EV-05 round 5: headroom counts only the batteries that can give
Review of 8818768: the headroom test compared the output with the site
rating, which still counted a battery refusing to give (SAFETY-73) or under
a safety stop, so the 15 s wait ran at the real maximum (N4). Now only the
units that can give (above their cut-out, not refusing, not stopped,
switched on) count, in what they give and in their ratings.
Tests: R5a (A refuses, B at full rating, against a car-Off twin: the cut at
910, period 3361 W), R5b (headroom and a slow battery: the cut at exactly
15 s), R5c (floor-limited alone decides: cut at once). DOCS wrapped to 79.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
+30
-30
@@ -3327,14 +3327,14 @@ checks within 10 seconds that the charger took it.
|
||||
current again only if the charger shows a different one.
|
||||
- Off writes nothing, ever.
|
||||
|
||||
**Solar mode.** Choose *Solar* on Home (or `Solar` on `select.goodwe_car_mode`)
|
||||
and where spare sun goes first: **Batteries** or **Car** (`select.goodwe_car_sun_first`).
|
||||
Both apply at once, with no restart.
|
||||
**Solar mode.** Choose *Solar* on Home (or `Solar` on
|
||||
`select.goodwe_car_mode`) and where spare sun goes first: **Batteries** or
|
||||
**Car** (`select.goodwe_car_sun_first`). Both apply at once, with no restart.
|
||||
|
||||
- *Spare sun* is solar production less the house, measured without a solar
|
||||
sensor: the car's power, plus what the batteries charge, less what the grid
|
||||
gives. A grid charge of the batteries, or batteries giving more than the house
|
||||
uses, is never spare sun.
|
||||
gives. A grid charge of the batteries, or batteries giving more than the
|
||||
house uses, is never spare sun.
|
||||
- *Batteries first*: the car gets what is left after the full rating of every
|
||||
battery that may still charge (switched on, not refusing, not full), less
|
||||
*Sun kept back*. So the car gets sun only when the batteries charge at full
|
||||
@@ -3354,18 +3354,18 @@ Both apply at once, with no restart.
|
||||
taken off the car first, down to 0 A if needed. While the batteries can
|
||||
still raise their output, the add-on first waits 15 seconds, so a cloud
|
||||
the batteries catch does not pause the car. It cuts at once when they
|
||||
cannot: already at full power, at the peak reserve or at their cut-out
|
||||
level. It also cuts at once in the last 2 minutes of the 15-minute period. A Solar
|
||||
charge never sets the month's peak.
|
||||
cannot: already at full power, at the peak reserve, at their cut-out
|
||||
level or refusing to give. It also cuts at once in the last 2 minutes of
|
||||
the 15-minute period. A Solar charge never sets the month's peak.
|
||||
- **Every way out of Solar leaves the charger at 0 A**: a stop or
|
||||
restart of the add-on (before the inverters go to 0 W), stopping control, a
|
||||
safety stop, shadow mode turned on, choosing Off, an unplugged car, a charger
|
||||
error or a stuck reading. If the charger does not take the 0 A, the add-on
|
||||
tries again a minute later, three times, then shows *Charger did not take
|
||||
it* and a warning. Once taken, nothing more is written. After the charger
|
||||
or Home Assistant was away, the
|
||||
add-on first sets 0 A, then starts again by the rules. A meter that stops
|
||||
gives a hold for *Pause after*, then 0 A. Choosing Manual leaves it to Manual.
|
||||
or Home Assistant was away, the add-on first sets 0 A, then starts again
|
||||
by the rules. A meter that stops gives a hold for *Pause after*, then 0 A.
|
||||
Choosing Manual leaves it to Manual.
|
||||
- Another writer stops the add-on's writes after 30 seconds, with an amber row
|
||||
and a warning, until you press the mode again or the charger shows the
|
||||
add-on's value again.
|
||||
@@ -3373,24 +3373,23 @@ Both apply at once, with no restart.
|
||||
`sensor.goodwe_car_today_solar_kwh`. Only the sun the car could take counts,
|
||||
not the battery or grid share of a hold, and not Manual.
|
||||
|
||||
**The car is never slowed for the peak limit in Manual.** A Manual charge goes on whatever
|
||||
the 15-minute peak does. With the default `ev_batt_cover` on, the batteries help
|
||||
cover it down to the peak reserve; a 3-phase 16 A charge (11 kW) can empty two
|
||||
batteries to the reserve in about 1.5 hours, and the month's peak then rises by
|
||||
what the car drew. When the car alone is why the batteries cannot hold the
|
||||
period, the add-on does **not** raise *Battery stopped limiting the peak* or
|
||||
*Load too high for battery*. It shows a grey note *Car over the peak
|
||||
**The car is never slowed for the peak limit in Manual.** A Manual charge goes
|
||||
on whatever the 15-minute peak does. With the default `ev_batt_cover` on, the
|
||||
batteries help cover it down to the peak reserve; a 3-phase 16 A charge (11 kW)
|
||||
can empty two batteries to the reserve in about 1.5 hours, and the month's peak
|
||||
then rises by what the car drew. When the car alone is why the batteries cannot
|
||||
hold the period, the add-on does **not** raise *Battery stopped limiting the
|
||||
peak* or *Load too high for battery*. It shows a grey note *Car over the peak
|
||||
limit* once per charging session, a grey row, and says so in the car's *Why*.
|
||||
This holds only while the car's reading is fresh and the charger's energy
|
||||
meter confirms it (the meter must have gained at least half of what the power
|
||||
adds up to over the last minute). A stale, stuck or frozen reading, or a
|
||||
charger with no energy entity, never hides a real overload of the house: the
|
||||
normal alarms stand. With `ev_batt_cover` off, the peak
|
||||
guard protects the house without the car, so it does not spend the batteries on
|
||||
it. Normal zero-grid control can still discharge them for the car, and a grid
|
||||
charge of the batteries can bring the period to the peak limit plus the car.
|
||||
The period can go over by the car alone. When the month's peak was set by a car
|
||||
charge, Home's peak line says so.
|
||||
This holds only while the car's reading is fresh and the charger's energy meter
|
||||
confirms it (the meter must have gained at least half of what the power adds up
|
||||
to over the last minute). A stale, stuck or frozen reading, or a charger with
|
||||
no energy entity, never hides a real overload of the house: the normal alarms
|
||||
stand. With `ev_batt_cover` off, the peak guard protects the house without the
|
||||
car, so it does not spend the batteries on it. Normal zero-grid control can
|
||||
still discharge them for the car, and a grid charge of the batteries can bring
|
||||
the period to the peak limit plus the car. The period can go over by the car
|
||||
alone. When the month's peak was set by a car charge, Home's peak line says so.
|
||||
|
||||
**When the charger does not answer.** After 30 seconds the card says *Charger
|
||||
not reachable* and one amber row appears. After 5 minutes one notification
|
||||
@@ -3432,8 +3431,9 @@ automation on.
|
||||
|
||||
**Home Assistant entities.** With MQTT the add-on adds the sensors
|
||||
`goodwe_car_power`, `goodwe_car_state`, `goodwe_car_today_kwh` and
|
||||
`goodwe_car_today_solar_kwh`, and the four controls named above. A saved ("retained") command is never applied, so a
|
||||
restart of Home Assistant cannot change the charger.
|
||||
`goodwe_car_today_solar_kwh`, and the four controls named above. A saved
|
||||
("retained") command is never applied, so a restart of Home Assistant cannot
|
||||
change the charger.
|
||||
|
||||
### Site
|
||||
|
||||
|
||||
Reference in New Issue
Block a user