EV-20 rig round 2: a short charger read gap keeps the last reading; ha_signed pause timed from the meter age
checks / unit (pull_request) Failing after 43m21s
infra-pin / fresh (pull_request) Failing after 2s

A charger reading missing for less than stale_input_s keeps the last trusted
reading in CarTracker (shared by Solar, Manual and the peak guard): no
decision or write in that cycle, no stuck arm or clear. At stale_input_s the
safe path is unchanged. This also stops the false PEAK_GUARD_FLOOR_LIMITED
after one gap (EV-18 T10(b) updated). On ha_signed Solar's unknown-sun pause
comes at meter age meter_max_age_s + ev_pause_min, checked every cycle.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
Claude
2026-11-23 23:46:48 +01:00
parent 09b6af919b
commit 8d62abe36b
6 changed files with 198 additions and 8 deletions
@@ -144,3 +144,18 @@ one small set of facts and derives every path from them:
`meter_max_age_s` is the bound (a silent meter: 0 A at
`meter_max_age_s` + `ev_pause_min`).
## Rig round 2 (rig FAIL on 09b6af9), PM rulings
- **A short charger read gap** (chargers.py `CarTracker.observe`, shared by
Solar, Manual and the peak guard): a reading missing for less than
`stale_input_s` keeps the last trusted reading (`held`); nothing is decided
or written in that cycle (`ctl_car.car_step` returns), and it neither arms
nor clears the stuck check. At `stale_input_s` the missing reading is taken
as before (the safe path: the charger is gone, 0 A first on its return).
This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap (EV-18
T10(b) changed accordingly).
- **Silent meter on `ha_signed`:** Solar's unknown-sun pause is timed from the
meter's age: unknown since the age passed `meter_max_age_s`, so 0 A when the
age reaches `meter_max_age_s` + `ev_pause_min` (330 s), checked every
control cycle (bound 330 s + one cycle). Arrival sources are unchanged.