SAFETY-97: point test_safety97 at MUTATION.md; record the DC-entity option
checks / unit (pull_request) Successful in 29m9s
infra-pin / fresh (pull_request) Failing after 1s

test_bytecode requires every suite to name MUTATION.md (CI run 1158).
DECISIONS: why the integration's DC battery power entity is not the fix.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
2026-10-04 12:51:52 +02:00
co-authored by Claude Opus 5.5
parent 6918e154c8
commit 80bfc5721e
2 changed files with 20 additions and 1 deletions
@@ -34,6 +34,25 @@ B sat on the band's edge and never latched:
start is never quiet, so never learned, so never caught.
- **Until learned the idle reading is 0 W**: the rule as it was.
## Not chosen: the GoodWe LAN integration's DC battery power
Both inverters also appear through HA's GoodWe integration (B:
`sensor.kelder_dyness_battery_power`, 0 W at idle; found read-only on the
live HA 2026-10-04). Pointing `batt_entity` at it removes B's offset by
configuration, but:
- the band must be safe without it: other installs may not have it;
- it is polled over UDP on the inverter's Wi-Fi, a second channel that can
drop while the board keeps reading (HW-01 lost both once); a missing
reading stops the site;
- SAFETY-37's 35 s bound is derived from the board's 10 s publish; the
integration's poll interval (believed 10 s, not checked here) and latency
are not measured;
- DC power is not 0x0518, which SAFETY-30/31/42 were measured against.
It stays an install choice to test on the rig, not a code change here. With
it, the learned idle reading is simply ~0 W.
## Where it applies
Every test of "gives nothing / gives / takes" now uses `reading - idle`: