MAINT-28 fix-forward: the peak pause ends only on a settled house estimate, and a pack under its peak reserve gives nothing for the house while it holds
Rig FAIL (TEST-23, f3f9483). F-1: the hold ended at each guard step because
grid + site_batt_w added a new meter reading to a battery reading up to 10 s
old. It now ends only when no battery reading may pre-date a step up of its
command (Controller._batts_settled()). F-2: while the pause holds, a pack in
maintenance CHARGE at or under its peak reserve is limited to 0 W, so it gives
only what the guard claims for the peak. Sim: Lag.batt_period_s (a held 10 s
register). Tests: test_maint28b.py. DECISIONS updated.
Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude
parent
f3f9483d9c
commit
34b81e8aeb
@@ -1,6 +1,6 @@
|
||||
# MAINT-28 - during a real peak the maintenance charge stays paused
|
||||
|
||||
**Status: for review.** Tests: `test_maint28.py`. No option added; the peak aim, the month peak and the MAINT-13 numbers are unchanged. MAINT-24 follow-up (rig test finding F-1, `reports/MAINT-24-test-report.md`).
|
||||
**Status: fix-forward after the rig FAIL (TEST-23, f3f9483).** Tests: `test_maint28.py`, `test_maint28b.py`. No option added; the peak aim, the month peak and the MAINT-13 numbers are unchanged. MAINT-24 follow-up (rig test finding F-1, `reports/MAINT-24-test-report.md`).
|
||||
|
||||
## What happened (rig x10, house 6.5 kW, month aim 5.95 kW, A in maintenance CHARGE)
|
||||
`peakguard.shaping_suspended()` pauses the charge while the forecast is over the aim or the guard is engaged. MAINT-24 moved the aim from 3450 W to the month aim (SAFETY-80), so the pause no longer lasts the whole peak: the guard gives, its projection drops under 5950 W and it idles ("heading for 5 6xx W, under this month's peak"), the pause ends, the floor charges A 150-460 W, the grid goes to 6.3-6.9 kW, the guard trips again. A flipped charge/give 468 times in 45 min (base 02eac3b 11). The quarters stayed at the aim; the cost was a battery working against itself and a grid that swung 5.4-6.9 kW.
|
||||
@@ -8,7 +8,7 @@
|
||||
## The change
|
||||
`peakguard.shaping_held(suspended, held, forecast, aim, house)`: `suspended` is the old `shaping_suspended()`, and once it was true the pause stays until the house (`grid + battery power`, the load without our own charge) is `MAINT_RESUME_UNDER_W` = 300 W under the aim. A guard that is engaged or a forecast over the aim still pauses at once. House unread: the forecast stands in; neither read: no pause (SAFETY-63). `ctl_cycle.py` keeps the flag in `_maint_peak_hold`. The hold is for N=2 and up, and only where MAINT-24 moved the aim (a banked month peak above `peak_cap_w`, so the aim is above cap minus margin). Elsewhere the old rule stays, byte for byte: SAFETY-87's N=1 digests (`n1_charge_low`) and SAFETY-119's N=2 charge at 5050 W over a 5000 W cap with no banked peak are pinned, and 1b5f7c9 behaves as 02eac3b there (a chase that was not a MAINT-24 regression).
|
||||
|
||||
Why the house and not the forecast: while A gives, the forecast sits just under the aim by design, so no forecast margin is both safe and reachable. The house is the meter reading plus the batteries' power (`grid + site_batt_w`): the net demand the meter would see with no battery at work. Solar is already in it, and that is right: the aim is a limit on what the meter takes, so a sunny hour that lowers the net demand is real room, and a cloud that raises it brings the hold back at once. It is not the gross load, and it would be wrong to add PV back (that would hold the pause on room the meter really has). It stays put when A switches, except for the age of the battery reading (up to 10 s on the rig); the 300 W line is far larger than that lag moves it.
|
||||
Why the house and not the forecast: while A gives, the forecast sits just under the aim by design, so no forecast margin is both safe and reachable. The house is the meter reading plus the batteries' power (`grid + site_batt_w`): the net demand the meter would see with no battery at work. Solar is already in it, and that is right: the aim is a limit on what the meter takes, so a sunny hour that lowers the net demand is real room, and a cloud that raises it brings the hold back at once. It is not the gross load, and it would be wrong to add PV back (that would hold the pause on room the meter really has). It does not stay put when a battery steps: see "Fix-forward" below.
|
||||
|
||||
Why 300 W: the house wanders +-50 W; once the charge resumes it settles at (aim - house) / 2, so 300 W gives at least 150 W, three times the noise, and charging less than that is not worth a restart.
|
||||
|
||||
@@ -34,3 +34,12 @@ Rig (MAINT-24 test report, F-1): 468 reversals in 45 min on 1b5f7c9, 11 on 02eac
|
||||
|
||||
## Not changed
|
||||
MAINT-24's rate and its tests, N=1, the drain, modes off (digests of 1b5f7c9). The pause for a late or missing forecast.
|
||||
|
||||
## Fix-forward (rig FAIL F-1, F-2; `reports/MAINT-28-test-report.md`)
|
||||
The sim had no battery-reading lag, and the first version said the 300 W line is far larger than the lag moves the estimate. That was wrong. The rig publishes a battery's power every 10 s; the meter is newer. After each guard step charge -> give (+500-1000 W) the next meter reading shows the give and the battery reading still shows the charge, so `grid + site_batt_w` drops by the step, under the 5650 W line: 69/69, 132/133, 215/215, 51/51 releases at a median 5430 W with the house at 6450 W or more. Test: `test_maint28b.py`, sim `Lag.batt_period_s`.
|
||||
|
||||
**F-1: the pause ends only on a settled estimate.** `Controller._batts_settled()` is False from a step UP of a unit's command (`MAINT_STEP_W` = 100 W more give or less charge, the SAFETY-128 pending size) until its reading changed `PLANT_SETTLE_S` (6 s) after the step, or `BATT_OBLIGED_S` (17 s) have passed. `peakguard.shaping_held(..., settled)` then keeps the pause. A step down makes the estimate err high, which only holds the pause, so it waits for nothing. Measured in the 45 min sim, pause on: settled, the estimate was at most 146 W under the real house (0 cycles over 300 W); not settled, up to 1933 W under (725 of 1611 cycles over 300 W). Sim, 45 min, house 6500 W: 83 of 83 releases on a stale estimate (f3f9483) -> 0; flips 148 -> 1 (1b5f7c9 210). Charge is back 13 s after the load (7 s in the test), not 0: the first settled estimate. No cut-back is touched.
|
||||
|
||||
**F-2: under its peak reserve the pack gives nothing for the house.** While the pause holds (N>=2, month aim above the cap), a pack in maintenance CHARGE that `peakguard.reserve_split()` holds gets `hi` = 0 W (P_MAINT_SHAPE). The guard's own claim for the peak is on the other packs (`place_on_able()`), so it is unchanged. Above the reserve nothing changes. Sim, B charging at 18 %: f3f9483 gave 1.89 kWh and went to 10.0 % (the log said "giving nothing for the peak"); now 0.00 kWh, 18.2 %, 0 give/idle flips in 45 min (the full cap measured by the reviewer: 32 in 40 min), quarters 5948 and 5952 W (aim 5950).
|
||||
|
||||
Mutants, each red in `test_maint28b.py`: the freshness check dropped (always settled); the reserve claim dropped.
|
||||
|
||||