EV-20 rig round 1: stuck check armed on the reading before the send; no amp ping-pong; ha_signed meter age
infra-pin / fresh (pull_request) Successful in 4s
checks / unit (pull_request) Failing after 1h11m9s

The stuck check's baseline is the signature of the latest reading taken
before the send (kept at begin_write), never one that arrived while the write
waited; a refused write's first post-send sample is its baseline (EV-36).
After a step down, a step back up needs UP_HYST_W past the boundary. Solar's
15 s meter-age gate applies only where the age measures arrival; on
ha_signed it is the source's meter_max_age_s. Rows in test_ev20_rig.py;
harness modes for the rig's interleave and an on-change meter.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
Claude
2026-11-23 14:28:21 +01:00
parent cc8c0dc2ae
commit 711c5f3627
6 changed files with 342 additions and 13 deletions
+24 -3
View File
@@ -141,13 +141,18 @@ def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
margin=100, opts=None, plug=True, setpoint=0, phases=1, mode="solar",
first="batteries", events=None, sim=None, store=None, race=False,
on_cycle=None, car_phases=3, t0=0.0, caps=None, finale=None,
rows=False, plant_cls=None):
rows=False, plant_cls=None, beside=False, meter_change=False):
"""Run it. Returns a dict: plant, controller, charger, notifications with
their second, and a per-second trace. `caps` ({unit: kWh}) lets each
battery's level move with what it charges or gives; without it the
levels stand still. `finale(plant, c)` (a coroutine) runs after the last
cycle, on the model clock (a shutdown, for instance); `rows=True` keeps
the ids of the amber and red rows of every cycle in the trace."""
the ids of the amber and red rows of every cycle in the trace.
`beside=True` plays the production interleave the rig showed (EV-20 rig
round 1): a write that waits for its read-back is still waiting when the
next cycle reads the charger; it resumes after that read.
`meter_change=True` publishes the meter as Home Assistant does on
`ha_signed`: only when the whole-watt value changes."""
ratings = ratings or {"a": 5000.0, "b": 4600.0}
socs = socs or {u: 50.0 for u in ratings}
sim = sim or SimCharger(setpoint_a=setpoint)
@@ -205,6 +210,19 @@ def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
plant.t = clock[0]
c.charger._sleep = sleep
c.charger._clock = lambda: clock[0]
if beside:
gate = asyncio.Event()
async def bsleep(_s):
gate.clear()
await gate.wait()
async def settle():
gate.set()
for _ in range(8):
await asyncio.sleep(0)
c.charger._sleep = bsleep
c.car_settle = settle
real_dt = main_files.live.datetime
class _DT(real_dt):
@@ -224,7 +242,10 @@ def drive(house, sun, *, dur=600.0, ratings=None, socs=None, cap=3500.0,
await r
sim.tick(1.0)
ts = t - SAMPLE_LEAD_S
if plant.meter_on and not plant.ha_down:
if plant.meter_on and not plant.ha_down and not (
meter_change
and round(plant.grid(ts)) == round(plant.meter)
and t > t0):
plant.meter = plant.grid(ts)
imp, exp = split_signed(plant.meter)
c.p1.submit(make_sample(