Merge pull request 'SAFETY-52: a battery that refuses is asked for 0 W, with a 200 W probe every 15 min' (#141) from SAFETY-52-refused-hold into release/1.0
infra-pin / fresh (push) Successful in 1s

This commit was merged in pull request #141.
This commit is contained in:
2026-09-27 18:21:21 +02:00
11 changed files with 894 additions and 11 deletions
@@ -0,0 +1,110 @@
# SAFETY-52 - a battery that refuses is asked for 0 W
**Decided 2026-09-27 by the owner, on the phase A plan (option D3). All four
questions answered yes.**
## The defect
At the BMS cut-out the battery gives ~0 W whatever it is asked. The saturation
freeze (`control.py`, `frozen`) then holds the request where it stood, and its
SAFETY-13 exit cannot fire, because a reading of ~0 against a large ask lies
inside the interval a limit can produce. The request stood at +5000 W for
11.87 h on 2026-09-06 and at +1940 W for 3 h 55 m on the bus on 2026-09-19. It
moved again only when the grid error changed sign. SAFETY-48's lead cap only
changes where `i_w` parks (one slew step ahead instead of at the rail). When
the request moved after the reading went flat, the stale-reading gate won
instead and ran SAFETY-59's ~70 s trip cycle.
## What was decided
1. **A refused direction is held at 0 W**, reason `battery refuses`. It engages
in `compute()` when the freeze has held `SETTLE_CYCLES` and the reading is
below `REFUSED_BELOW_W` (100 W, the probe's own answer) against an ask beyond
`saturation_w`. The drop to 0 skips
the slew limit (it only removes an ask nobody meets). The direction is
carried like `sat_count` (`refused=`, `Decision.refused`).
2. **A 200 W probe every 15 minutes, 34 s long** (`PROBE_W`, `PROBE_EVERY_S`,
`PROBE_S`; twice `BATT_OBLIGED_S`). A reading of at least 100 W in the held
direction ends the refusal, during a probe or not. 200 W is below `freshness.MOVE_W` (250 W), so a probe cannot arm
the gate. The clock is main.py's `now_mono`; `compute()` stays clockless.
3. **A gate trip while the loop is frozen on a ~0 W reading is a refusal** for
control (`Controller._refusal_from_stale`). This is what stops the ~70 s
cycle. The log keeps SAFETY-56's two-explanation wording.
4. **No SoC in the loop.** SAFETY-25 Option A stands. Nothing reads SoC.
Other exits: the loop wants the other direction (charge is accepted at the
floor), control stopped or started, another writer on the wire (the arbiter
reseed). A gap in the readings keeps the refusal, because the gate's own stop is
what seeds it.
**One inverter only.** At N>1, OPT-09's `pack` limit already closes an empty
battery's discharge end and moves its share. There, a one-unit gate trip must
not refuse the site. `compute()` is passed `refused=None` there, and that path
is release/1.0's law unchanged (the `i_w=None` equivalence sweep in
`test_control.py` still holds).
## Evidence
`test_refusal.py` drives the real Controller and gate (the 09-06 and 09-19
shapes, recovery with no sign change, the probe cadence, every exit).
`tools/replay_refusal.py` replays the 16-day capture, same model as
`replay_recorded_loop.py`, and should be read for deltas:
| plant | law | gate trips | request >1 kW above delivery | longest held | import / export kWh | worst 15-min |
|---|---|---|---|---|---|---|
| fitted | old | 85 | 113.3 h | 16.57 h | 112.0 / 35.2 | 3434 W |
| fitted | new | 130 (133 after review) | 11.4 h | 0.21 h | 112.3 / 35.4 | 3456 W |
| offset 0 W | old | 1010 | 102.2 h | 16.58 h | 112.0 / 35.2 | 3434 W |
| offset 0 W | new | 85 | 6.1 h | 0.33 h | 111.9 / 35.1 | 3434 W |
**Traced in review (#141).** The +22 W worst quarter is the old law's worst
quarter too. There the old law stands at +2060 W on a pack giving 0 W, and the
new law asks 0 W, which the fitted plant answers with its -22 W offset: 22 W
charged from the grid. The fit above the floor reads `batt = cmd - 28 W`, so a
real inverter asked 0 W may do the same. Of the 71 new-law trips with no
old-law trip within 2 min, 59 come 85-97 s after an answered probe. The offset has lifted the modelled pack
just above its floor, the probe is answered, control ramps, the pack empties
again mid-ramp, and the gate trips, which re-seeds the hold. The other 12
follow an other-direction exit the same way. On a site this is one
`STALE_READING` ERROR line per answered probe at most, and only on a battery
that answers a probe and then cuts out again. Catching the re-cut before the
gate needs a faster engage than `SETTLE_CYCLES`, which accuses a healthy slow
battery, so it is left to SAFETY-58/59. After the review changes below the
fitted-plant row reads 133 trips (the delivery exit now also catches answers
that arrive after the probe window); the other figures are unchanged. Rejected alternatives and their figures are in
the phase A plan: bounding the integrator by demand made the worst quarter
+541 W worse or cycled the gate 3368 times, and an SoC envelope needs the
configured floor to be right and needs SoC.
## Review changes (#141)
- **"Gives nothing" is below 100 W, not below 500 W.** At `saturation_w` a
battery derated to 100-499 W (cold, a tapering battery) was held at 0 W for
~93 % of the time: 300 W derated gave 86 Wh in 4 h against 1 200 Wh on the
old law. The capture has 0.11 h in that band, so the replay does not move.
- **Any delivery ends the hold, not only an answered probe.** With
`meter_poll_s: 1` the 12 cycles last 12 s, less than a healthy battery's
reading lag (up to `BATT_OBLIGED_S`, 17 s). That engaged on a healthy step and
held it for 15 min. Now the late reading ends it within seconds (2 s held in
`test_refusal.py` part 5b).
- **N>1 is stated as a limit in DOCS.** The pack limit there covers an empty
battery only when its cut-out level is configured right.
## Not covered
A battery that gives a steady part of the ask (e.g. a 500 W keep-alive) is a
genuine limit (SAFETY-13 case a) and still holds its request.
## What SAFETY-58 and SAFETY-59 must take into account
- **SAFETY-58** (the first read after a rest trips at once): a probe never arms
the gate (200 < 250 W), but the refusal seeding reads the trip. If 58 delays
the first verdict, the seed arrives later. The 09-19 shape then needs the
compute-side engagement (12 cycles) to win, which it does only while the
request stands still. Keep `test_refusal.py` part 4 green.
- **SAFETY-59** (DOCS says a ~70 s pattern proves a failed register): with this
change a refusing battery no longer produces the pattern at one inverter. The
DOCS text should say so, and that the `battery refuses` reason is the
discriminator the add-on now has. At N>1 the old pattern can still occur.
- If either changes `MOVE_W`, `PROBE_W` must stay below it.
`test_refusal.py` part 2 checks the inequality.
+22 -1
View File
@@ -526,7 +526,7 @@ accumulator is doing:
| `Loop integrator lead` | W | that value minus **the command it was computed against**, i.e. the command the previous cycle left standing | | `Loop integrator lead` | W | that value minus **the command it was computed against**, i.e. the command the previous cycle left standing |
| `Loop reason` | — | the law's own word for this cycle | | `Loop reason` | — | the law's own word for this cycle |
`Loop reason` takes one of eight values: `Loop reason` takes one of ten values:
| value | what happened | | value | what happened |
|---|---| |---|---|
@@ -538,6 +538,27 @@ accumulator is doing:
| `saturated-freeze` | the inverter is not following, so the command's magnitude may fall but not rise | | `saturated-freeze` | the inverter is not following, so the command's magnitude may fall but not rise |
| `freeze-released` | the freeze had run out of plant-shaped explanations and the command was let move again | | `freeze-released` | the freeze had run out of plant-shaped explanations and the command was let move again |
| `not-running` | control is stopped **and** shadow mode is off, so the loop did not run | | `not-running` | control is stopped **and** shadow mode is off, so the loop did not run |
| `battery refuses` | the battery gave less than 100 W for 12 cycles (a minute at a 5-second meter) while asked for more than 500 W, so the add-on asks 0 W in that direction (see below) |
| `battery probe` | the add-on asks 200 W to test whether a refusing battery gives power again |
**When the battery refuses.** At its cut-out level the battery gives nothing,
whatever it is asked. The add-on then asks 0 W instead of repeating its last
request, and the `Why` row reads *The battery refuses to give power: 0 W*. Every
15 minutes it asks 200 W for about half a minute. Control resumes as soon as
the battery gives 100 W or more, when the grid needs charging instead, and when
control is stopped or started. 200 W is below the 250 W the stale-reading check
needs, so a test never trips it. A battery that gives some power, even 100 W,
is not refusing and keeps its request.
⚠️ **One inverter only.** With several inverters this hold is off. There, the
battery level limit moves an empty battery's share to the others, but only if
its “Battery cut-out level” matches where the battery really stops. A battery
that refuses at another level, or for another reason (cold, a battery fault),
can still hold its last request until the grid starts to export.
*For installers:* SAFETY-52. The event log reads `BATTERY REFUSES …` and
`BATTERY REFUSES ENDED: …`, and the INFO line ends in `BATTERY_REFUSES`.
`DECISIONS/SAFETY-52-a-battery-that-refuses.md` has the replay figures.
⚠️ **`Loop reason` is not the `Why` row on the status page, and the two will ⚠️ **`Loop reason` is not the `Why` row on the status page, and the two will
often disagree.** `Why` is the *arbiter's* answer in words — *Keeping the grid often disagree.** `Why` is the *arbiter's* answer in words — *Keeping the grid
+58 -1
View File
@@ -265,6 +265,34 @@ _SAT_COUNT_CAP = SETTLE_CYCLES + 1 # 13
# `slew_limit_w()` and therefore with the rail. # `slew_limit_w()` and therefore with the rail.
SLEW_LEAD_STEPS = 1 SLEW_LEAD_STEPS = 1
# ---------------------------------------------------------------------------
# SAFETY-52. A BATTERY THAT REFUSES IS ASKED FOR 0 W, NOT HELD AT ITS LAST ASK.
#
# At the BMS cut-out the pack delivers ~0 W whatever it is asked, so the
# saturation freeze below holds the command where it stood (the recorded
# 09-06 case: +5000 W for 11.87 h) until the grid error changes sign. The
# freeze's own exit cannot help: a reading of ~0 against a large ask is inside
# the interval a limit can produce. So a refused DIRECTION is held at 0 W,
# carried between cycles like `sat_count`, and left again when the loop wants
# the other direction, when a small probe is answered, or when the caller
# resets it (stop, start, another writer). The record is DECISIONS/SAFETY-52.
#
# PROBE_W is below freshness.MOVE_W (250 W) on purpose: a probe that small can
# never arm the stale-reading gate, so it cannot start the gate's ~70 s cycle.
# test_refusal.py pins the inequality. The cadence and length are the owner's
# 2026-09-27 answer (every 15 minutes) and freshness.BATT_OBLIGED_S twice over
# (17 s is how long a healthy reading needs to show a command).
REFUSED = "battery refuses"
PROBING = "battery probe"
PROBE_W = 200.0
PROBE_ANSWER_W = PROBE_W / 2
# "Gives nothing" is below the probe's own answer, not below `saturation_w`: a
# pack derated to 100-499 W is a limit, and at 500 W it kept ~7 % of its power
# (review of #141). The capture's refusals read -4 W.
REFUSED_BELOW_W = PROBE_ANSWER_W
PROBE_EVERY_S = 900.0
PROBE_S = 34.0
@dataclass(frozen=True) @dataclass(frozen=True)
class Tuning: class Tuning:
@@ -346,6 +374,9 @@ class Decision:
i_bound_w: float = 0.0 i_bound_w: float = 0.0
requested_w: float = 0.0 requested_w: float = 0.0
clamped_w: float = 0.0 clamped_w: float = 0.0
# SAFETY-52. The refused direction to carry back in (+1 discharge, -1
# charge, 0 none), or None when the caller does not carry it.
refused: int | None = None
def slew_limit_w(tuning: Tuning) -> float: def slew_limit_w(tuning: Tuning) -> float:
@@ -442,6 +473,8 @@ def compute(
tuning: Tuning, tuning: Tuning,
sat_count: int = 0, sat_count: int = 0,
i_w: float | None = None, i_w: float | None = None,
refused: int | None = None,
probe: bool = False,
) -> Decision: ) -> Decision:
"""One control cycle. A cycle is one meter update (~5 s on a HomeWizard P1). """One control cycle. A cycle is one meter update (~5 s on a HomeWizard P1).
@@ -449,6 +482,9 @@ def compute(
`grid_w` net grid power, + = importing `grid_w` net grid power, + = importing
`actual_w` what the inverter reports it is doing, + = discharging `actual_w` what the inverter reports it is doing, + = discharging
`i_w` the carried integrator, or None to seed it from `prev_w` `i_w` the carried integrator, or None to seed it from `prev_w`
`refused` SAFETY-52's carried refused direction, or None to leave it out
(the `i_w=None` equivalence path does)
`probe` the caller's clock says a refused direction may try PROBE_W now
""" """
reason = "tracking" reason = "tracking"
@@ -739,6 +775,27 @@ def compute(
target = min(target, prev_w) if prev_w > 0 else max(target, prev_w) target = min(target, prev_w) if prev_w > 0 else max(target, prev_w)
reason = "saturated-freeze" reason = "saturated-freeze"
# --- SAFETY-52: a refused direction is held at 0 W ----------------------
# Engages only where the freeze has held for SETTLE_CYCLES and the unit
# delivers ~nothing: a reading below REFUSED_BELOW_W against an ask beyond
# `saturation_w` is a refusal, not a slow plant. The drop to 0 skips the slew
# limit because it only removes an ask the battery is not meeting.
if refused is not None:
if (refused == 0 and frozen and sat_count >= SETTLE_CYCLES
and abs(prev_w) > tuning.saturation_w
and abs(actual_w) < REFUSED_BELOW_W):
refused = 1 if prev_w > 0 else -1
if refused and refused * i_w < 0:
refused = 0 # the loop wants the other way
elif refused and refused * actual_w >= PROBE_ANSWER_W:
refused = 0 # it delivers: a probe answered,
# or a slow reading arriving
elif refused:
wants = refused * i_w > 0
i_w = 0.0
target = refused * PROBE_W if probe and wants else 0.0
reason = PROBING if probe and wants else REFUSED
# --- quantise ---------------------------------------------------------- # --- quantise ----------------------------------------------------------
# 10 W. The register is 1 W and the inverter reports at 1 W, but its # 10 W. The register is 1 W and the inverter reports at 1 W, but its
# response lands on a coarser ladder (~17.6 W measured at ~900 W, consistent # response lands on a coarser ladder (~17.6 W measured at ~900 W, consistent
@@ -749,7 +806,7 @@ def compute(
return Decision(float(target), sat_count, frozen, reason, float(i_w), return Decision(float(target), sat_count, frozen, reason, float(i_w),
i_clamped, clamped, float(i_bound_w), float(want), i_clamped, clamped, float(i_bound_w), float(want),
float(clamped_w)) float(clamped_w), refused)
def maintenance_charge_floor( def maintenance_charge_floor(
+94
View File
@@ -39,6 +39,7 @@ from .arbiter import (
P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY, P_LOOP, P_MAINT_SHAPE, P_MAINTENANCE, P_PEAK, P_SAFETY,
Claim, Resolution, actuator_for, resolve, Claim, Resolution, actuator_for, resolve,
) )
from . import control as _ctl
from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk from .control import Tuning, compute, maintenance_charge_floor, peak_at_risk
from .delivery import ( from .delivery import (
DELIVERY_OPTION_DEFAULTS, DeliveryConfig, UnitDelivery, DELIVERY_OPTION_DEFAULTS, DeliveryConfig, UnitDelivery,
@@ -241,6 +242,10 @@ def why_key(winner: str, claims) -> str:
disagreement"). A failsafe with no claim of its own is the arbiter's "no disagreement"). A failsafe with no claim of its own is the arbiter's "no
claim was made", or main.py's refusal to split the power ("unsplit"). claim was made", or main.py's refusal to split the power ("unsplit").
""" """
if winner == "loop":
# SAFETY-52: a loop holding a refused direction says so.
return next((c.reason for c in claims if c.source == "loop"
and c.reason in (_ctl.REFUSED, _ctl.PROBING)), winner)
if winner in ("safety", "failsafe"): if winner in ("safety", "failsafe"):
return next((c.reason for c in claims return next((c.reason for c in claims
if c.source == winner and c.kind == "set"), if c.source == winner and c.kind == "set"),
@@ -925,6 +930,12 @@ class Controller:
self.target = 0.0 self.target = 0.0
self.sat_count = 0 self.sat_count = 0
self.i_w = 0.0 # the loop's integrator, carried between cycles self.i_w = 0.0 # the loop's integrator, carried between cycles
# SAFETY-52. The direction the battery refuses (+1 / -1 / 0), carried
# like `i_w`, and when the refusal (or its last probe) started.
self.batt_refused = 0
self.batt_refused_at = None
self._now_mono = None
self._refusal_auto = False
# TEL-10. What the last cycle's loop did, kept for publication. Seeded # TEL-10. What the last cycle's loop did, kept for publication. Seeded
# to the SAME values the "stopped or blind" branch of `cycle()` writes, # to the SAME values the "stopped or blind" branch of `cycle()` writes,
# because before the first cycle the loop has not run - which is the # because before the first cycle the loop has not run - which is the
@@ -1058,6 +1069,69 @@ class Controller:
self.loop_pass_mono = None self.loop_pass_mono = None
# -- helpers ------------------------------------------------------------- # -- helpers -------------------------------------------------------------
# --- SAFETY-52: a battery that refuses is asked for 0 W ------------------
def _refusal_probe(self) -> bool:
"""True while a refused direction may try `PROBE_W` (every 15 min)."""
if (not self.batt_refused or self.batt_refused_at is None
or self._now_mono is None):
return False
held = self._now_mono - self.batt_refused_at
if held >= _ctl.PROBE_EVERY_S + _ctl.PROBE_S:
self.batt_refused_at = self._now_mono
return False
return held >= _ctl.PROBE_EVERY_S
def _refusal_start(self, sign: int, evidence: str) -> None:
self.batt_refused = sign
self.batt_refused_at = self._now_mono
self.log_event(f"BATTERY REFUSES {evidence}",
hint=messages.hint("battery_refuses"))
_LOG.info("The battery refuses to give power, so the add-on asks 0 W "
"and tries %.0f W every %.0f minutes: BATTERY_REFUSES.",
_ctl.PROBE_W, _ctl.PROBE_EVERY_S / 60)
_LOG.debug("Evidence: BATTERY_REFUSES: %s.", evidence)
def _refusal_end(self, why: str) -> None:
if not self.batt_refused:
return
self.batt_refused, self.batt_refused_at = 0, None
self.log_event(f"BATTERY REFUSES ENDED: {why}",
hint=messages.hint("battery_gives"))
_LOG.info("The battery refusal ends, control asks for power again: %s.",
why)
def _refusal_update(self, decision, asked_w, batt_w, probe) -> None:
"""Follow `compute()`'s carried refused direction, and say so."""
now = decision.refused or 0
if now and not self.batt_refused:
self._refusal_start(now, f"asked {asked_w:+.0f} W, the battery "
f"gave {batt_w:+.0f} W for "
f"{decision.sat_count} cycles")
elif self.batt_refused and not now:
gave = self.batt_refused * batt_w >= _ctl.PROBE_ANSWER_W
self._refusal_end("the probe was answered" if gave and probe
else "the battery gives power" if gave
else "the grid now asks the other direction")
def _refusal_from_stale(self, inv, now_mono) -> None:
"""A stale-reading stop while the loop is frozen on ~0 W is a refusal.
Only at one inverter: with several, one empty battery must not stop the
site (OPT-09's pack limit moves its share to the others).
"""
t = self.tuning
standing = inv.standing_w()
if (len(self.inverters) == 1 and (self.auto or self.shadow)
and not self.batt_refused
and self.sat_count >= t.saturation_cycles
and inv.batt_fresh.held is not None
and abs(inv.batt_fresh.held) < _ctl.REFUSED_BELOW_W
and abs(standing) > t.saturation_w):
self._now_mono = now_mono
self._refusal_start(1 if standing > 0 else -1,
f"stale reading {inv.batt_fresh.held:+.0f} W "
f"while asked {standing:+.0f} W")
def log_event(self, msg: str, hint: str | None = None) -> None: def log_event(self, msg: str, hint: str | None = None) -> None:
"""`msg` goes on the action log, the add-on's own technical record. """`msg` goes on the action log, the add-on's own technical record.
`hint` is `messages.hint()`'s plain words for the same event, and is `hint` is `messages.hint()`'s plain words for the same event, and is
@@ -1840,6 +1914,7 @@ class Controller:
""" """
o = self.o o = self.o
now_mono = freshness.monotonic() if now_mono is None else float(now_mono) now_mono = freshness.monotonic() if now_mono is None else float(now_mono)
self._now_mono = now_mono
if self.p1_enabled: if self.p1_enabled:
# ⚠️ P1 is the only authoritative measurement of what the utility # ⚠️ P1 is the only authoritative measurement of what the utility
# sees (§5.1). When it is stale this is None, which falls into the # sees (§5.1). When it is stale this is None, which falls into the
@@ -2003,6 +2078,7 @@ class Controller:
if inv.batt_fresh.stale and not was_stale: if inv.batt_fresh.stale and not was_stale:
self.log_event(f"STALE {inv.name}: " + inv.batt_fresh.reason, self.log_event(f"STALE {inv.name}: " + inv.batt_fresh.reason,
hint=messages.hint("battery_stuck", unit=inv.name)) hint=messages.hint("battery_stuck", unit=inv.name))
self._refusal_from_stale(inv, now_mono)
# ⚠️ SAFETY-57 REWROTE THE LAST SENTENCE OF THIS LINE AND NOTHING # ⚠️ SAFETY-57 REWROTE THE LAST SENTENCE OF THIS LINE AND NOTHING
# ELSE IN IT. The escape clause used to read "It clears itself the # ELSE IN IT. The escape clause used to read "It clears itself the
# moment the register reports a different value", full stop - and # moment the register reports a different value", full stop - and
@@ -3340,6 +3416,12 @@ class Controller:
# loop should be. It is safe because the loop's `prev_w` is # loop should be. It is safe because the loop's `prev_w` is
# `self.target`, which the end of this method re-seeds to what is # `self.target`, which the end of this method re-seeds to what is
# actually standing on the wire. # actually standing on the wire.
# SAFETY-52: a refusal learned while control ran does not survive a
# stop or a start (shadow mode keeps the loop running when stopped).
if bool(self.auto) != self._refusal_auto:
self._refusal_auto = bool(self.auto)
self._refusal_end("control started" if self.auto
else "control stopped")
if (self.auto or self.shadow) and self.inputs_ok: if (self.auto or self.shadow) and self.inputs_ok:
# ⚠️ prev is the ARBITER's last output, not the loop's own last # ⚠️ prev is the ARBITER's last output, not the loop's own last
# wish. If something outranked the loop, that is what the hardware # wish. If something outranked the loop, that is what the hardware
@@ -3357,6 +3439,13 @@ class Controller:
# stale period as power. # stale period as power.
if self.loop_w is None or self.target != self.loop_w: if self.loop_w is None or self.target != self.loop_w:
self.i_w = self.target self.i_w = self.target
# SAFETY-52: another writer overrode the loop, so a refusal learned
# against the loop's own ask no longer describes the wire. A gap
# (`loop_w` None: blind or stopped) keeps it: the stale-reading stop
# is what seeds it, and dropping it there restarts the ~70 s cycle.
if self.loop_w is not None and self.target != self.loop_w:
self._refusal_end("another writer")
probe = self._refusal_probe()
# ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF. # ⚠️ `actual_w` IS THE SITE SUM AND THAT IS DEV-02's OTHER HALF.
# The anti-windup test inside compute() is # The anti-windup test inside compute() is
# `abs(prev_w - actual_w) > saturation_w`, and `prev_w` is the SITE # `abs(prev_w - actual_w) > saturation_w`, and `prev_w` is the SITE
@@ -3385,6 +3474,10 @@ class Controller:
tuning=self.tuning, tuning=self.tuning,
sat_count=self.sat_count, sat_count=self.sat_count,
i_w=self.i_w, i_w=self.i_w,
# SAFETY-52 at one inverter only: with several, OPT-09's pack
# limit already closes an empty battery's discharge end.
refused=self.batt_refused if len(self.inverters) == 1 else None,
probe=probe,
) )
if decision.frozen and self.sat_count < self.tuning.saturation_cycles: if decision.frozen and self.sat_count < self.tuning.saturation_cycles:
self.log_event(f"saturation freeze ({self.target:.0f} W vs " self.log_event(f"saturation freeze ({self.target:.0f} W vs "
@@ -3393,6 +3486,7 @@ class Controller:
self.sat_count = decision.sat_count self.sat_count = decision.sat_count
self.i_w = decision.i_w self.i_w = decision.i_w
self.loop_w = decision.target_w self.loop_w = decision.target_w
self._refusal_update(decision, loop_prev, site_batt, probe)
# --- TEL-10 ------------------------------------------------------ # --- TEL-10 ------------------------------------------------------
# ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT # ⚠️ THE INTEGRATOR HAS NEVER LEFT THIS PROCESS, AND THAT IS WHAT
# THE CARD IS. `self.i_w` is carried between cycles and published # THE CARD IS. `self.i_w` is carried between cycles and published
+5
View File
@@ -802,6 +802,9 @@ WHY_WINNER = {
# failsafe winner. test_messages.py part 7 finds every one in the code. # failsafe winner. test_messages.py part 7 finds every one in the code.
"sign disagreement": "Safety stop, power went the wrong way", "sign disagreement": "Safety stop, power went the wrong way",
"unsplit": "The power could not be split, all at 0 W", "unsplit": "The power could not be split, all at 0 W",
# SAFETY-52: the loop's two words for a battery that gives nothing.
"battery refuses": "The battery refuses to give power",
"battery probe": "Testing if the battery gives power again",
} }
WHY_LIMIT = { WHY_LIMIT = {
"peak(quarter peak)": "the peak limit", "peak(quarter peak)": "the peak limit",
@@ -852,6 +855,8 @@ HINTS = {
"stop_restored": "{unit}: an earlier safety stop is back, it stays at 0 W", "stop_restored": "{unit}: an earlier safety stop is back, it stays at 0 W",
"battery_stuck": "{unit}: battery power reading stopped changing", "battery_stuck": "{unit}: battery power reading stopped changing",
"battery_back": "{unit}: battery power reading is used again", "battery_back": "{unit}: battery power reading is used again",
"battery_refuses": "The battery refuses to give power, the add-on asks 0 W",
"battery_gives": "The battery refusal ended, control asks for power again",
"bad_value": "The add-on made an invalid power value, inverters set to 0 W", "bad_value": "The add-on made an invalid power value, inverters set to 0 W",
"write_blocked": "{unit}: a power request was blocked, it is set to 0 W", "write_blocked": "{unit}: a power request was blocked, it is set to 0 W",
"all_blocked": "A power request was blocked, inverters set to 0 W", "all_blocked": "A power request was blocked, inverters set to 0 W",
+12 -3
View File
@@ -497,8 +497,13 @@ check(f"AC 1: NOT ONE of the {len(emitted)} values that reached the device "
# largest emitted value is what it is and not 5000 W. The clamp is what makes it # largest emitted value is what it is and not 5000 W. The clamp is what makes it
# bounded; the freeze is what makes it small. A check that read # bounded; the freeze is what makes it small. A check that read
# `max(emitted) == max_w` would have been asserting the freeze, not the clamp. # `max(emitted) == max_w` would have been asserting the freeze, not the clamp.
# SAFETY-52 re-baseline: an inverter reporting 0 W for SETTLE_CYCLES is a
# battery that refuses, so the command then drops to 0 W. The freeze still
# engaged first, and the event log says so.
check(f"...and the saturation freeze is what pins it at {max(emitted):,.0f} W " check(f"...and the saturation freeze is what pins it at {max(emitted):,.0f} W "
f"rather than the rail", ctl_r.sat_count >= ctl_r.tuning.saturation_cycles) f"rather than the rail",
any("saturation freeze" in e for e in ctl_r.events)
and max(emitted) < LIVE_MAX_W)
notes_r = clamp_notes(hass_r) notes_r = clamp_notes(hass_r)
print(f" the loop clamped on {ctl_r.clamp_wd.engagements} of {60} cycles, " print(f" the loop clamped on {ctl_r.clamp_wd.engagements} of {60} cycles, "
@@ -580,8 +585,12 @@ check("UX-07 item 1: during a bound episode an earlier over-rating count is "
# ⚠️ NOT A TRIP. 11.2's action is "clamp and alarm"; the loop keeps running and # ⚠️ NOT A TRIP. 11.2's action is "clamp and alarm"; the loop keeps running and
# keeps writing the clamped value. If a later cut changes that it must come here. # keeps writing the clamped value. If a later cut changes that it must come here.
check(f"it is NOT a trip - the command stands at {ctl_r.target:+.0f} W, not 0 W", # SAFETY-52: the loop itself now asks 0 W of an inverter that gives nothing,
ctl_r.target != 0.0 and ctl_r.target == hass_r.writes[-1]) # with its own reason. That is the loop's decision, not a stop.
check(f"it is NOT a trip - the command stands at {ctl_r.target:+.0f} W because "
f"the loop says '{ctl_r.loop_reason}', not because of a stop",
ctl_r.loop_reason == "battery refuses"
and ctl_r.target == hass_r.writes[-1])
check("...and the controller still reports itself running, not failsafe", check("...and the controller still reports itself running, not failsafe",
ctl_r.auto and not ctl_r.sign_wd.tripped) ctl_r.auto and not ctl_r.sign_wd.tripped)
+8 -3
View File
@@ -1147,8 +1147,10 @@ async def _one():
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt", "soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "max_w": 2000, "gain": 0.6, "meter_source": "off", "max_w": 2000, "gain": 0.6,
# ⚠️ THE SAME 1 s AS THE TWO-INVERTER FIXTURE, AND THAT IS WHAT # ⚠️ THE SAME 1 s AS THE TWO-INVERTER FIXTURE, AND THAT IS WHAT
# MAKES THIS SECTION NON-VACUOUS. The run below is 2 s of wall clock # MAKES THIS SECTION NON-VACUOUS. The run below is 1.1 s of wall
# against a 1 s window, so a hold is not what stops this firing - # clock against a 1 s window (SAFETY-52 shortened it from 2 s, and
# "the window was never even opened" below is what still makes it
# non-vacuous), so a hold is not what stops this firing -
# the reduction is. With a shipped-length hold "nothing was # the reduction is. With a shipped-length hold "nothing was
# reported" would be true of a fixture that simply ran out of time. # reported" would be true of a fixture that simply ran out of time.
"bms_soc_floor": _FLOOR_PCT, "delivery_hold_s": 1, "bms_soc_floor": _FLOOR_PCT, "delivery_hold_s": 1,
@@ -1158,7 +1160,10 @@ async def _one():
c.inverters[0].dev_min, c.inverters[0].dev_max = -2000.0, 2000.0 c.inverters[0].dev_min, c.inverters[0].dev_max = -2000.0, 2000.0
c.auto = True c.auto = True
hass.ctrl = c hass.ctrl = c
await _drive(c, n=20, dt=0.1) # SAFETY-52: from SETTLE_CYCLES of delivering nothing the loop asks 0 W
# (the battery refuses), so the run stops just before that. 11 cycles is
# still 1.1 s against the 1 s hold.
await _drive(c, n=11, dt=0.1)
return c, hass, store return c, hass, store
+6
View File
@@ -1399,6 +1399,7 @@ import logging # noqa: E402
from app import hass as _hass, p1 as _p1, validate as _validate, web as _web # noqa: E402 from app import hass as _hass, p1 as _p1, validate as _validate, web as _web # noqa: E402
from app.arbiter import Claim # noqa: E402 from app.arbiter import Claim # noqa: E402
from app.main import Controller, why_key # noqa: E402 from app.main import Controller, why_key # noqa: E402
from app import control as _control # noqa: E402
from app import main as _main # noqa: E402 from app import main as _main # noqa: E402
@@ -1585,6 +1586,11 @@ for _f in sorted(APP.glob("*.py")):
_keys = {why_key(s, [Claim.set(s, 0, 0.0, r)]) for s, r in _SOURCES} _keys = {why_key(s, [Claim.set(s, 0, 0.0, r)]) for s, r in _SOURCES}
_keys |= {why_key("failsafe", []), _keys |= {why_key("failsafe", []),
why_key("failsafe", [Claim.set("loop", 0, 1.0, "tracking")])} why_key("failsafe", [Claim.set("loop", 0, 1.0, "tracking")])}
# SAFETY-52: the loop's claim reason is computed, so the scan cannot see it.
_keys |= {why_key("loop", [Claim.set("loop", 0, 0.0, _r)])
for _r in (_control.REFUSED, _control.PROBING)}
check("...including the loop's two battery-refuses reasons, which get words of "
"their own", {_control.REFUSED, _control.PROBING} <= _keys)
check(f"the scan found the claims ({len(_SOURCES)}), including the latched " check(f"the scan found the claims ({len(_SOURCES)}), including the latched "
f"per-inverter stop the 2d test saw as 'Other'", f"per-inverter stop the 2d test saw as 'Other'",
("failsafe", "sign disagreement") in _SOURCES and len(_SOURCES) >= 8) ("failsafe", "sign disagreement") in _SOURCES and len(_SOURCES) >= 8)
+7 -3
View File
@@ -4412,12 +4412,16 @@ check(f"AC, AND THE WHOLE OF DEFECT 4: 'trading is off' and 'trading is on "
f"`off (arbitrage_enabled)` for both - naming an option that is `true` " f"`off (arbitrage_enabled)` for both - naming an option that is `true` "
f"in the options blob", f"in the options blob",
_T11_OFF[0]["Arbitrage"] != _T11_ON_HELD[0]["Arbitrage"]) _T11_OFF[0]["Arbitrage"] != _T11_ON_HELD[0]["Arbitrage"])
# ⚠️ THE "Why" ROW OF THE SAME RENDER, NOT A SECOND READ OF `why_words`. Since
# UX-10 the waiting sentence counts its seconds when it is read, so reading the
# property again here, after the other renders above, could cross a second
# ("1 second" in the row, "2 seconds" now) - CI run 953 on PR #141 did.
check(f"...and the armed-but-held row carries the CONTROL LOOP'S OWN REASON " check(f"...and the armed-but-held row carries the CONTROL LOOP'S OWN REASON "
f"({_T11_ON_HELD[1].why_words!r}), so the operator is told which input is " f"({_T11_ON_HELD[0]['Why']!r}), so the operator is told which input is "
f"missing rather than being sent to look at a switch that is already on. " f"missing rather than being sent to look at a switch that is already on. "
f"The reason comes from main.py, not from this file", f"The reason comes from main.py, not from this file",
_T11_ON_HELD[1].why_words _T11_ON_HELD[0]["Why"].startswith("A reading is missing")
and _T11_ON_HELD[1].why_words in _T11_ON_HELD[0]["Arbitrage"]) and _T11_ON_HELD[0]["Why"] in _T11_ON_HELD[0]["Arbitrage"])
check(f"...and a cycle that DID reach the step renders the strategy's own " check(f"...and a cycle that DID reach the step renders the strategy's own "
f"sentence - {_T11_ON_OK[1].arb.explain()[:50]!r} - rather than a " f"sentence - {_T11_ON_OK[1].arb.explain()[:50]!r} - rather than a "
f"re-derivation of it, which is the guarantee OPT-04 put on this row and " f"re-derivation of it, which is the guarantee OPT-04 put on this row and "
+475
View File
@@ -0,0 +1,475 @@
"""Runnable check for SAFETY-52. `python3 test_refusal.py`
A battery that refuses to give power (the BMS cut-out) used to leave the
command standing at its last ask for hours: +5000 W for 11.87 h on 2026-09-06,
+1940 W for 3 h 55 m on the bus on 2026-09-19. Now a refused direction is held
at 0 W, a 200 W probe asks every 15 minutes, and the refusal ends on charge, on
an answered probe, on stop/start and when another writer takes the wire.
DECISIONS/SAFETY-52 has the record and the replay figures.
Mutating the modules this file grades? Purge `__pycache__` first, or run
`tools/mutation_run.sh`, which does - see MUTATION.md.
Parts 1-5 drive the REAL `Controller` (read_inputs + cycle, the real
SAFETY-37/57 gate) against a scripted battery whose reading stands at exactly
-4 W for any request >= -4 W at the cut-out, and follows otherwise. Time is the
`now_mono` handed to `read_inputs()`, so 12 hours run in seconds. `OLD` runs the
same fixture with `refused=None` forced into `compute()` - release/1.0's law -
so every "new" figure is shown beside the one it replaces. Part 4 also runs
`compute()` alone, as the bus saw 09-19 before the gate existed.
Mutations, each on a copy of this tree purged of `__pycache__`, graded with
`python3 -B` over test_refusal, test_control, test_clamp, test_telemetry and
test_messages (MUTATION.md). Reds are failing checks, on this tree:
# mutation reds
-- ------------------------------------------------------- ---------------
R1 control.py: the engage `if` -> `if False and ...` 8 here + 1 clamp
(release/1.0's behaviour)
R2 control.py: the exit on the other direction removed 1
R3 control.py: the exit on an answered probe removed 2
R4 control.py: `PROBE_W = 300.0`, above the gate's 250 W 4
R5 control.py: the hold keeps the old target, not 0 W 4
R6 main.py: `_refusal_from_stale()` returns at once 1
R7 main.py: another writer no longer ends the refusal 1
R8 main.py: stop/start no longer ends the refusal 1
R9 main.py: the probe window never opens 4
R10 main.py: seed from a stale stop below `saturation_w` again, 1
not below REFUSED_BELOW_W (review of #141). The same mutation
in control.py's engage clause SURVIVES, and that is expected:
the delivery exit (R11) ends such a refusal in the same cycle.
R11 control.py: only an answered PROBE ends the refusal 2
(`and probe` back in the delivery exit; review of #141)
"""
import asyncio
import sys
from datetime import datetime, timedelta, timezone
from app import control, freshness
from app.control import PROBE_EVERY_S, PROBE_S, PROBE_W, REFUSED, PROBING
from app.main import Controller, why_key
from app.arbiter import Claim
from app import messages
fails = []
def check(name, cond):
print(f" {'ok ' if cond else 'FAIL'} {name}")
if not cond:
fails.append(name)
LIVE = {"max_w": 5000.0, "gain": 0.6, "slew_w": 400.0, "target_grid_w": -10.0,
"deadband_w": 15, "step_w": 10}
TICK = 5.0 # the meter's measured median tick (replay_recorded_loop)
CUT_W = -4.0 # what the register reads at the cut-out, 2026-09-06
H = 3600.0
BASE = datetime(2026, 9, 6, 19, 30, tzinfo=timezone.utc)
class _Store:
def __init__(self):
self.data = {}
def set(self, *a):
pass
def get_time(self, *a):
return None
class _Pub:
enabled = False
def publish(self, values):
pass
def close(self):
pass
class _Hass:
"""House load, and a battery that follows unless `cut(t)` says it refuses.
At the cut-out the reading is exactly CUT_W for any request >= CUT_W (a flat
register, which is what arms or does not arm the stale-reading gate). A
charge request is followed: the pack accepts charge at the floor.
`cap(t)` limits discharge while not cut (the 09-06 pack gave 4570 W at 10 %).
"""
def __init__(self, load, cut, cap=lambda t: 1e9):
self.load, self.cut, self.cap = load, cut, cap
self.t = 0.0
self.cmd = 0.0
self.writes = []
def batt(self):
if self.cut(self.t) and self.cmd >= CUT_W:
return CUT_W
return float(round(min(self.cmd, self.cap(self.t))))
async def limits(self, entity):
return (-LIVE["max_w"], LIVE["max_w"], 1.0)
async def number(self, entity, invert=False):
b = self.batt()
return {"sensor.grid": self.load(self.t) - b, "sensor.soc": 9.0,
"sensor.batt": b}.get(entity)
async def set_number(self, entity, value):
self.writes.append((self.t, float(value)))
self.cmd = float(value)
return True
async def call(self, *a):
return True
def run(load, cut, dur, cap=lambda t: 1e9, old=False, events=None):
"""Real cycles every TICK seconds of `now_mono`. `events[t] = fn(c)` pokes
the controller (stop, start, another writer) at that instant.
Returns [(t, grid, batt, setpoint, i_w, loop_reason, batt_refused)], the
number of gate trips, and the controller."""
async def go():
hass = _Hass(load, cut, cap)
c = Controller(dict(
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off", "heartbeat_s": 10, "stale_input_s": 15},
**LIVE), hass, _Store(), _Pub(), stop=asyncio.Event())
c.auto = True
c.dev_min, c.dev_max = -LIVE["max_w"], LIVE["max_w"]
import app.main as m
real, real_dt = m.compute, m.datetime
clock = [0.0]
class _DT(real_dt):
"""`cycle()`'s wall clock follows `now_mono`, so the 15 s input hold
and the gate's release run in simulated seconds too."""
@classmethod
def now(cls, tz=None):
return BASE + timedelta(seconds=clock[0])
m.datetime = _DT
if old:
m.compute = lambda *a, **k: real(*a, **dict(k, refused=None))
rows, trips, was = [], 0, False
try:
t = 0.0
while t < dur:
hass.t = clock[0] = t
for et, fn in list((events or {}).items()):
if et <= t:
fn(c)
del events[et]
await c.read_inputs(now_mono=t)
stale = c.inverters[0].batt_fresh.stale
trips += stale and not was
was = stale
await c.cycle()
rows.append((t, hass.load(t) - hass.batt(), hass.batt(),
hass.cmd, c.i_w, c.loop_reason, c.batt_refused))
t += TICK
finally:
m.compute, m.datetime = real, real_dt
return rows, trips, c
return asyncio.run(go())
def at(rows, t):
return min(rows, key=lambda r: abs(r[0] - t))
def longest_hold_h(rows, floor_w=250.0, until=None):
"""Longest run of one identical request at or above `floor_w`, in hours."""
best = cur = 0.0
last = None
for r in rows:
if until is not None and r[0] >= until:
break
cur = cur + TICK if (r[3] == last and abs(r[3]) >= floor_w) else 0.0
last = r[3]
best = max(best, cur)
return best / H
# ==============================================================================
print("1. the 09-06 shape: a load step takes the request to 5000 W, the battery "
"cuts out, the load ends")
# ==============================================================================
def load906(t):
return 1020 if t < 60 else 4800 if t < 162 else 940 if t < 11.9 * H else -600
def cut906(t):
return t >= 132
def cap906(t):
return 4570.0
old906, otrips906, _ = run(load906, cut906, 12.2 * H, cap906, old=True)
new906, ntrips906, c906 = run(load906, cut906, 12.2 * H, cap906)
for name, rows, tr in (("old", old906, otrips906), ("new", new906, ntrips906)):
print(f" {name}: request at 2 min {at(rows, 120)[3]:+.0f} W, at 6 h "
f"{at(rows, 6 * H)[3]:+.0f} W (i_w {at(rows, 6 * H)[4]:+.0f}), longest "
f"hold {longest_hold_h(rows):.2f} h, gate trips {tr}")
check("PRECONDITION: the old law holds +5000 W for the whole night on this "
"fixture, as it did on 2026-09-06 - the fixture reproduces the card",
at(old906, 6 * H)[3] == 5000.0 and longest_hold_h(old906) > 11.5)
check("the request reaches the rail before the cut, so the new law starts from "
"the same place", at(new906, 120)[3] == 5000.0)
t0 = next((r[0] for r in new906 if r[5] == REFUSED), None)
check(f"after the cut the battery-refuses hold takes the request to 0 W within "
f"about a minute (at t={t0})", t0 is not None and 132 < t0 <= 132 + 90
and at(new906, t0)[3] == 0.0)
check("...and it stays refused overnight, with the integrator at 0, and no "
"request of 250 W or more stands for longer than one probe interval",
at(new906, 6 * H)[6] == 1 and at(new906, 6 * H)[4] == 0.0
and longest_hold_h(new906, until=11.9 * H) < PROBE_EVERY_S / H)
check(f"...and the stale-reading gate does not cycle: {ntrips906} trips in "
f"12 hours (the old law's latch also kept it quiet: {otrips906})",
ntrips906 == 0)
morning = [r for r in new906 if r[0] >= 11.9 * H + 60]
check("when solar makes the grid export, the refusal ends and the battery "
"charges - the exit on the other direction",
morning and morning[-1][6] == 0 and morning[-1][3] < -400)
# ==============================================================================
print("2. the probe: 200 W every 15 minutes, below the gate's 250 W")
# ==============================================================================
probes = []
for r in new906:
if r[3] == PROBE_W and (not probes or r[0] - probes[-1][1] > TICK):
probes.append([r[0], r[0]])
elif r[3] == PROBE_W:
probes[-1][1] = r[0]
starts = [p[0] for p in probes]
gaps = [b - a for a, b in zip(starts, starts[1:])]
print(f" {len(probes)} probes, first at {starts[0] / 60 if starts else 0:.1f} "
f"min, gaps {sorted(set(round(g) for g in gaps))} s, lengths "
f"{sorted(set(round(p[1] - p[0] + TICK) for p in probes))} s")
check("the probe asks exactly PROBE_W, which is below the stale-reading gate's "
"threshold, so a probe can never arm it",
PROBE_W < freshness.MOVE_W and all(r[3] in (0.0, PROBE_W)
for r in new906 if r[6] == 1))
check("there is a probe every 15 minutes through the night (at least 40 in "
"11.8 hours), each about 34 s long",
len(probes) >= 40 and all(PROBE_EVERY_S <= g <= PROBE_EVERY_S + PROBE_S
+ 2 * TICK for g in gaps)
and all(PROBE_S - TICK <= p[1] - p[0] + TICK <= PROBE_S + TICK
for p in probes))
check("...and a probe reads as a probe on the loop's own reason row",
any(r[5] == PROBING for r in new906))
# ==============================================================================
print("3. recovery with no sign change: the battery gives power again at 2 h")
# ==============================================================================
def cut_rec(t):
return 132 <= t < 2 * H
oldr, _, _ = run(load906, cut_rec, 2.6 * H, cap906, old=True)
newr, _, crec = run(load906, cut_rec, 2.6 * H, cap906)
after_o = [r for r in oldr if 2 * H <= r[0] < 2 * H + 600]
after_n = [r for r in newr if 2 * H <= r[0] < 2.6 * H]
exp_o = sum(max(0.0, -r[1]) * TICK for r in after_o) / 3600
exp_n = sum(max(0.0, -r[1]) * TICK for r in after_n) / 3600
print(f" old: worst grid {min(r[1] for r in after_o):+.0f} W, export "
f"{exp_o:.0f} Wh; new: worst grid {min(r[1] for r in after_n):+.0f} W, "
f"export {exp_n:.0f} Wh")
check("PRECONDITION: the old law answers a recovering battery with its "
"standing +5000 W and exports kilowatts into a 940 W house",
min(r[1] for r in after_o) < -3000)
check("the new law never exports more than the probe while it waits, and the "
"answered probe ends the refusal so control resumes",
min(r[1] for r in after_n) > -PROBE_W - 50
and after_n[-1][6] == 0 and abs(after_n[-1][1] - (-10)) < 100)
check("...and the event log says the probe was answered",
any("BATTERY REFUSES ENDED: the probe was answered" in e
for e in crec.events))
# ==============================================================================
print("4. the 09-19 shape: a stale-reading stop on a frozen ~0 W reading "
"is a refusal")
# ==============================================================================
# The request steps +1540 -> +1940 and more as the battery cuts out mid-ramp:
# the request moves after the reading went flat, so the gate trips before the
# hold's 12 cycles - the ~70 s cycle SAFETY-59 measured. The trip seeds the hold.
def load919(t):
return 1530 if t < 60 else 2400 if t < 1800 else 900 if t < 4 * H else -600
def cut919(t):
return t >= 65
def run919(old):
return run(load919, cut919, 4.2 * H, old=old)
old919, otr919, _ = run919(True)
new919, ntr919, c919 = run919(False)
print(f" old: gate trips {otr919}, longest hold {longest_hold_h(old919):.2f} h;"
f" new: gate trips {ntr919}, longest hold {longest_hold_h(new919):.2f} h")
check("PRECONDITION: on the old law the gate trips over and over all night "
"(the SAFETY-59 cycle) or the request stands for hours",
otr919 > 20 or longest_hold_h(old919) > 1.0)
check("the new law stops after at most two trips and holds 0 W, and the event "
"log says the battery refuses",
ntr919 <= 2 and at(new919, 2 * H)[3] in (0.0, PROBE_W)
and any("BATTERY REFUSES" in e for e in c919.events))
# The same shape through `compute()` alone, as the bus saw it on 2026-09-19
# before the gate existed: +1540 -> +1940, then a battery giving nothing.
T = control.Tuning(**LIVE)
res = {}
for name, carry in (("old", None), ("new", 0)):
# sat_count 2: the +1540 and +1940 cycles were already short (the plan)
prev, i_w, sat, ref, cmds = 1940.0, 2340.0, 2, carry, []
for _ in range(2000): # ~2.8 h at 5 s
d = control.compute(prev, 1950.0, CUT_W, T, sat, i_w, refused=ref)
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
cmds.append(prev)
res[name] = cmds
print(f" compute() alone: old stands at {res['old'][-1]:+.0f} W "
f"({sum(v == 1940.0 for v in res['old'])} of 2000 cycles at +1940 W), "
f"new at {res['new'][-1]:+.0f} W from cycle "
f"{res['new'].index(0.0) if 0.0 in res['new'] else None}")
check("PRECONDITION: without the gate the old law parks at +1940 W, the 7 065 "
"identical writes the bus recorded", set(res["old"]) == {1940.0})
check("...and the new law holds 0 W within SETTLE_CYCLES cycles",
res["new"].index(0.0) < control.SETTLE_CYCLES
and set(res["new"][control.SETTLE_CYCLES:]) == {0.0})
# ==============================================================================
print("5. the other exits: stop, start, another writer")
# ==============================================================================
def stop(c):
c.auto = False
def start(c):
c.auto = True
rows, _, c = run(load906, cut906, 1200, cap906, events={600.0: stop,
700.0: start})
check("stopping control ends the refusal, and starting again begins from "
"nothing refused", at(rows, 590)[6] == 1 and at(rows, 650)[6] == 0
and at(rows, 705)[6] == 0)
def other_writer(c):
c.loop_w = 1234.0 # the arbiter gave the wire something the loop did not ask
rows, _, c = run(load906, cut906, 900, cap906, events={600.0: other_writer})
check("another writer on the wire ends the refusal (the arbiter reseed)",
at(rows, 590)[6] == 1 and at(rows, 605)[6] == 0)
# ==============================================================================
print("5b. review of #141: a pack that gives SOME power, and a reading that is "
"only late, are not a refusal")
# ==============================================================================
# A pack derated to 100-499 W (cold, BMS taper) gives what it can against a
# larger ask. Engaging below `saturation_w` (500 W) held it at 0 W for ~93 % of
# the time; "gives nothing" is below the probe's own answer.
# `compute()` alone: through the Controller the stale-reading gate trips on the
# flat 300 W first, and that fixture then passes whatever this threshold is.
def derated(carry, cap_w=300.0, n=1800):
prev, i_w, sat, ref, gave, held = 0.0, 0.0, 0, carry, 0.0, 0
b = 0.0
for _ in range(n): # 2.5 h at 5 s
d = control.compute(prev, 2000.0 - b, b, T, sat, i_w, refused=ref)
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
held += bool(ref)
b = max(0.0, min(prev, cap_w)) # one tick late
gave += b
return gave / n, held
T = control.Tuning(**LIVE)
gave_old, _ = derated(None)
gave_new, held_new = derated(0)
print(f" pack derated to 300 W: old law {gave_old:.0f} W average, new "
f"{gave_new:.0f} W, held as refusing on {held_new} cycles")
check("a pack that gives a steady 300 W against a 2000 W ask is never held at "
"0 W as refusing, and keeps giving what the old law got from it",
held_new == 0 and gave_new == gave_old and gave_old > 290.0)
def lagging(tick, dead_s=6.0, publish_s=10.0, phase_s=5.0, dur=600.0):
"""`compute()` on a HEALTHY pack whose reading lags: it follows the command
of `dead_s` ago, published every `publish_s`. A 1 s meter (`meter_poll_s`
1) makes SETTLE_CYCLES only 12 s, shorter than that lag."""
prev, i_w, sat, ref, hist, reg, pub = 0.0, 0.0, 0, 0, [], 0.0, -phase_s
held = engaged = 0
t = 0.0
while t < dur:
then = [c for tc, c in hist if tc <= t - dead_s]
b = then[-1] if then else 0.0
if t - pub >= publish_s:
reg, pub = b, t
d = control.compute(prev, (3000.0 if t >= 10 else 0.0) - b, reg, T,
sat, i_w, refused=ref)
engaged += bool(d.refused) and not ref
prev, i_w, sat, ref = d.target_w, d.i_w, d.sat_count, d.refused
hist.append((t, prev))
held += tick * bool(ref)
t += tick
return engaged, held
lag1 = lagging(1.0)
print(f" 1 s meter, healthy pack with a late reading: engaged {lag1[0]} "
f"time(s), held {lag1[1]:.0f} s")
check("a healthy pack whose reading is merely late is let go as soon as the "
"reading shows it delivering - not held until the next probe",
lag1[1] <= 10.0)
async def _seed(held_w):
"""`_refusal_from_stale()` on a unit standing at +2000 W, frozen."""
c = Controller(dict(
{"setpoint_entity": "number.sp", "meter_entity": "sensor.grid",
"soc_entity": "sensor.soc", "batt_entity": "sensor.batt",
"meter_source": "off"}, **LIVE),
_Hass(lambda t: 0.0, lambda t: False), _Store(), _Pub(),
stop=asyncio.Event())
c.auto, c.sat_count = True, c.tuning.saturation_cycles
inv = c.inverters[0]
inv.last_write, inv.batt_fresh.held = 2000.0, held_w
c._refusal_from_stale(inv, 100.0)
return c.batt_refused
check("a stale-reading stop on a register standing at 300 W is not a refusal "
"(it gives something), and one at -4 W is",
asyncio.run(_seed(300.0)) == 0 and asyncio.run(_seed(CUT_W)) == 1)
d = control.compute(0.0, 1500.0, 1400.0, T, 0, 0.0, refused=1, probe=False)
check("...i.e. a held direction that reads 100 W or more ends the refusal "
"without waiting for a probe", d.refused == 0)
# ==============================================================================
print("6. words")
# ==============================================================================
w = messages.why(why_key("loop", [Claim.set("loop", 0, 0.0, REFUSED)]), 0.0)
wp = messages.why(why_key("loop", [Claim.set("loop", 0, PROBE_W, PROBING)]),
PROBE_W)
print(f" {w!r} / {wp!r}")
check("the page's Why line says the battery refuses, not 'Keeping the grid "
"near zero: 0 W'", w == "The battery refuses to give power: 0 W")
check("...and a probe says what it is", wp.startswith("Testing if the battery"))
check("...and an ordinary loop cycle still reads as the loop",
why_key("loop", [Claim.set("loop", 0, 10.0, "tracking")]) == "loop")
print()
if fails:
print(f"{len(fails)} FAILED: " + ", ".join(fails))
sys.exit(1)
print("all checks passed")
+97
View File
@@ -0,0 +1,97 @@
#!/usr/bin/env python3
"""SAFETY-52's evidence: the 16-day capture replayed with and without the
battery-refuses hold. `python3 tools/replay_refusal.py`
Same disturbance, fitted plant and pack floor as `replay_recorded_loop.py`,
plus main.py's reseed, 15 s input hold and 0 W rules and the REAL SAFETY-37/57
gate on a register published every 10 s. `old` is `compute()` with
`refused=None`, which is release/1.0's law unchanged; `new` carries the refusal,
runs the probe on main.py's clock and seeds a refusal from a gate trip.
Modelled watt-hours: read the deltas, not the absolutes (see that tool).
"""
import math
import pathlib
import sys
ADDON = pathlib.Path(__file__).resolve().parent.parent
sys.path.insert(0, str(ADDON))
sys.path.insert(0, str(ADDON / "tools"))
import replay_recorded_loop as R # noqa: E402
from app import freshness, control as NEW # noqa: E402
def go(which, rows, fit, publish_s=10.0, stale_input_s=15.0):
law = NEW
tun = law.Tuning(**R.LIVE)
t0, g0, b0, sp0, soc0 = rows[0]
pl = R.Plant(*fit[:4], soc0); pl.seed(t0, b0, sp0)
st = dict(target=sp0, i_w=sp0, sat=0, loop_w=sp0, ref=0, anchor=None)
fr = freshness.Freshness(freshness.BOUNDS["batt"]); reg, reg_t = None, -1e18
bad, trips, was = None, 0, False
M = dict(und=0.0, imp=0.0, exp=0.0, q={}, run=0.0, mx=0.0, last=None, refh=0.0, probes=0)
for i in range(1, len(rows)):
t, gr, ba, sp, soc = rows[i]
dt = t - rows[i - 1][0]
if dt > R.TICK_CAP_S:
pl = R.Plant(*fit[:4], soc); pl.seed(t, ba, sp)
st.update(target=sp, i_w=sp, sat=0, loop_w=sp, ref=0, anchor=None)
fr = freshness.Freshness(freshness.BOUNDS["batt"]); reg_t = -1e18; bad = None
continue
b = pl.step(t, dt, st["target"]); grid = gr + ba - b
if t - reg_t >= publish_s:
reg, reg_t = float(round(b)), t
fr.submit(reg, st["target"], t); batt = fr.reading()
if fr.stale and not was:
trips += 1
if (which == "new" and not st["ref"] and st["sat"] >= tun.saturation_cycles
and abs(reg) < NEW.REFUSED_BELOW_W and abs(st["target"]) > tun.saturation_w):
st["ref"], st["anchor"] = (1 if st["target"] > 0 else -1), t
was = fr.stale
if batt is None:
bad = t if bad is None else bad
if t - bad >= stale_input_s:
st.update(target=0.0, i_w=0.0, loop_w=None)
else:
bad = None
if st["loop_w"] is None or st["target"] != st["loop_w"]:
st["i_w"] = st["target"]
if which == "old":
d = law.compute(st["target"], grid, batt, tun, st["sat"], st["i_w"],
refused=None)
else:
probe = False
if st["ref"] and st["anchor"] is not None:
h = t - st["anchor"]
if h >= NEW.PROBE_EVERY_S + NEW.PROBE_S: st["anchor"] = t
else: probe = h >= NEW.PROBE_EVERY_S
d = law.compute(st["target"], grid, batt, tun, st["sat"], st["i_w"], refused=st["ref"], probe=probe)
if d.refused and not st["ref"]: st["anchor"] = t
if not d.refused: st["anchor"] = None
if probe and d.target_w == NEW.PROBE_W and M["last"] != NEW.PROBE_W: M["probes"] += 1
st["ref"] = d.refused
st.update(sat=d.sat_count, i_w=d.i_w, loop_w=d.target_w, target=d.target_w)
tg = st["target"]
if tg - b > 1000: M["und"] += dt / 3600
if st["ref"]: M["refh"] += dt / 3600
M["imp"] += max(0, grid) * dt / 3.6e6; M["exp"] += max(0, -grid) * dt / 3.6e6
k = math.floor(t / 900); a = M["q"].setdefault(k, [0.0, 0.0]); a[0] += grid * dt; a[1] += dt
M["run"] = M["run"] + dt if (M["last"] == tg and abs(tg) >= 250) else 0.0
M["mx"] = max(M["mx"], M["run"]); M["last"] = tg
worst = max(max(0.0, s / d) for s, d in M["q"].values() if d > 600)
return trips, M, worst
def main():
rows = R.stream()
fit = R.fit_plant(rows, stride=7)
print(f"fit {[round(x, 2) for x in fit]}, {len(rows)} meter instants")
for label, f in (("fitted plant", fit),
("plant offset 0 W", (fit[0], fit[1], fit[2], 0.0, fit[4]))):
for which in ("old", "new"):
tr, M, w = go(which, rows, f)
print(f"{label:17s} {which}: gate trips {tr:4d} | request >1 kW above "
f"delivery {M['und']:6.1f} h | longest held >=250 W "
f"{M['mx'] / 3600:5.2f} h | import {M['imp']:6.1f} kWh export "
f"{M['exp']:5.1f} kWh | worst 15-min {w:5.0f} W | refused "
f"{M['refh']:5.1f} h, probes {M['probes']}", flush=True)