diff --git a/goodwe_controller/CHANGELOG.md b/goodwe_controller/CHANGELOG.md index 304cd96..0cb16a9 100644 --- a/goodwe_controller/CHANGELOG.md +++ b/goodwe_controller/CHANGELOG.md @@ -1,5 +1,45 @@ # Changelog +## 0.8.0 + +⚠️ **`slew_w` CHANGED MEANING, AND THAT IS WHY THIS IS A MINOR BUMP.** +[[SAFETY-39]] makes the ramp limit a **ratio to the site rail** rather than an +absolute number of watts, and makes `slew_w: 0` mean *follow the rail* instead +of *no limit*. Two consequences for an existing config: + +- A config that leaves `slew_w` at `0` now gets the derived rail-proportional + limit. This is the intended fix - the live install was overshooting because + its `slew_w` had been derived against a 1500 W clamp and was running against a + 5000 W one. +- ⚠️ **A config that sets `slew_w` explicitly above `SLEW_RAIL_FRAC` x the roster + sum is now REFUSED at startup** by validator rule 10. `SLEW_RAIL_FRAC` is + `LOOP_TICK_S / PLANT_SETTLE_S` = 2/18. On a 5000 W single-inverter install the + ceiling is therefore about 555 W; the reference install runs `slew_w: 400` and + is unaffected. + +CFG-04's rule again, and PKG-06's: the Supervisor keys the built image by +`version:`, so shipping a schema or semantic change without a bump means +`ha apps update` is a silent no-op and nobody reads the new rule. **Six merges +accumulated behind an unbumped 0.7.0 before this was caught a second time** - +the check that would have caught it automatically is still not written, and that +gap is the standing content of PKG-06's follow-up. + +Contents, in merge order since 0.7.0 (`bbc903b`): + +| | | +|---|---| +| `9e42cec` | CI-06 - `test_peakguard.py` answered two of its checks with the wall clock | +| `24c3d87` | SAFETY-38 - pin `site_standing` with shares that cannot answer for the site | +| `a4290d3` | SAFETY-39 - `slew_w` becomes a ratio to the rail; validator rule 10 | +| `c8dcb38` | SAFETY-37 - a stale reading is `None`, and arrival cannot be what says so | +| `0581648` | SAFETY-13 - the output freeze gets a bounded exit, and only where it needs one | +| `464d398` | SAFETY-42 - a unit that stops delivering its share is no longer invisible | + +⚠️ **SAFETY-13 ships a disclosed residual.** Its bounded freeze-exit shows 0 +spurious releases on the sweep's measured-plant slice but **2 of 272 on a finer +grid**. The shipped documentation carries the 2-of-272 figure rather than the +flattering one, deliberately. + ## 0.7.0 ⚠️ **SCHEMA CHANGE, AND IT IS WHY THIS IS A MINOR BUMP RATHER THAN A PATCH.** @@ -29,7 +69,19 @@ is a defect in this file, not in the release: the deployed 0.6.0 is `2d025ee` an the table above is what is new since it. Splitting it retroactively would mean guessing a boundary; saying so is more useful than a guess. -## Unreleased +## Detail notes — accumulated, NOT a separate release + +⚠️ **THIS HEADING USED TO SAY "Unreleased" AND IT WAS WRONG.** Everything below +has SHIPPED. The section accumulated across 0.6.0, 0.7.0 and 0.8.0 because each +release was cut without clearing it, so it names tickets from all three +([[SAFETY-18]] and [[SAFETY-30]] from the 0.6.0 era through [[SAFETY-42]] in +0.8.0). A reader who trusted the old heading would have concluded that shipped, +running behaviour was still pending — and there was a SECOND heading saying the +same thing further down, from the 0.4.x era. + +Retitled rather than re-sorted, on purpose: splitting ~3000 lines by release is +real work that does not belong inside a version bump, where it would bury the +one line that changes what the Supervisor installs. Card PKG-08 carries it. ⚠️ **THE OUTPUT FREEZE NOW HAS AN EXIT, AND ONLY WHERE IT CANNOT END ON ITS OWN ([[SAFETY-13]]).** While the loop is frozen the command's magnitude may fall but @@ -3381,7 +3433,12 @@ human to read rather than alarmed on - at a converged -10 W a 1 Wh register need about six minutes to move, so any threshold would false-trip at the target operating point. -## Unreleased +## Detail notes from the 0.4.x era — NOT unreleased + +⚠️ Retitled with the same correction as the section above: TEL-05 and the +entries under this heading shipped long ago. Two headings in one file both +claiming "Unreleased" is how a reader ends up believing running behaviour is +still pending. **TEL-05.** A fourth `meter_source`, `homewizard_local`, which polls a HomeWizard P1's **own local API** (`GET /api/v1/data`) instead of watching a diff --git a/goodwe_controller/config.yaml b/goodwe_controller/config.yaml index f2b9333..ec8568a 100644 --- a/goodwe_controller/config.yaml +++ b/goodwe_controller/config.yaml @@ -1,5 +1,5 @@ name: GoodWe RS485 Controller -version: "0.7.0" +version: "0.8.0" slug: goodwe_controller description: >- Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart