UX-08 review: tighter notification texts, and two meaning fixes
- not delivering: the body said control keeps running and then "start
control"; clearing it takes stop then start, and it now says so.
- peak reserve: the "reserve not set" branch is really soc_floor None,
i.e. an inverter's cut-out level missing; it now names that. The title
is true on all three branches ("Battery stopped limiting the peak").
- no semicolon run-ons in bodies (STYLE.md + test); loop-bound, circulating,
meter-frozen and multi-unit over-rating bodies rewritten to match.
- allowlist cap is now exact, so a shrink cannot leave room to regrow.
- DOCS names the settings behind "peak reserve" and "cut-out level";
DECISIONS no longer states the HA anchor behaviour as fact.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -2816,7 +2816,7 @@ texts live in `app/messages.py`. Every notification keeps a fixed
|
||||
| Battery is not keeping up | warning | `goodwe_integrator_bound` |
|
||||
| Power request too high | alarm | `goodwe_output_clamp` |
|
||||
| Load too high for battery | alarm | `goodwe_peak_saturated` |
|
||||
| Battery at its peak reserve | alarm | `goodwe_peak_soc_floor` |
|
||||
| Battery stopped limiting the peak | alarm | `goodwe_peak_soc_floor` |
|
||||
| Inverters working against each other | alarm | `goodwe_circulating_power` |
|
||||
| *name* is not delivering | alarm | `goodwe_not_delivering_<name>` |
|
||||
| Meter reading may be stuck | alarm | `goodwe_meter_frozen` |
|
||||
@@ -2854,11 +2854,17 @@ than the inverter. Switching off load in the next few minutes is the only thing
|
||||
that still changes the bill. The projection and the watts are in the add-on log
|
||||
and on the status page. See *The capacity-peak guard*.
|
||||
|
||||
### Battery at its peak reserve
|
||||
### Battery stopped limiting the peak
|
||||
|
||||
Two words in this notification are settings. The **peak reserve** is
|
||||
*Peak guard will not discharge below (%)* (`peak_soc_floor`). The
|
||||
**cut-out level** is *Battery cut-out level (%)* (`bms_soc_floor`), where the
|
||||
battery's own system stops discharging.
|
||||
|
||||
The peak guard wanted to discharge to hold the 15-minute peak, but it may not go
|
||||
below the peak reserve (`peak_soc_floor`, SAFETY-24). It also stops when the
|
||||
battery level cannot be read, or when no reserve is set. So this 15-minute
|
||||
battery level cannot be read, or when an inverter's cut-out level is not set,
|
||||
because the reserve is graded against it. So this 15-minute
|
||||
period will go over the peak limit and set or raise the month's billed peak.
|
||||
Charging from the grid stays blocked meanwhile. On a site with several inverters
|
||||
the notification names the battery at its limit (SAFETY-32): each battery is
|
||||
@@ -2901,8 +2907,9 @@ to the missing unit's rating. Check, in this order:
|
||||
(`bms_soc_floor`) says? If so, that setting does not describe this battery.
|
||||
3. Is anything else writing to it?
|
||||
|
||||
The alarm is latched and survives restarts; start control on the add-on page
|
||||
once you know why. See *A unit that stops DELIVERING is a third fault again*.
|
||||
The alarm is latched and survives restarts. Control is still running, so to
|
||||
clear it, press *Start / stop control* twice (stop, then start) once you know
|
||||
why. See *A unit that stops DELIVERING is a third fault again*.
|
||||
|
||||
### Meter reading may be stuck
|
||||
|
||||
|
||||
Reference in New Issue