UX-08 2d review: action log reachable in status JSON, engaged peak row pinned, imported keys expanded
- status_payload() also returns the action log as `events`. The page does not render it. Some entries (a dropped inverter's reason, the peak guard's projection, unplaced watts) are written nowhere else, and DOCS still points installers at the action log. - test_peakguard pins the engaged row's ordered pair (the battery's share, then the limit). - test_messages expands setting keys named by constants imported from another app module, so the shown-text 30-word scan counts them. - p1.py: 'A meter message could not be read'. DOCS glossary: control board in plain words, with the hardware in an installer note. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -52,7 +52,7 @@ The allowlist is empty and its cap is 0 (43 → 0). Every WARNING and ERROR line
|
||||
1. **No code prefixes on log lines.** Nothing outside the repositories greps them, except `/home/homelab/clampwatch.sh`, a one-off site watch from 2026-09-05 that greps `OUTPUT_CLAMP` and `Engagements so far`. `OUTPUT_CLAMP` is still in the reason the line quotes; "Engagements so far" is now "Cut back N times so far". The tests that found a line by its card id (`SAFETY-37`, `SAFETY-44`, `CONTROL LOOP DIED`, `UNGRADED`) now find it by its words.
|
||||
2. **Reason texts keep their codes.** A line quotes a watchdog's reason (`%s`), such as `STALE_READING: …` or `OUTPUT_CLAMP: …`. Those are the evidence an installer searches for and many tests pin them, so they were not rewritten. The line around them is plain.
|
||||
3. **Reasoning moved to DEBUG, not deleted,** for the 10 lines marked DROP-to-DEBUG (for example the 14 768 W history behind the over-rating alarm, why SAFETY-42 reports and does not act, and the Eneco card advice). The 25-word line keeps the action and the numbers. SAFETY-57's promise stays on the ERROR line, as an ordered pair: "until it changes, or 17 s after the command drops below 250 W".
|
||||
4. **The line under the buttons** showed the newest raw action-log entry (`OUTPUT_CLAMP …`, `FAILSAFE …: SIGN_DISAGREEMENT`, `ALLOCATOR …`). Each `log_event()` call now also names a plain hint from `messages.HINTS`, and the page shows that. The action log itself is unchanged, because tests and later analysis read it, and the page no longer shows it.
|
||||
4. **The line under the buttons** showed the newest raw action-log entry (`OUTPUT_CLAMP …`, `FAILSAFE …: SIGN_DISAGREEMENT`, `ALLOCATOR …`). Each `log_event()` call now also names a plain hint from `messages.HINTS`, and the page shows that. The action log itself is unchanged, because tests and later analysis read it, and the page no longer shows it. It stays reachable as `events` in the `status` JSON (review of #136), because some entries are written nowhere else: a dropped inverter's reason, the unplaced watts, the peak guard's projection and the shadow decision.
|
||||
5. **The top table.** *Why* is `messages.why()`: the arbiter's winner and limit in words ("Keeping the grid near zero: 440 W, held back by the peak limit"). `self.reason` keeps `Resolution.explain()` for the log and the checks. *Tariff*, *Price history*, *Arbitrage* and *Shadow mode* keep every figure TARIFF-11 and SAFETY-47 put there, each in its own slot, in words. Labels: *Battery level*, *Solar production*, *Power request*.
|
||||
6. **The month-peak row became two rows**, because one sentence of 15 words cannot hold the peak, its time, its share of the limit and TARIFF-13's coverage figure. The store's state at start (`restore_state`) left the row: it is the INFO line at start.
|
||||
7. **The peak guard rows** name the projection first and the limit second, as before (SAFETY-38). The blind row says what it means for the owner: the battery does not charge until the period can be measured again.
|
||||
|
||||