SAFETY-96: a battery the loop cannot move does not freeze it
At N>=2 a battery out of the split (stale link), with refused writes, or settling after a step the loop did not make (a charge end, a rejoin) now counts in the freeze test at its command, not its reading. Its real power still reaches the loop through the meter. At a drop its share leaves the loop's start point (the others take over one slew step a cycle); at a rejoin it enters at its reading. No refusal is learned while a battery's writes are refused. N=1 and the 46 identity digests are byte-identical. test_safety78 part 2: the dropped-drain case now rests at B 1510 W (grid at its -10 W aim) instead of 1500 W; the drop no longer sends B to 2500 W. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
1bf6b7f9a7
commit
88b9cd470a
@@ -1700,6 +1700,8 @@ batteries the other one gives first. The hold still ends on its clock
|
||||
(SAFETY-86).
|
||||
When a charge ends, the other batteries take over one slew step a cycle,
|
||||
and none starts charging from the grid (SAFETY-93).
|
||||
When a battery's link drops, the others take over one slew step a cycle,
|
||||
and control does not stall on the dropped battery's power (SAFETY-96).
|
||||
|
||||