SAFETY-78: maintenance drain at N=2 no longer stalls
At two inverters the drain pins its pack and the site target is split around the pin. Below the pin the other pack had to charge, the allocator refused the opposite directions, and the site sat at 0 W with an ARBITER line every cycle (house below or above the drain rate, or a grid charge). main.py now files a site limit `drain` (lo = what the pin places, at P_MAINTENANCE) at N>=2 while a pack drains, so the other pack only adds power in the same direction. A drain that cannot give power waits with one log line. With battery modes on, no grid charge while a pack drains, and the other battery's card says why. N=1 is byte-identical. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -184,6 +184,12 @@ CLAIM_SCOPE = {
|
||||
# the banner and the claim an install has had since SAFETY-02 shipped.
|
||||
# `Controller.cycle()` does not even arm the site detector there.
|
||||
"sign_site": SCOPE_SITE,
|
||||
# main.py: `Claim.limit("drain", P_MAINTENANCE, lo=...)`, SAFETY-78. At
|
||||
# N>=2, while a pack's maintenance drain is pinned, the site target may
|
||||
# not go below what that pin places: below it a sibling would have to
|
||||
# charge against the drain (circulation, refused, 0 W). A site `lo`,
|
||||
# never filed at N=1. DECISIONS/SAFETY-78-drain-at-two.md.
|
||||
"drain": SCOPE_SITE,
|
||||
|
||||
# --- UNIT: about one pack, one inverter, one device -------------------
|
||||
# main.py: `Claim.limit("device", P_SAFETY, self.dev_min, self.dev_max,
|
||||
|
||||
Reference in New Issue