CFG-01 review: widen the rule, refuse the firmware-veto case, fix the stop footgun

Review findings, all confirmed in code before changing anything.

THE RULE DID NOT AUTHORISE ITS OWN BEST REFUSAL. The stated test was
"makes a safety mechanism inoperative, or makes a stated limit untrue",
and a blank setpoint_entity does neither - layer 1 pinning the inverter
at 0 W is the failsafe WORKING, as validate.py's own text admitted. The
real justification is a second, separate category: the add-on is inert
and indistinguishable from healthy. Stated as (a) and (b), with each
refusal tagged, and with both halves explicitly bounded - (a) is not
"any two numbers that could disagree", (b) is not "anything degraded".
Left implicit, the gap is where trivia-creep comes back in.

meter_max_age_s ABOVE THE FIRMWARE'S VETO IS NOW REFUSED. The schema
allows int(5,300); the firmware's threshold is a compile-time
`max_age_s: "30"` and it trips layer 1 at `p1_age_s >= 30`. At 120 the
add-on believes a 119 s reading is fresh and keeps commanding while the
board has already vetoed and is holding at 0 W - healthy meter, running
controller, nothing moving. Structurally identical to the max_w case,
and unlike max_w it is settable on this install, so the headline
behaviour finally has a live demonstration. That firmware file's own
comment says a lower bound on this "belongs in CFG-01, not here".

Only ABOVE is refused: below the veto the add-on gives up first, which
is fail-safe and visible on its own status page. Scoped to P1 being
enabled, because meter_max_age_s governs nothing otherwise.
FIRMWARE_INGEST_VETO_S cannot be imported from a compile-time YAML
substitution, so it carries a note on the single direction in which it
can go stale - and a warning that TEL-06 is editing `ingest_stale`, so a
matching integer may stop meaning a matching rule.

stop= WAS A LIVE FOOTGUN. It defaulted to None, which made a Controller
that cannot stop itself the DEFAULT one. On the late-refusal path that
meant: log the banner, return, and leave the process alive forever with
no control loop and no exit - the exact "inert but looks healthy"
failure this module exists to refuse. Now required and keyword-only, so
the broken shape does not construct; test_p1.py's five call sites pass
an Event.

That whole path had no test and no live demo. It has one now: it drives
run_control() against a device that only reports a narrower range once
the loop starts, and asserts it refuses, signals, returns, and writes
NOTHING - plus the converse, that an agreeing device leads to real
writes. This also covers the max_w composition that cannot be reached
through the Supervisor on the live install.

max_w <= 0 is refused. Schema-blocked in production, but
validate_startup_config() is the simulation suite's entry point too, and
a non-positive max_w inverts the arbiter's supervised bounds into a
contradiction that reads as a safety trip rather than a typo.

Verified live 2026-08-28 (backup goodwe_controller-cfg01r2-1787940076):
meter_max_age_s 120 refused with a message naming 120, 30, and THE
FIRMWARE WINS; no traceback; add-on restored byte-exact and running.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Du77usMj8XNKNFZGmUiWDa
This commit is contained in:
glenn schrooyen
2026-08-28 20:05:10 +02:00
co-authored by Claude Opus 5
parent fc9bd89dca
commit 547d796c5d
5 changed files with 310 additions and 24 deletions
+15 -5
View File
@@ -57,13 +57,20 @@ def load_options() -> dict:
class Controller:
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub, stop=None):
def __init__(self, opts: dict, hass: HomeAssistant, store, mqtt_pub, *, stop):
self.o = opts
self.hass = hass
self.store = store
self.mqtt = mqtt_pub
# Set by run_control() if the startup gate could not see a conflict
# because the setpoint device had not appeared yet. See run_control().
# ⚠️ REQUIRED, AND KEYWORD-ONLY, AFTER A REVIEW CATCH. This started life
# as `stop=None`, which made a Controller that CANNOT STOP ITSELF the
# default one. On the late-refusal path in run_control() that default
# meant: log the banner, return, and leave the process alive forever
# with no control loop, no exit and no further output - the exact
# "inert but looks healthy" failure this whole module exists to refuse.
# amain() always passed a real Event, so it was latent, but test_p1.py
# was already constructing Controllers without one. No default now, so
# the broken shape does not typecheck.
self.stop_event = stop
self.refused: list[str] | None = None
@@ -325,8 +332,11 @@ class Controller:
refuse(problems)
self.refused = problems
self.log_event("REFUSED: " + problems[0])
if self.stop_event is not None:
self.stop_event.set()
# Signal, then return WITHOUT entering the loop. amain() wakes
# on this, runs the normal wind-down (which commands 0 W) and
# re-raises ConfigRefused afterwards, so the exit code is 78 and
# the inverter is left at zero rather than latched.
self.stop_event.set()
return
last_grid = object()