TEL-04: a third meter_source for a single signed entity
TEL-01 shipped ha_dsmr and mqtt_p1, and neither can read the meter that is
actually fitted here. The house has a HomeWizard P1 exposing ONE signed
entity, sensor.p1_meter_active_power (+ import, - export); ha_dsmr wants two
unsigned registers and refuses a negative one outright, which is every
exporting telegram. So sensor.p1_sample_age_s could not be produced at this
site, and FW-01's watchdog needs it - measured, not theoretical: the house P1
went 51.1 s and 36.2 s without a state change overnight, both past
meter_max_age_s 30, so without the age sensor the watchdog would false-trip
the battery to 0 W.
Adds meter_source: ha_signed, reading p1_net_entity (and optionally
p1_phase_net_entities in L1..L3 order for the capacity-tariff peak). The
derivation is split_signed(), sitting next to make_sample's subtraction for
the same reason it does - the moment a user is asked to write two template
sensors that split a signed value, the sign convention is back in unreviewed
YAML underneath a safety input, which is exactly what TEL-01 removed.
The transport is a subclass of HaDsmrSource overriding only _wanted() and
build(), so every rule TEL-01 established is inherited rather than
re-implemented: ingest timestamping, meter_max_age_s, the clock-recomputed
sensor.p1_sample_age_s republished ~1 Hz, the plausibility ceiling, the
"prime the cache from get_states but never build a sample out of it" rule,
"a reconnect emits nothing", and unavailable/unknown treated as a MISSING
reading and never as 0 W.
Defaults to off. An existing install is unaffected until it opts in.
test_p1.py: 122 -> 174 checks. Includes an end-to-end run of the new
transport against a fake Home Assistant websocket, and the sign convention
asserted against real captured readings from
sim/scenarios/ha-p1_meter_active_power-2026-08-{20,23}.json (-5710 W at
13:46 local under full sun is export; +775 W at midnight is import).
Non-vacuity: ten mutations of the new rules, each applied alone and reverted
byte-identical. Nine turn the suite red. The tenth - splitting the per-phase
signed values rather than passing them through - is an equivalent mutant,
because make_sample subtracts the two lists again and does not sign-check
per-phase figures. That is recorded in a ponytail: comment at the site rather
than left for the next reviewer to rediscover.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
This commit is contained in:
co-authored by
Claude Opus 5
parent
c24bc0a011
commit
8b51a51e20
@@ -42,7 +42,9 @@ options:
|
||||
# --- P1 meter ingestion (specs §5.2 / §14 `meter:`) -------------------------
|
||||
# `off` keeps the original single meter_entity path above, so an existing
|
||||
# install is untouched until it opts in. ha_dsmr subscribes to the DSMR
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below.
|
||||
# integration's entities over the HA WebSocket; mqtt_p1 reads the topic below;
|
||||
# ha_signed reads ONE signed HA entity (+ import / - export), which is what a
|
||||
# HomeWizard P1 publishes and what ha_dsmr cannot consume.
|
||||
meter_source: "off"
|
||||
meter_phases: 1
|
||||
meter_max_age_s: 30
|
||||
@@ -55,6 +57,15 @@ options:
|
||||
# three-phase connection; the list length must equal meter_phases.
|
||||
p1_phase_import_entities: []
|
||||
p1_phase_export_entities: []
|
||||
# ha_signed only. ONE signed net-power sensor: positive = import from the
|
||||
# grid, negative = export to it. Do NOT split it into two template sensors -
|
||||
# the split is done in the add-on (p1.split_signed) precisely so the sign
|
||||
# convention is tested rather than living in unreviewed YAML.
|
||||
p1_net_entity: ""
|
||||
# Optional, in L1..L3 order, each one signed the same way. Same role as
|
||||
# p1_phase_import_entities: the capacity-tariff peak on a three-phase
|
||||
# connection. The list length must equal meter_phases.
|
||||
p1_phase_net_entities: []
|
||||
|
||||
# --- control ---------------------------------------------------------------
|
||||
max_w: 2000
|
||||
@@ -98,7 +109,7 @@ schema:
|
||||
batt_invert: bool
|
||||
setpoint_entity: str
|
||||
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1)
|
||||
meter_source: list(off|ha_dsmr|mqtt_p1|ha_signed)
|
||||
# ⚠️ 2 is accepted by this range but is not a real Belgian connection. A
|
||||
# telegram whose phase count disagrees is rejected at ingest and logged, so a
|
||||
# mis-set 2 shows up immediately as "0 telegrams accepted" rather than as a
|
||||
@@ -112,6 +123,9 @@ schema:
|
||||
- str
|
||||
p1_phase_export_entities:
|
||||
- str
|
||||
p1_net_entity: str?
|
||||
p1_phase_net_entities:
|
||||
- str
|
||||
|
||||
max_w: int(100,5000)
|
||||
gain: float(0.05,1.0)
|
||||
|
||||
Reference in New Issue
Block a user