SAFETY-85: no false 'not keeping up' while maintenance or the peak guard sets the battery
The loop's integrator bound counts only on a cycle the loop decided. A battery another owner set (maintenance, the peak guard, a safety limit) alarms only when it gives more than saturation_w less than told for saturation_cycles cycles. At N>=2 the loop is bounded while maintenance holds a battery, so it does not wind and control comes back one slew step a cycle. The status row counts episodes, not cycles. Digests re-pinned where behaviour changed on purpose; DECISIONS/SAFETY-85-no-false-not-keeping-up.md has the list. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_019DBUfvndgHwaV339Fvd2gr
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
935878193b
commit
4b81387908
@@ -1953,6 +1953,13 @@ over the rating is logged as a software fault, at `ERROR`, and it has its own
|
||||
notification budget.
|
||||
Why: [`DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md`](DECISIONS/SAFETY-40-the-integrator-bound-is-not-a-bug.md).
|
||||
|
||||
The integrator bound counts only on a cycle the loop decided. While
|
||||
maintenance, the peak guard or a safety limit sets a battery, the same alarm
|
||||
fires only when that battery gives more than `saturation_w` less than it was
|
||||
told, for `saturation_cycles` cycles. At two or more inverters the loop does not
|
||||
wind while maintenance holds a battery.
|
||||
Why: [`DECISIONS/SAFETY-85-no-false-not-keeping-up.md`](DECISIONS/SAFETY-85-no-false-not-keeping-up.md).
|
||||
|
||||
### The frozen-meter alarm
|
||||
|
||||
A meter that has died is easy — it stops answering, the sample age climbs past
|
||||
@@ -3122,7 +3129,9 @@ The battery gives less power than the add-on asks for. This is normal for a
|
||||
short time, for example just after a large load switches on or the sun comes
|
||||
out. It is not a fault, and control keeps running. If it keeps coming back,
|
||||
check that the battery is switched on, and that it is not empty (when it should
|
||||
give power) or full (when it should charge).
|
||||
give power) or full (when it should charge). During the monthly maintenance or
|
||||
while the peak limit is guarded, it only shows when the battery gives less than
|
||||
it was told. The status page counts how many times it happened.
|
||||
|
||||
### Power request too high
|
||||
|
||||
@@ -3227,7 +3236,8 @@ section without a link. The documentation tab adds no heading anchors, so the
|
||||
link cannot jump to the section.
|
||||
|
||||
**Battery is not keeping up.** The grid-following loop's integrator reached its
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40). No command went over the
|
||||
anti-windup bound (`integrator_max_w`, SAFETY-40), or a battery that another
|
||||
owner set gave less than it was told (SAFETY-85). No command went over the
|
||||
rating. The log line is a WARNING with reason code `OUTPUT_CLAMP`. See *The
|
||||
winding-loop alarm*.
|
||||
|
||||
|
||||