OPT-09: the weights parameter nothing ever passed, and what it cannot do
checks / unit (pull_request) Successful in 6m8s

`allocator.plan()` has taken a `weights` argument since ALLOC-01 and NOTHING
had ever passed one - main.py called `resolve()` without it and the arbiter
defaulted it to 1.0 per unit - so the site target was split 50/50 regardless
of what either pack could do. Two things now feed it, and they are different
kinds of thing:

  * a `pack` UNIT claim at P_SAFETY that CLOSES a unit's envelope at its own
    `bms_soc_floor` or at 100 % - a PERMISSION, obeyed absolutely, so an empty
    pack is not asked to discharge and its share goes to the sibling;
  * SoC-aware weights by ENERGY headroom in kWh - a PREFERENCE, which
    `_fill()`'s last-resort pass will override the moment the sibling saturates.

Measured (test_packshare.py part 8): at a load one pack cannot cover, the
weighted arm and the shipped arm command the IDENTICAL watts into an empty pack
and deliver the IDENTICAL watts. Only the envelope stops the ask, and what it
buys is not delivery - it is a reported `unmet_w` where the record used to read
impeccable. Weights are a comfort choice for STABILITY and NOT for DELIVERY.

Also: an optional per-entry `capacity_kwh` (schema change, all-or-nothing across
the roster, rule 9 refuses a partial one); per-pack arbitrage sizing, with the
sell side's no-op stated rather than hidden; and a 0 W trade refused by name,
because a 0 W arbitrage claim is a park order that outranks the loop.

SAFETY-42 and this card meet at one hazard from opposite sides - OPT-09 stops
the site ASKING a pack whose SoC says it cannot deliver, SAFETY-42 alarms when a
pack that said it could does not - and its end-to-end fixture moved as a result.
Its finding is unchanged and is now stated on the two quantities its rejected
discriminator actually reads.

Not filed at all at a roster of one: at N=1 every source routes to the site, so
the interval would bound the SITE TARGET, and SAFETY-25's decided Option A
stands untouched on the live install.

⚠️ INVERTER B DOES NOT EXIST. Its 4600 W / 20.48 kWh / 10 % are FROM DATASHEET
AND SERIAL, and `sim/plantsim.py`'s INVERTER_B is inverter A copied
(`measured=False`), so every two-inverter figure here is arithmetic or two
copies of A. No hardware was touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
glenn schrooyen
2026-09-06 20:36:19 +02:00
co-authored by Claude Opus 5
parent 464d398051
commit 83df37963e
20 changed files with 2313 additions and 81 deletions
@@ -0,0 +1,249 @@
# OPT-09 - the weights parameter, and what it is honestly for
**Status:** implemented. **Branch:** `OPT-09`. **Base:** `release/1.0` @ `464d398`.
## 0. What was actually wrong
`allocator.plan()` has taken a `weights` argument since ALLOC-01, `_fill()`
consumes it in two passes, and **nothing had ever passed one**. Confirmed on the
base commit:
arbiter.py:535 def resolve(claims, *, units=None, weights=None, live=None, ...)
main.py:2272 resolve(claims, units=self.units, live=self.live_units(), ...)
So `weights` was None on every tick of every install, `plan()` turned that into
1.0 per unit, and the site target was split **50/50 regardless of what either
pack could do**. The card was filed as "per-pack arbitrage sizing"; the architect
pass found the sharper content, and it is the sharper content that this branch is
mostly about.
## 1. Two instruments, and they are not interchangeable
`allocator.py` states the rule this card is built on, and it is mechanical rather
than advisory:
> WEIGHTS EXPRESS PREFERENCE. ENVELOPES EXPRESS PERMISSION. A weight of 0 is
> "please do not use this unit", and it is honoured while any other unit has
> headroom - but it is NOT a constraint.
`_fill()` runs a deliberate **last-resort pass** over the zero-weight units when
the preferred ones saturate, so that a preference can never manufacture a
standing error at the meter. A pack at its own cut-out that is only *weighted*
to zero is therefore still commanded to discharge the moment its sibling fills
up. So this branch ships both:
| | question | mechanism |
|---|---|---|
| `packshare.envelope()` | MAY this pack be asked, at all, in this direction? | a `pack` UNIT claim at `P_SAFETY`, `hi = 0` at the cut-out, `lo = 0` at 100 % |
| `packshare.weights()` | GIVEN that both may, which should carry more? | energy headroom in kWh, handed to `resolve()` |
## 2. ⚠️ What the weights CANNOT do
ARCH-01's convex-combination argument - the gain at the meter is
`sum(a_i * g_i)`, so it lies in `[min g_i, max g_i]` for **any** split -
guarantees that a bad split cannot **destabilise** the site. It says nothing
about whether the site can **regulate**. A unit at its energy limit has
`g_i = 0`; the combination is still inside the interval and the load it was
asked to carry simply does not move.
Measured, `test_packshare.py` part 8, two units rated 2000 W each, B sitting on
its own floor and therefore answering 0 W to any discharge command. The plant is
modelled in that file (`lag_s = 0`, obeys within one cycle, bounded by its
rating) and the loop is the real `compute()`:
| load | arm | site target | shares | grid | unmet |
|---|---|---|---|---|---|
| 1500 W | shipped | +3000 W | A +1500, B +1500 | 0 W | 0 W |
| 1500 W | weights | +1500 W | A +1500, B +0 | 0 W | 0 W |
| 1500 W | envelope | +1500 W | A +1500, B +0 | 0 W | 0 W |
| 3000 W | shipped | +4000 W | A +2000, B +2000 | +1000 W | 0 W |
| 3000 W | weights | +4000 W | A +2000, B +2000 | +1000 W | 0 W |
| 3000 W | envelope | +4000 W | A +2000, B **+0** | +1000 W | **+2000 W** |
Three things are worth reading off that table, and the second and third are the
uncomfortable ones:
1. At a load the healthy pack can cover, the weights alone deliver the whole
improvement. The shipped arm reaches the same meter reading only by winding
the site target to **twice the load** and standing a +1500 W command on a
battery that answers nothing, permanently saturation-frozen. That is not a
working site, it is a site with no headroom left for the next load step.
2. At a load it cannot cover, **the weights stop working entirely**. The
weighted arm and the shipped arm command the identical +2000 W into the empty
pack, because `_fill()`'s last-resort pass hands the remainder to the
zero-weighted unit. Same shares, same watts, same error.
3. **And the envelope does not rescue the delivery either - it names the
shortfall.** Same 2000 W delivered, same 1000 W standing at the meter. What
changes is that the empty pack is commanded 0 W instead of 2000 W, and 2000 W
of site target is *reported* as unplaceable instead of appearing to have been
placed.
> **Weights are a comfort choice for STABILITY and NOT for DELIVERY.** Nothing in
> this add-on shifts a unit's load to its sibling once the sibling is at its
> rating, and weighting a failing unit down is not a remedy for it.
## 2b. ⚠️ The card's own premise is only half true
The card opens with *"a unit that stops delivering its share (empty, full,
curtailed, wedged) parks the site with a standing grid error and no alarm."*
After this branch: the **ask** stops, and while the sibling has headroom the site
regulates to zero error instead of winding to twice the load. The **standing grid
error does not stop** once the sibling is at its rating - §2's table measures
1000 W standing in all three arms - and there is **still no alarm** for it, only
a report. SAFETY-42 will not alarm on a pack at its own floor; that is one of its
acceptance criteria and its evidence is that the benign and the wedged case are
indistinguishable in the power domain.
So the two cards together mean: an empty pack limiting the site is now REPORTED
(`unmet_w`, an action-log line) and still, deliberately, NOT ALARMED. Whether it
should be alarmed is a decision - and the alarm it would need is about a site's
stored ENERGY, not about an inverter's delivery, so it is not this card's and not
SAFETY-42's. Recorded rather than quietly closed against a premise this card only
half meets.
## 3. Which floor, and which ceiling - the two places this could have become policy
**The floor is `bms_soc_floor` alone, never `peakguard.pack_floor_pct()`.** That
function's conjunction with `peak_soc_floor` is right for the peak guard and
wrong here: SAFETY-25 decided (2026-09-02, Option A) that `peak_soc_floor` bounds
the peak guard **only**, ordinary self-consumption discharges straight past it,
and closing an envelope at it would turn an operator preference into a hard stop
on the grid-following loop - the memo's **deferred Option B**, built by accident.
`delivery.py`'s `account()` made the same choice one step out, for the same
reason. Graded: a pack at 15 % with a 10 % cut-out is not closed, though a 20 %
EMS floor would have closed it.
**The ceiling is 100 %, and the coarseness is the honest answer.** There is no
per-pack charge ceiling anywhere in this add-on - `delivery.py` says so at length
and calls it a card, and it is why SAFETY-42 is armed on discharge shares only.
The only other number available is `arbitrage_soc_ceiling`, which is one
site-wide **trade policy**; filing it as a `P_SAFETY` envelope on the loop would
be the mistake above in the charge direction. So the envelope closes only where
the ask is physically impossible, and everything between is left to the weights -
which is the right instrument for a graded preference and is honest about being
only a preference.
## 4. N=1, and the tripwire this had to argue past
`actuator_for()` routes **every** source to the site at one inverter, so a `pack`
interval filed there would bound the SITE TARGET rather than a share. `main.py`
therefore does not file it at all below a roster of two - the same guard, for the
same reason, that SAFETY-30's `sign_site` carries. AC 4 ("at N=1 allocation is
byte-identical") is that `if`.
`test_peakguard.py` part 10f pins the claim-source set against `main.py`'s own
AST precisely so that a state-of-charge-conditioned claim cannot arrive quietly.
`pack` is state-of-charge-conditioned, so the argument is written at that set
rather than the count edited: the number is not an option, the claim is
unit-scoped so it cannot bound the site target, it is not filed at N=1, and part
10f's own note names this as the revisit trigger - *"under ALLOC-01 the reserve
becomes a PER-INVERTER INTERVAL AT THE ALLOCATOR rather than a ninth claim
here"*. Stage 1 is how an interval reaches the allocator and stage 1's input is
claims, so a unit-scoped claim is the shape that sentence asks for.
**What N=1 still does not get, said plainly:** nothing stops the loop discharging
into the BMS cut-out at one inverter. That is unchanged, it is SAFETY-25's
deferred option, and the BMS is what stops it.
## 5. SAFETY-42 - the same hazard from the opposite side
They meet and do not overlap, and the seam is **the state of charge**:
* **OPT-09 stops the site ASKING** a pack whose own SoC says it cannot deliver.
* **SAFETY-42 alarms** when a pack that said it could does not.
A wedged unit reads a healthy SoC, so no envelope closes and no weight moves -
OPT-09 cannot see it at all. A pack at its floor is `account()`'s explained case,
so SAFETY-42 stays silent - and after this card that ask does not arrive in the
first place, which removes the benign arm from the detector's input rather than
teaching it a new discriminator.
⚠️ **And OPT-09 supplies the mechanism SAFETY-42 said was missing, without
connecting it.** That module's rejection of re-allocation rests on *"the only
re-allocation this add-on can express is ALL OR NOTHING [...] a partial
re-allocation is what would make acting safe, and the allocator has no way to
express it today"*. Passing weights **is** that expression. Wiring delinquency
into them is deliberately **not** done here: it would be acting on the alarm,
which SAFETY-42 refused with rig evidence (a unit derated to 50 % is 400 W worse
dropped than kept, and no instrument this add-on has can tell it from a wedged
one), and - see §2 - a weight cannot stop a unit being commanded anyway. That is
a card, and this paragraph is its input.
## 6. Per-pack arbitrage sizing, and the half that is deliberately not moved
`arbitrage.decide()` was handed `site_max_w` on **both** sides, so a two-pack
site would buy at the sum of the ratings whatever either pack's state of charge
was. It is now sized to the packs whose own SoC permits that direction
(`Controller.trade_power_w()`), using **arbitrage's own** bounds rather than the
BMS cut-out - sizing a trade is the trade's business; permitting a command is the
pack's.
Two honest limits:
* **The sell side is a no-op on every roster today.** `decide()` is handed
`pack_floor_soc` - the emptiest pack - so a sell is refused outright whenever
*any* pack is at or under the floor, i.e. in exactly the states where the sum
could be smaller than the site rating. The arithmetic is graded directly
(`test_packshare.py` part 9); it becomes reachable the day that gate is
per-pack.
* **Moving that gate is not this card's.** Sizing a sell off the *fullest* pack
would let the trade proceed while the emptiest pack was below
`arbitrage_soc_floor`, and the only per-pack instrument that could keep it out
of that pack is the weights - which are a preference, and `_fill()` will hand
it watts anyway. Doing it safely needs an envelope that depends on WHICH CLAIM
WON the tick, which the arbiter's partition does not express. §2 is why that is
a real objection and not a hedge.
`arbitrage.decide()` also now refuses a **0 W sizing** by name (`IDLE_NO_SIZE`),
because a `Claim.set(..., 0.0)` at `P_ARBITRAGE` is a park order that outranks
the loop - the failure the note on `claim()` is already written against. The
sizing can never be zero on a tick that trades today; that is a coincidence of
the existing gate, and this makes it structural instead.
## 7. The fixture, which is the hard part
Two packs that differ in only ONE of SoC and capacity cannot separate a
SoC-aware weighting from a capacity-aware one; two identical packs cannot
separate ANY weighting from any other. `test_packshare.py` part 1 grades the
fixture itself before anything is asserted with it - four candidate schemes
(equal, power rating, SoC only, energy), four distinct splits of the same
1000 W:
equal A +500, B +500
power A +521, B +479
soc only A +125, B +875
energy A +97, B +903
and the counterfactuals: on two identical packs all four collapse to one answer;
at the same SoC, `soc only` collapses onto `equal`; at the same capacity,
`energy` collapses onto `soc only`.
## 8. Provenance of every number
* A: **5000 W, 15.36 kWh, 10 % floor** - measured (GW5000S-BP, register 0x0560).
* B: **4600 W, 20.48 kWh, 10 % floor** - **FROM DATASHEET AND SERIAL**
(`goodwe/NOTES.md` §1.1b, GW5048D-ES `55048ESU22AW0992`). ⚠️ **Inverter B does
not exist** (expected ~2026-09-12).
* Every two-unit run in `test_packshare.py` is arithmetic over intervals and
weights, or a plant modelled in that file. `sim/plantsim.py:216`'s `INVERTER_B`
is **inverter A copied** with `measured=False`, so any two-inverter simulation
result anywhere in this project is **two copies of A**.
* No rig was taken, no hardware was touched, and nothing here is evidence about
a second GoodWe inverter.
## 9. Config
`capacity_kwh` joins the `inverters` roster as an **optional** per-entry key
(`float(0.1,200)?`) - the opposite choice to SAFETY-32's required
`bms_soc_floor`, and for that card's own reason: a missing cut-out would have to
be *defaulted*, and one default for two batteries protects the shallower pack
with the deeper pack's number, whereas a missing capacity has an honest answer -
no opinion about the split, every unit weighs 1.0, which is exactly what shipped.
It is **all or nothing across the roster** and rule 9 refuses a partial one: a
pack measured in kWh beside a sibling weighing a dimensionless 1.0 is not a
comparison, `weights()` answers "no opinion" for the whole roster in that case,
and a key that silently changes nothing is worse than one that refuses to load.
There is deliberately **no flat `capacity_kwh`**: at one inverter there is no
split to weight, so it would be an option an operator can set and nothing reads.