UX-08 2d: plain log lines, the rest of the status page, and DOCS
checks / unit (pull_request) Successful in 8m55s
infra-pin / fresh (pull_request) Successful in 1s

Every WARNING and ERROR line is one plain line of at most 25 words, with
no card ids, capitals or semicolons; the reasoning of the ten longest is
on a DEBUG line. The ux08 allowlist is empty and its cap is 0 (43 -> 0).

The status page: the month-peak and peak-guard rows, the stale-reading
row, the top table (Why, Tariff, Arbitrage, Shadow mode, labels), the
Stopped banner and the line under the buttons, which now shows the plain
hint of each event instead of the raw action log. The Supervisor question
at start logs one line with a real reason.

Refusals are counted as shown (labels expanded, long cases driven), seven
were shortened, the card and parse errors lost their internals, a blank
value reads "empty", and the panel no longer files inverters.max_w under
the flat max_w. Option names lose "(JSON)", the NL texts are checked too.

DOCS gets a glossary (control board, isolator, Developer Tools) and card
ids move from headings to a "For installers" line.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01LyR88rXETvwhTgx6yHE39p
This commit is contained in:
2026-09-27 08:01:16 +02:00
co-authored by Claude Opus 5.5
parent a02cd4b713
commit 6a95447248
38 changed files with 1294 additions and 742 deletions
+4 -4
View File
@@ -189,13 +189,13 @@ check(f"the wind-down ran: 0 W written AFTER the fault (writes after = {after})"
check("the web runner was cleaned up, i.e. the ordinary shutdown path ran",
["cleanup"] in ev[(fault_at or 0):])
died_line = next((i for i, ln in enumerate(err.splitlines())
if "CONTROL LOOP DIED (RuntimeError('" + FAULT + "'))" in ln), None)
if "Control stopped unexpectedly (RuntimeError('" + FAULT + "'))" in ln), None)
wind_line = next((i for i, ln in enumerate(err.splitlines())
if "shutting down - commanding 0 W" in ln), None)
check("a CRITICAL line names the exception and the exit status",
died_line is not None
and "CRITICAL" in err.splitlines()[died_line]
and "commanding 0 W and exiting with status 70" in err.splitlines()[died_line])
and "set to 0 W and the add-on exits with code 70" in err.splitlines()[died_line])
check("the traceback is logged, down to the frame that raised",
"Traceback (most recent call last)" in err
and f"RuntimeError: {FAULT}" in err and "in cycle" in err)
@@ -211,7 +211,7 @@ print("2. the same entry point stopped by SIGTERM - the callback must stay quiet
rc2, out2, err2, ev2 = run_child("clean")
print(f" exit status {rc2}; events {ev2}")
check("an ordinary stop still exits 0", rc2 == 0)
check("an ordinary stop logs no CONTROL LOOP DIED", "CONTROL LOOP DIED" not in err2)
check("an ordinary stop logs no unexpected stop", "Control stopped unexpectedly" not in err2)
check("an ordinary stop still winds down to 0 W, from a non-zero command",
any(e[0] == "w" and e[1] != 0.0 for e in ev2)
and [e for e in ev2 if e[0] == "w"][-1:] == [["w", 0.0]])
@@ -222,7 +222,7 @@ rc3, out3, err3, ev3 = run_child("refuse")
print(f" exit status {rc3}")
check("a late-arriving device rating refusal exits 78 (EX_CONFIG), not 70",
rc3 == 78)
check("and is not reported as a death", "CONTROL LOOP DIED" not in err3)
check("and is not reported as a death", "Control stopped unexpectedly" not in err3)
if rc3 != 78:
print(tail(err3))