diff --git a/goodwe_controller/CHANGELOG.md b/goodwe_controller/CHANGELOG.md index 5457dfd..a0f38b0 100644 --- a/goodwe_controller/CHANGELOG.md +++ b/goodwe_controller/CHANGELOG.md @@ -84,6 +84,18 @@ per-cycle gain the tuning was measured against are unchanged - asserted in `cycle_floor_s` reproduces the old behaviour exactly) and comparing the commanded values. +Observed over six real minutes on the same rig, one binary, meter held at a +literally constant 350.0 W: **before, 1 cycle** (at startup) and then nothing, +the command stuck at 220 W against a 350 W import for the rest of the window. +**After, 24 cycles**, worst gap 15.14 s, and the ordinary PI ramp doing its job - +220, 430, 650, 860, 1080, 1300, 1510, 1730, 1940, 2000 W, one step per cycle, +rail at t=136 s and flat after. Three minutes with the meter parked at the +target instead: **1 cycle before, 12 after, and 19 writes either way - the same +19**. Three minutes on a normally-changing meter: **36 cycles and 49 writes on +both sides, the same values in the same order.** The heartbeat write count never +moves; the only writes the fix adds are the ten the loop was supposed to be +making all along. + 15 s is bracketed, not round. Below it: arrivals are ~5 s (NOTES.md measures 4.97 s), detected up to 1 s late by the 1 s poll, and one dropped poll is retried on the next tick - about 11 s worst case on a meter that is merely