard was blind for the rest of the quarter (rig case 7b:
3964.8 W against a 3450 W aim). Once readings are back, the missed seconds
now count at the higher of the limit and the import seen just before and
just after the gap with the batteries at 0 W (peakguard.gap_w/fill_gaps);
the gap's first meter_max_age_s is topped up to that too. Seconds before
the add-on's first reading count at the aim, and the page says part of the
period was not measured (EN/NL). The bill record is unchanged; no option.

DECISIONS/SAFETY-90-peak-guard-after-a-gap.md, test_safety90.py.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Claude (SAFETY-90 dev)
2026-10-05 11:46:58 +02:00
parent 3ed3302d2f
commit 9d3fbe1be9
10 changed files with 656 additions and 7 deletions
+72 -1
View File
@@ -947,6 +947,16 @@ class Controller:
# SAFETY-81: what the alarm is graded on, beside the guard's decision.
self._peak_proj = None
self._peak_batt_prev = None
# SAFETY-90: what a meter gap is counted at (`_fill_peak_gaps()`).
self._gap_seen_w = None
self._gap_w = None
self._gap_block = None
self._gap_filled_s = 0.0
self._gap_held_ws = 0.0
self._gap_pre = None
self._unseen = None
self.peak_gap_s = 0.0
self.peak_unmeasured_s = 0.0
self._peak_alarm_block = None
self._peak_high_since = None
self._peak_floor_limited = False
@@ -2693,6 +2703,58 @@ class Controller:
lo=p, reason=c.reason,
actuator=u)
def _fill_peak_gaps(self, proj, now, reading):
"""SAFETY-90: `proj` with a meter gap's uncounted seconds counted at
`peakguard.gap_w()` of the imports seen just before and just after it,
and those before this run's first reading at the aim (shown as not
measured). DECISIONS/SAFETY-90-peak-guard-after-a-gap.md."""
self.peak_gap_s = self.peak_unmeasured_s = 0.0
avg = self.p1.averager
since = avg.held_since
if proj is None or proj.block_start is None or since is None:
return proj
if self._unseen is None and self.p1.last is not None:
self._unseen = (proj.block_start, max(0.0, (
since - proj.block_start).total_seconds() - avg.elapsed_s))
seen = (None if self.grid is None or self.site_batt_w is None
else float(self.grid) + max(0.0, float(self.site_batt_w)))
if proj.block_start != self._gap_block:
self._gap_block, self._gap_w = proj.block_start, None
self._gap_filled_s = self._gap_held_ws = 0.0
cap = float(self.o.get("peak_cap_w", 3500))
ceiling = peakguard.quarter_ceiling_w(cap, reading)[0]
kw = dict(tail_s=(now - since).total_seconds(),
max_hold_s=avg.max_hold_s,
unseen_s=(self._unseen[1] if self._unseen is not None
and self._unseen[0] == proj.block_start else 0.0),
unseen_w=peakguard.quarter_target_w(
cap, self.peak_margin_w, reading))
_p, gap_s, _u = peakguard.fill_gaps(proj, gap_w=0.0, **kw)
if gap_s > self._gap_filled_s + peakguard.GAP_TOL_S:
self._gap_w = peakguard.gap_w(ceiling, self._gap_w,
self._gap_seen_w, seen)
if self._gap_pre is not None:
# The averager credited the gap's first max_hold_s at the
# reading before it; top that part up to gap_w as well.
s0, g0 = self._gap_pre
h = (min(s0 + timedelta(seconds=avg.max_hold_s), since)
- max(s0, proj.block_start)).total_seconds()
self._gap_held_ws += max(0.0, h) * max(
0.0, self._gap_w - max(0.0, g0))
self.log_event(f"PEAK_GUARD_GAP: the meter missed {gap_s:.0f} s "
f"of this 15-minute period, counted at "
f"{self._gap_w:.0f} W",
hint=messages.hint("peak_gap"))
self._gap_filled_s = max(self._gap_filled_s, gap_s)
if seen is not None:
self._gap_seen_w = seen
if self.grid is not None:
self._gap_pre = (since, float(self.grid))
out, self.peak_gap_s, self.peak_unmeasured_s = peakguard.fill_gaps(
proj, gap_w=self._gap_w if self._gap_w is not None else ceiling,
held_ws=self._gap_held_ws, **kw)
return out
def _peak_over_drain(self, claims, maint_results) -> None:
"""SAFETY-83: at N=1 a peak floor above the drain rate outranks it.
@@ -4218,6 +4280,10 @@ class Controller:
# gives for SAFETY-18 on a transport that cannot see `unchanged_s`.
self._peak_proj = (None if not self.p1_enabled
else self.peak.project(self.p1.averager, now))
_reading = self.peak.peak(now) if self.p1_enabled else None
# SAFETY-90: seconds a meter gap left uncounted are counted, so the
# guard goes on after the readings return.
self._peak_proj = self._fill_peak_gaps(self._peak_proj, now, _reading)
# SAFETY-91: at N>=2 the quarter's edge is graded on the next quarter,
# so a HOLD's ceiling does not lapse for a cycle onto a held battery.
if self._peak_proj is not None and len(self.inverters) > 1:
@@ -4232,7 +4298,7 @@ class Controller:
batt_w=self.site_batt_w,
cap_w=float(self.o.get("peak_cap_w", 3500)),
margin_w=self.peak_margin_w,
reading=self.peak.peak(now),
reading=_reading,
# ⚠️ SUMMED FROM THE PER-UNIT CONJUNCTION, WHICH IS AC 4. Each
# unit contributes `min(its max_w, |its own device bounds|)`, so
# inverter B's rating bounds inverter B. Conjoining the SUMS instead
@@ -6390,6 +6456,11 @@ class Controller:
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_blind(
peakguard.blind_kind(_pg.blind))})
elif self.peak_unmeasured_s > 0.0:
# SAFETY-90: the start of this quarter came before the first
# reading, and the guard counts it at the aim.
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_unmeasured()})
elif _pg.engaged:
out.append({"ok": False, "warn": True, "id": "peak_guard",
"text": messages.row_peak_guard_on(