# Changelog # Changelog
## 0.15.0
**A minor bump: changed behaviour, and no option changes.** No option was
added, removed or renamed, and no default changed (83 options). Options that
start 0.14.0 also start 0.15.0. The changes below apply with one inverter and
with two.
The add-on now learns and saves, per battery, what its power reading shows
at rest (`unit/<name>/idle_w`). It learns it after about two quiet minutes and
uses 0 W until then, as before. There is nothing to set.
Contents of this release, in merge order since 0.14.0 (`02ed120`):
| | |
|---|---|
| `cf705a9` | No more false "battery power reading stopped changing" errors at a new command after a rest, or at a change of phase. Each one paused control for a few seconds (several a day on a live site). A healthy battery that lags or turns around is no longer held as refusing for up to 15 min. With two inverters, a refusing battery whose reading at rest is about −100 W is now caught too. The rest value used is limited to ±75 W ([[SAFETY-94]], [[SAFETY-97]], also fixes [[SAFETY-58]]) |
| `3129dae` | CI tests against a newer `admin/goodwe` (CI only) ([[CI-14]]) |
### Known issues
- A false "Battery is not keeping up" can still show when the peak guard pauses a maintenance charge ([[SAFETY-92]]).
- After a gap in the P1 meter, the peak guard is blind for the rest of that quarter hour ([[SAFETY-90]]).
- A battery capped at a low limit with a perfectly flat reading can still trip the stale check ([[SAFETY-74]]).
- A battery whose reading at rest is beyond about ±170 W is still not caught when it refuses, as in 0.14.0 ([[SAFETY-97]]).
- Two inverters: if one battery's drain stops early (e.g. switched Off), the other battery can jump to about 1.6 kW at once, and the surplus goes to the grid ([[SAFETY-95]]).
- Two inverters: after one battery's link drops, control can stall until a safety stop ([[SAFETY-96]]).
- Two inverters: the maintenance charge can switch on and off while the house is above the peak aim ([[SAFETY-88]]).
- Two inverters: the "circulating" figure counts a battery's reading at rest ([[SAFETY-98]]).
### If you are crossing from a version older than 0.10.0
`## 0.10.0` below can refuse an old config: `slew_w` above its limit, and the
withdrawn `price_provider` ids `engie_dynamic`, `totalenergies_dynamic` and
`eneco_eddy`. Read it before you update. Run `tools/predeploy_check.py` with the
bare options (`jq '.data.options'`) first.
## 0.14.0 ## 0.14.0
**A minor bump: new behaviour with two inverters, and no option changes.** **A minor bump: new behaviour with two inverters, and no option changes.**
+1 -1
View File
@@ -1,5 +1,5 @@
name: GoodWe RS485 Controller name: GoodWe RS485 Controller
version: "0.14.0" version: "0.15.0"
slug: goodwe_controller slug: goodwe_controller
description: >- description: >-
Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart Drives a GoodWe ES/BP battery inverter over RS485 by emulating its smart