MAINT-28 fix-forward round 2: while the pause holds, the maintenance pack gives only what the peak guard claims
Owner go 2026-11-13. The pack in maintenance CHARGE gets a unit limit with hi = the guard's own floor while the pause holds, at any SoC (replaces the under-reserve limit). Sim 45 min: A give 2.39 -> 0.02 kWh, SoC 49.0 %, charge back 4 s. test_safety84 n2_charge_banked re-pinned (192 of 480 rows), test_maint28 quarter bound to the month peak. Tests: test_maint28b.py. Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
34b81e8aeb
commit
776b84ca20
@@ -40,6 +40,6 @@ The sim had no battery-reading lag, and the first version said the 300 W line is
|
||||
|
||||
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 13 s after the load (7 s in the test), not 0: the first settled estimate. No cut-back is touched.
|
||||
|
||||
**F-2: under its peak reserve the pack gives nothing for the house.** While the pause holds (N>=2, month aim above the cap), a pack in maintenance CHARGE that `peakguard.reserve_split()` holds gets `hi` = 0 W (P_MAINT_SHAPE). The guard's own claim for the peak is on the other packs (`place_on_able()`), so it is unchanged. Above the reserve nothing changes. Sim, B charging at 18 %: f3f9483 gave 1.89 kWh and went to 10.0 % (the log said "giving nothing for the peak"); now 0.00 kWh, 18.2 %, 0 give/idle flips in 45 min (the full cap measured by the reviewer: 32 in 40 min), quarters 5948 and 5952 W (aim 5950).
|
||||
**F-2 and the cap (owner 2026-11-13): while the pause holds, the maintenance pack gives only what the guard claims.** While the pause holds (N>=2, month aim above the cap), the pack in maintenance CHARGE gets a unit limit `hi` = the guard's own floor (0 W when it claims nothing), at any SoC, so it also gives nothing for the house under its peak reserve. `hi` = 0 W alone was tried and is wrong: it crosses the guard's claim and resolves to 0 W (house 12 kW, B under its reserve: quarter 6713 W, a new month peak); with the guard's floor as `hi` the guard still gets its power. Other packs are unchanged (B not in maintenance still gives for the house). Sim, 45 min, house 6500 W: A at 49 %: A gives 0.02 kWh (uncapped 2.39), SoC stays at 49.0 %, charge/give flips 1, quarters 1958 1873 2873 W (all under the aim), charge back 4 s after the load. B at 18.2 % in CHARGE: f3f9483 gave 1.89 kWh to 10.0 % (log "giving nothing for the peak"); now 0.00 kWh, 18.2 %. Give/idle switches of the pack: 15 in 45 min, but they are the guard's claim on and off (3 episodes, one per quarter start, of 94 s at most 490 W, and 5 blips of 5-19 s at 100-490 W, 0.04 kWh in all); bridging gaps under 10 s would make it 3 episodes, 6 switches. Not added.
|
||||
|
||||
Mutants, each red in `test_maint28b.py`: the freshness check dropped (always settled); the reserve claim dropped.
|
||||
Mutants, each red in `test_maint28b.py`: the freshness check dropped (always settled); the cap dropped.
|
||||
|
||||