SAFETY-10: the whole decision path runs and nothing reaches the inverter
checks / unit (pull_request) Successful in 7m58s
checks / unit (pull_request) Successful in 7m58s
Every optimiser defect this project has found was invisible from outside while it was happening, and each was paid for at the meter first: SAFETY-45's 28 charge onsets an hour against a binding peak_cap_w, TARIFF-14's wrong quarter-hour for 45 minutes in every 60, SAFETY-46's 598 Wh spent to gain 310 Wh. There was no way to watch what the optimiser WOULD do without letting it do it. `shadow_mode` runs strategies, arbiter, clamps and guards, records the decision with its reason, and commands nothing. ⚠️ IT WRITES. It writes 0 W, on the ordinary heartbeat, through the ordinary single writer. The inverter holds its last command forever - it has no meter timeout - so "commands nothing" implemented as "stops writing" would leave whatever was standing when shadow mode came on standing for as long as it was left on, under a page saying nothing is being commanded. That is the failure this repository keeps finding. Refreshing 0 W is also what firmware/goodwe-master.yaml's 30 s stale-input watchdog requires of us; going quiet would keep that board tripped for the whole run, which is an alarm being used as a mode. ⚠️ IT IS NOT A SECOND WRITE PATH. No claim, no transport, no arithmetic of its own. It is a substitution inside Controller._write_unit() - the single choke point every write already reaches - in the same form as the three above it, and it is the LAST of them, so SAFETY-28's gate and SAFETY-03's clamp still grade the number the decision path produced. ⚠️ THE DEFAULT IS `auto`, NOT `true`, AND THAT IS THE CARD'S REAL CONTENT. The Supervisor composes options as {**config.yaml defaults, **stored user options}, so a new key with a new default reaches EVERY EXISTING INSTALL on the next update - including the one regulating a real battery. A boolean default-on would have stopped it silently. There is no mechanism by which one key can default differently for a new install and an existing one, so "default-on for new" is a value the add-on RESOLVES: `auto` is shadow while control is STOPPED and live once it is STARTED. A fresh install ships `auto_start: false` and comes up observing; an install that is controlling is started and does not change by one watt. THE FAILSAFES. Sign watchdogs (SAFETY-02/30): INERT - they grade Inverter.standing_w(), which shadow mode holds at 0 W. Fed the shadow decision they would disagree with a meter that never saw it and LATCH A TRIP THAT SURVIVES INTO LIVE OPERATION AND A RESTART. Clamp (SAFETY-03), write gate (SAFETY-28), meter freeze (SAFETY-18), peak guard: OBSERVE. Circulation (SAFETY-31) and delivery (SAFETY-42): observe and may legitimately latch, because their evidence is measured power. The operator stop is the one deliberate change: enforced at the wire rather than as a P_SAFETY claim, which would otherwise make every recorded decision read "stopped". ⚠️ RECORDED LIMITATION: _shadow_settle() re-seeds the carried command to what stands on the wire, which makes the exit safe by construction - and therefore the loop leg's shadow decision is ONE SLEW STEP, not a trajectory. A shadow run answers "what would it command now", not "what would it have done next". The strategies are unaffected; all three defects above are visible from one. Graded on the writes and on the rendered surface, never on the flag: 22 mutations, no survivors, including one that lets a write escape and one that goes silent instead of commanding 0 W. Closed loop on TEST-23 stage 3's rig, same hour twice: live drives the pack to -2000 W and SoC 50.000 -> 62.331 %; shadow commands 0 W throughout, SoC stays 50.0 exactly, and the arbitrage decision is identical in action, instant, signed power, reason and arbiter winner. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
@@ -28,6 +28,42 @@ if it has, it needs 0.10.0. Whoever deploys decides.
|
||||
| _this branch_ | TARIFF-18 - `price_taxes_eur_kwh` stops shipping at half the real Flemish figure **⚠️ CHANGED DEFAULT** |
|
||||
| _this branch_ | TARIFF-16 - the injection leg stops being one number: an injection formula with its own coefficients, its own VAT and no floor under zero |
|
||||
| _this branch_ | SAFETY-45 - a price-driven charge is SIZED by the capacity-tariff guard instead of being switched on and off by it **⚠️ CONTROL STABILITY** |
|
||||
| _this branch_ | SAFETY-10 - shadow mode: the whole decision path runs and nothing reaches the inverter **⚠️ NEW OPTION, DEFAULT-ON FOR A NEW INSTALL** |
|
||||
|
||||
### SAFETY-10 — shadow mode, and what its default does to YOUR install
|
||||
|
||||
A new option, `shadow_mode`, with three values and a shipped default of
|
||||
`auto`. In shadow mode the add-on runs its entire decision path — strategies,
|
||||
arbiter, clamps, guards — and **sends nothing to the inverter**: every inverter
|
||||
is held at **0 W**, refreshed on the ordinary heartbeat by the ordinary single
|
||||
writer, and the status page says plainly that the battery is not being
|
||||
controlled. What it *would* have commanded, and why, is on the status page and
|
||||
in the action log.
|
||||
|
||||
⚠️ **WHAT HAPPENS TO AN EXISTING INSTALL: NOTHING.** `auto` resolves to shadow
|
||||
mode only while control is **stopped**. An install that is controlling —
|
||||
`auto_start: true`, or *Start / stop control* pressed — is started, so `auto`
|
||||
resolves to ordinary control and not one watt changes. An install that is
|
||||
**stopped** keeps its actuator at 0 W exactly as it did before, from the same
|
||||
writer on the same heartbeat; what changes for it is what the status page and
|
||||
the action log **say**, and that the decision path now runs and is recorded.
|
||||
|
||||
⚠️ **AND THAT IS WHY IT IS NOT A BOOLEAN.** The card is titled "default-on".
|
||||
Taken literally — `shadow_mode: true` in `config.yaml` — it would be the worst
|
||||
change in this repository's history: the Supervisor composes an add-on's
|
||||
options as *its defaults, overlaid with the stored user options*, so a new key
|
||||
with a new default reaches **every existing install** on the next update,
|
||||
including the one regulating a real battery at the reference site. It would
|
||||
have silently stopped it, and the only symptom would have been a battery that
|
||||
stopped doing anything. There is no mechanism in the add-on options system that
|
||||
lets one key default differently for a new install and an existing one, so
|
||||
"default-on for new" is expressed as a value the add-on **resolves** rather
|
||||
than a constant the Supervisor merges.
|
||||
|
||||
A **new** install ships `auto_start: false`, so it comes up in shadow mode and
|
||||
observes a day of decisions before it is allowed to command anything. That is
|
||||
the default-on the card asked for, delivered where it is safe and withheld
|
||||
where it is not.
|
||||
|
||||
⚠️ **A CONFIG THAT STARTS ON THE CURRENT VERSION CAN BE REFUSED ON THE NEXT
|
||||
ONE.** TARIFF-07 withdraws `engie_dynamic`, `totalenergies_dynamic` and
|
||||
|
||||
Reference in New Issue
Block a user