UX-54 round 3: tomorrow's blocks last as long as control acts, give blocks checked at run start
checks / unit (pull_request) Successful in 48m22s
infra-pin / fresh (pull_request) Successful in 1s

- Tomorrow's grid block is drawn to where control stops charging. A cheap run
  is sized for all batteries together; a slower one is still below
  `charge_to()` when it ends and control plans the next cheap slots. The tab
  asks `modetrade.energy()` and `priceruns.plan()` with the packs at the
  curve's level and extends the run, so the curve charges as long.
- Each battery's block ends where it is at its own level (grid) or at the
  floor (give). The curve puts a point where a battery reaches its charge
  level inside a step.
- `homeview.mode_runs(ahead=f, rp=...)` reads each block at the level the
  curve has when it starts, with Home's own filter and MIN_KWH: no give block
  at the floor, no grid block at the planned level. Home never passes either.
- `no_tomorrow` names the hour from `solarfc.BELL_FROM_H`, where the curve
  stops.
- test_ux54.py part 7 compares control (`_mode_roles()` every 15 minutes) with
  the tab with no tolerance, and adds the cloudy / floor case.

No decision, command, timing or option key changes.

Co-Authored-By: Claude <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Bdqr7PiaHcBnzPituu2yTC
This commit is contained in:
glenn schrooyen
2026-10-27 00:53:58 +01:00
co-authored by Claude
parent 75195f7073
commit 5ab8622265
7 changed files with 258 additions and 89 deletions
@@ -17,13 +17,24 @@ battery's expected level with its blocks. It follows the add-on, as Home does
and draws none when there is no room or energy (`room()` and `plan_need()`
in `homeview.mode_runs()`, the leg sizing in `trade_runs()`). For a day that
has not started that level says nothing, so tomorrow's blocks are built with
`ahead=True` (Home never passes it): a charge is read from the floor, a give
from the ceiling, and a block is drawn wherever the plan and the gate have a
run. A grid block is then dropped where control will not take it: the curve's
level when the run starts is asked of `modetrade.chargers()`, the cycle's own
test. The gate (`mode_gate`, UX-53) is not bypassed. Control, checked every
15 minutes through tomorrow (`test_ux54.py` part 7), gives and charges where
the tab has a block.
`ahead` (Home never passes it): `mode_runs()` reads each block at the level
the curve has when it starts, with its own filter and `MIN_KWH`, so there is
no give block where the battery is at the floor and no grid block where it
is at its planned level. Where the curve has no level yet, a charge is read
from the floor and a give from the ceiling. The blocks and the curve follow
each other and are taken to a fixed point. The gate (`mode_gate`, UX-53) is
not bypassed.
- **A block lasts as long as control acts.** A cheap run is sized for all the
batteries charging together, so a slower one is still below
`modetrade.charge_to()` when it ends, and control plans the next cheap slots
(`Controller._price_runs()`). `dayview._levels()` asks the same functions,
`modetrade.energy()` and `priceruns.plan()`, with the packs at the curve's
level, and draws the grid block to where control stops. Each battery's block
then ends where the curve has it at its own level (the curve puts a point
there), and a give block where it reaches the floor (a step end, within the
0.1 % the tab shows). Control, walked every 15 minutes through tomorrow
(`test_ux54.py` part 7, no tolerance), charges and gives in exactly the
quarters the tab has a block.
- **The sun** is what `solarfc` reads. An hourly split (Solcast
`detailedForecast`, Open-Meteo `wh_period`) is used as given. A daily total
(Forecast.Solar, and any other state-only sensor, the owner's three "today
@@ -60,12 +71,17 @@ is `SolarToday.add()` after the solar read, in a `try`, in memory.
- Prices are planned about a day ahead (`priceruns.HORIZON`), so a block of
tomorrow later than 24 h from now, or one that needs prices not yet
published, appears as the day comes near. The tab says so. Control may also
charge longer than a block when a slower battery is still short at its end.
published, appears as the day comes near. The tab says so.
- Today's blocks are Home's, and are not extended or shortened: control may
plan more once they end, and Home draws it then. The curve stops charging
at its level (`charge_to()`) and giving at the floor.
- Today, a give run in the plan on a battery that is empty now has no block on
Home (no energy to give). The tab equals Home, and says so: "The add-on plans
to give power. No block shows while the battery has no energy to give." The
curve gives in that run if the sun fills the battery first.
- With no forecast for tomorrow the curve stops at the first hour of the sun,
`solarfc.BELL_FROM_H` (06:00): `Forecast.between()` has no answer past it. The
note names that hour from the constant.
- Tomorrow shows price blocks only. A monthly cycle is drawn today, where the
curve then stops for that battery.
- The curve uses the arbitrage floor and ceiling, as the plan does, not the