SAFETY-125: a grid charge counts a late meter reading's seconds; the guard row says "over" when it is
A meter reading late near a quarter's end left seconds the projection did not count (SAFETY-99), and charge_headroom_w() read them as room: the cheap run (and price trading, and the N=2 maintenance charge) went back to full power in the quarter's last seconds and the quarter could land over a banked month peak or the cap. peakguard.charge_room_w() counts those seconds at the held reading for the charge only; the guard's floor is unchanged. The guard row said "idle, heading for 5 814 W, under this month's 5 413 W peak". Over the limit at the current rate the row and the month-peak line now say so, and that the grid charge is cut back. Version 0.19.2, CHANGELOG, DECISIONS. test_safety125.py new; the lag pins in test_price_run_fixes.py and test_opt20.py and the AST pin in test_arbitrage.py follow the change (see the pull request). Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
2932f3af39
commit
88ab8a50e3
@@ -0,0 +1,9 @@
|
||||
# SAFETY-125 - a grid charge under the month peak
|
||||
|
||||
**Status: FIXED in 0.19.2 (hotfix from 0.19.1).** Tests: `test_safety125.py`.
|
||||
|
||||
A grid charge is sized by `peakguard.charge_room_w()`, the guard's headroom
|
||||
with the seconds since a late meter reading counted at that reading (the
|
||||
projection leaves them out, SAFETY-99, the bill does not), and the guard's own
|
||||
floor is unchanged. Evidence (repro on 0.19.1, sweep, digests): the SAFETY-125
|
||||
pull request.
|
||||