SAFETY-85 review: grade discharge only, over the plant's settle time
Rule 2 graded each battery against last cycle's command and graded charges too. On plantsim's battery (10 s lag) at the 2 s meter it warned at every drain or charge start and 15 times an hour under the peak guard at N=2; a charge tapering near full warned 11 times in 50 min (SAFETY-42 section 7). Now a discharge is graded against the least it stood at over SHORT_CYCLES / SHORT_SPAN_S. DOCS lists `mode-bound` under Loop reason. test_safety85 part 7: peak guard with a dead battery, lagging plant, taper; part 3: the bound ends with maintenance. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -25,14 +25,16 @@ counter counted cycles (861), not episodes.
|
||||
the loop. Its number is on the wire, or only a rating (`device`,
|
||||
`supervised`) cut it. No bound held it, and nothing was unmet.
|
||||
(`Controller._loop_alarm_input`.)
|
||||
2. **A battery another owner set alarms when it gives less than it was told.**
|
||||
This covers every battery on a cycle the loop did not decide, and a battery
|
||||
with its own pin otherwise. The test is more than `saturation_w` short in
|
||||
the told direction, for `saturation_cycles` cycles in a row, against what
|
||||
stands on the wire (`clamp.delivery_short`). It covers a real shortfall
|
||||
during maintenance. Before, that shortfall was silent unless the kick
|
||||
happened to reach the rail (house 1000 W, drain 2000 W, battery gives
|
||||
nothing: 0 warnings before, 4 in 10 min now).
|
||||
2. **A battery another owner set to discharge alarms when it gives less than
|
||||
it was told.** This covers every battery on a cycle the loop did not
|
||||
decide, and a battery with its own pin otherwise. The test is more than
|
||||
`saturation_w` short of the least it stood at over `SHORT_CYCLES` cycles
|
||||
and `SHORT_SPAN_S` (the plant's measured settle, SAFETY-13/73), for
|
||||
`saturation_cycles` cycles in a row (`clamp.delivery_short`). It covers a
|
||||
real shortfall during maintenance or under the peak guard. Before, that
|
||||
shortfall was silent unless the kick happened to reach the rail (house
|
||||
1000 W, drain 2000 W, battery gives nothing: 0 warnings before, 4 in 10 min
|
||||
now).
|
||||
3. **At N>=2, while maintenance holds a battery, the loop is bounded** by
|
||||
OPT-11's `loop_bound()` (what the batteries may place). It does not wind,
|
||||
and control comes back one slew step a cycle. Why maintenance only: that is
|
||||
@@ -69,12 +71,21 @@ batteries can give. The `alarmed()` helpers in test_safety84/86 also read
|
||||
SAFETY-81's quarter stamp, because ALLOCATOR rows can push its row out of
|
||||
the 40-row log.
|
||||
|
||||
**Review (PR #163).** The first draft graded each battery against last
|
||||
cycle's command and graded charges too. On plantsim's battery (10 s lag) at
|
||||
the live 2 s meter, every drain or charge start warned once, and an N=2 drain
|
||||
or HOLD under the peak guard with a stepping house warned 15 times an hour. A
|
||||
maintenance charge tapering near full warned 11 times in 50 min, which
|
||||
SAFETY-42 section 7 had ruled out. With the settle window and discharge only:
|
||||
0 in all of those cases. A battery that gives nothing still warns, lagging
|
||||
or not. At a hypothetical 20 s lag, it warns at most twice an hour. The cost:
|
||||
a battery that does not take a charge another owner set is not named by this
|
||||
alarm (the same gap SAFETY-42 states; the charge has its 36 h timeout).
|
||||
`test_safety85.py` part 7.
|
||||
|
||||
**Not changed, open for the owner.**
|
||||
- With the loop in charge and the house above the batteries' total rating,
|
||||
it still warns (SAFETY-40). On the rig's 2 x 2000 W N=2, most of SAFETY-84's
|
||||
count came from houses of 4500 and 6500 W.
|
||||
- A battery that tapers near full during a charge, more than `saturation_w`
|
||||
under its command for 15 s, now warns (rule 2). The text already says
|
||||
"check it is not empty or full".
|
||||
- TEL-10's `loop_reason` reads `mode-bound` while the maintenance bound holds
|
||||
the loop, with modes off.
|
||||
- TEL-10's `Loop reason` reads `mode-bound` while the maintenance bound holds
|
||||
the loop, with modes off. DOCS lists the value with both meanings.
|
||||
|
||||