SAFETY-126: a landing error on the aim is not an overrun
During the night grid charge under the peak reserve the guard alarmed (ERROR PEAK_GUARD_FLOOR_LIMITED, "Battery stopped limiting the peak") and the Batteries "Why" said "The peak limit needs power" at quarter ends, while every quarter landed on the aim. The charge lands the period 0-7 W over the aim and excess_w()'s 900 / remaining turns that into tens of kW in the last second; with nothing able to give, check_peak_floor_limited() alarmed on any wanted > 0. Each cycle the guard wants power, _peak_landing() asks misses_aim(): with the batteries at 0 W, does the period end more than ALARM_MISS_W over the aim? If not, the decision is within_aim: no reserve alarm, no red peak row, no "Why" peak. The claim and the commands are unchanged. A real overrun under the reserve alarms on the same cycle as before. Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
cc9bbeb73e
commit
40595e42ae
@@ -2,6 +2,10 @@
|
||||
|
||||
## 0.19.2
|
||||
|
||||
### Not in a release yet
|
||||
|
||||
- The night grid charge no longer raises "Battery stopped limiting the peak" when the 15-minute period stays on the aim ([[SAFETY-126]]).
|
||||
|
||||
**A patch bump: one fix for charging from the grid under the peak limit, and no option changes.**
|
||||
No option was added, removed or renamed, and no default changed (86 options).
|
||||
**Existing installs need no option change:** options that start 0.19.1 also
|
||||
|
||||