MAINT-13 round 3: provider site, hourly fixed-tariff check, faster tests
checks / unit (pull_request) Successful in 34m52s
infra-pin / fresh (pull_request) Successful in 1s

- A price-provider site with no fixed tariff is not a gate (its plan never
  sets `cheap`); DECISIONS §3 says so and a test pins it.
- The fixed-tariff check is worked out once an hour, not every tick.
- test_maint13: run() steps really are `step` minutes; the long loops use
  5-minute steps (the per-tick cap); wall backstop checked "not before".
- test_safety93: the drain bound is the rig's configured drain rate.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-10-08 12:03:55 +02:00
co-authored by Claude Opus 5.5
parent f7b83cc75c
commit 6836f61bd4
4 changed files with 67 additions and 16 deletions
@@ -67,7 +67,13 @@ holds the charge back, and `cheap` is always false there), in a cheap window, or
while the pack is really taking charge (battery power at or below -50 W, which is
sun outside cheap hours). It is false only when a gate exists, is shut, and the
pack is not charging; a pack asked for charge that delivers nothing then does not
count, which is the case the clock cannot judge. Only open ticks add to `open_min`; one tick
count, which is the case the clock cannot judge. A site with a price provider
(TARIFF-11) and no fixed tariff counts as having no gate: the provider's plan
reaches only the Tariff row, never `cheap`, so no cheap window ever opens a grid
top-up there and only the sun charges the pack, as on a site with no tariff. Its
time counts in full. When a provider plan starts to drive `cheap`,
`_price_gated` must become true for it. Whether a fixed tariff is set up is
worked out once an hour, not on every tick. Only open ticks add to `open_min`; one tick
adds at most 5 min, so a gap (add-on down) adds nothing. The stall wait pauses
while the gate is closed. The accounting is written to the state file at most
every 5 min (`charge_track`); a restart loses at most that. A state file from
+14 -3
View File
@@ -1189,6 +1189,7 @@ class Controller:
self.peak_fc = None
self.cheap = False
self._price_gated = False # MAINT-13: is a price gate set up
self._gated_key = None # MAINT-13: (options, hour) of the cache
# TARIFF-03. One line of prose for the status page saying WHICH tariff
# window we are in and why it is or is not cheap - so "Cheap window:
# no" is an evidenced answer rather than a bare no.
@@ -3337,9 +3338,9 @@ class Controller:
# ⚠️ AND IT CANNOT BE BOTH. validate.py refuses static_profile
# alongside the two Home Assistant entities, because this `if` picks
# one and the loser is silent.
self.cheap, self.tariff_words = static_status(
o, datetime.now(timezone.utc))
self._price_gated = static_gated(o, datetime.now(timezone.utc))
_now = datetime.now(timezone.utc)
self.cheap, self.tariff_words = static_status(o, _now)
self._price_gated = self._static_gated(o, _now)
# ⚠️ TARIFF-11. THE PROVIDER PLAN REACHES THE *Tariff* ROW HERE, AND
# THIS IS THE ONLY PLACE THE TWO SOURCES MEET. Everything above is the
@@ -3878,6 +3879,16 @@ class Controller:
inv.refusal_note())]
if n]
def _static_gated(self, o: dict, now: datetime) -> bool:
"""`static_gated()`, worked out once an hour: it builds the same
month-long plan as `static_status()` (about 20 ms with a profile), and
whether a fixed tariff is set up does not change from tick to tick
(options change only with a restart)."""
key = (id(o), now.strftime("%Y-%m-%d %H"))
if key != self._gated_key:
self._gated_key, self._gated = key, static_gated(o, now)
return self._gated
def _charge_gate_open(self, inv) -> bool:
"""MAINT-13: may this pack charge now, for the maintenance timeout?
+40 -10
View File
@@ -82,8 +82,8 @@ def run(m, start, minutes, soc, gate=True, step=1):
Returns (the last result, the time after the run, the first non-CHARGE result)."""
t, res, out = start, None, None
for i in range(0, minutes, step):
t = start + i * step * MIN
s = soc(i * step) if callable(soc) else soc
t = start + i * MIN
s = soc(i) if callable(soc) else soc
res = m.tick(t, s, gate_open=gate)
if out is None and res.phase != CHARGE:
out = (res, t)
@@ -215,20 +215,23 @@ check("a drain that times out is a failure too, with the same back-off",
print("5. only the minutes the pack was allowed to charge count")
m = in_charge()
res, t, out = run(m, T0, CHARGE_TIMEOUT_MIN * 2, 70.0, gate=False)
# 5 min steps: one tick counts at most 5 min, so this is the same count as
# 1 min steps in a fifth of the ticks.
res, t, out = run(m, T0, CHARGE_TIMEOUT_MIN * 2, 70.0, gate=False, step=5)
check("72 h with the gate closed: not timed out", out is None and m.phase == CHARGE)
res, t, out = run(m, t, CHARGE_TIMEOUT_MIN - 5, 70.0)
res, t, out = run(m, t, CHARGE_TIMEOUT_MIN - 5, 70.0, step=5)
check("...and 35 h 55 min open on top: still charging", out is None)
res, t, out = run(m, t, 10, 70.0)
check("...36 h of open time in all: the charge fails", out and out[0].failed == "charge")
m = in_charge()
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 5, 70.0, gate=False, step=5)
check("a gate that never opens still ends in a failure after 7 days",
out and out[0].failed == "charge")
WALL = T0 + CHARGE_WALL_TIMEOUT_MIN * MIN
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 70.0, gate=False, step=5)
check("a gate that never opens still ends in a failure after 7 days (not before)",
out and out[0].failed == "charge" and WALL < out[1] <= WALL + 5 * MIN)
m = in_charge()
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 5, 98.0, gate=False, step=5)
res, t, out = run(m, T0, CHARGE_WALL_TIMEOUT_MIN + 10, 98.0, gate=False, step=5)
check("...or in a complete charge when the pack is near full",
out and out[0].phase == HOLD)
out and out[0].phase == HOLD and WALL < out[1] <= WALL + 5 * MIN)
m = in_charge()
res, t, out = run(m, T0, 10, 70.0)
before = m._trk["open_min"]
@@ -256,7 +259,7 @@ with tempfile.TemporaryDirectory() as d:
m_b.phase == CHARGE
and open_before - 6 <= m_b._trk["open_min"] <= open_before + 2
and m_b._trk["open_min"] < 60)
_, t2, out = run(m_b, t + 2 * MIN, CHARGE_TIMEOUT_MIN - 30, 70.0)
_, t2, out = run(m_b, t + 2 * MIN, CHARGE_TIMEOUT_MIN - 30, 70.0, step=5)
check("...so the timeout comes after 36 h in all, not 36 h from the restart",
out is not None and out[0].failed == "charge")
m = Maintenance(CFG, Store(path))
@@ -454,6 +457,19 @@ m = put_in_charge(c, 0, 40, CHARGE_TIMEOUT_MIN + 1)
one_cycle(c)
check("...and a pack past its charging time there fails at once (not 7 days)",
m.phase == IDLE and len(notes(h)) == 1)
# a site with a price provider (TARIFF-11) and no fixed tariff: the provider's
# plan reaches only the Tariff row, never `cheap`, so no cheap window ever
# opens a grid top-up there. Like the site above, nothing gate-like holds the
# charge back, and the time counts.
PROVIDER = dict(NOTARIFF, price_provider="generic_dayahead", static_profile="")
c, h = controller(PROVIDER, False)
m = put_in_charge(c, 0, 5, 100.0)
one_cycle(c)
got = m._trk["open_min"] - 100.0
check("N=1, price provider and no fixed tariff: not a gate (`cheap` is never "
f"set from the provider), so the 3 minutes count (+{got:.1f})",
c._price_gated is False and not c.cheap
and c._charge_gate_open(c.inverters[0]) is True and 2.5 < got < 3.5)
def read(c):
asyncio.run(c.read_inputs())
@@ -483,6 +499,20 @@ check("a fixed tariff set up counts as a gate: outside its cheap hours a pack "
"that is not charging is closed, inside them it is open",
c._price_gated is True
and c._charge_gate_open(c.inverters[0]) is c.cheap)
import app.main as main_mod # noqa: E402
_real_gated, _calls = main_mod.static_gated, []
main_mod.static_gated = lambda o, now: _calls.append(now) or _real_gated(o, now)
try:
c._gated_key = None
read(c)
read(c)
read(c)
c._static_gated(c.o, datetime.now(UTC) + timedelta(hours=1))
finally:
main_mod.static_gated = _real_gated
check("...worked out once an hour, not on every tick (3 reads in one hour = 1 "
f"build; a new hour = 1 more): {len(_calls)} builds",
len(_calls) == 2 and c._price_gated is True)
# the save timer is reset on a phase change
mm = in_charge()
+6 -2
View File
@@ -265,13 +265,17 @@ check("timeout with B due: the charge ends at 1780 s and A is not restarted",
and c.maints[0].phase == IDLE
and c.maints[0].backoff_until(rig.BASE + timedelta(seconds=1800))
is not None)
# A command below 0 W is a charge, so B's commands must stay at or above 0;
# the drain rate is the one this rig's controller was configured with.
drain_w = c.maints[1].cfg.discharge_w
print(f" B drain rate configured on the rig: {drain_w:.0f} W")
check("⭐ timeout with B due: no battery charges from the grid after it",
charging_hi(rows, 1780, 1798, hi1) == 0
and min(cmd(r)["b"] for r in rows if r[0] >= 1780) >= 0.0)
check("...B takes the slot and begins its own drain, which is the only large "
"step, to the drain rate and no higher",
"step, to the configured drain rate and no higher",
c.maints[1].phase == DRAIN
and max(cmd(r)["b"] for r in rows if r[0] >= 1780) <= 2000.0
and max(cmd(r)["b"] for r in rows if r[0] >= 1780) <= drain_w