DOC-1: operator docs name the real P1 entity and a roster that starts
checks / unit (pull_request) Successful in 8m8s
checks / unit (pull_request) Successful in 8m8s
- DOCS.md / config.yaml: the watchdog's P1 age entity is sensor.goodwe_p1_sample_age (device "GoodWe" + "P1 sample age", as app/mqtt.py announces and the live install recorded), not sensor.p1_sample_age_s. - DOCS.md: the inverters: example and per-entry table carry the required bms_soc_floor (and capacity_kwh); config.yaml's schema comment says four required keys, not three. - Field guide: marked v0.1.0/outdated; slew_w row no longer recommends the 1000 W that SAFETY-39 now refuses. HTML regenerated; the PDF is NOT rebuilt (no Chrome here). README/DOCS pointers fixed. - test_docs.py: the documented roster must pass app/validate.py and the schema's per-entry keys; the documented entity id must equal the id composed from app/mqtt.py; the wrong id may appear in no shipped doc. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01BwRLw7eKYj2byVdwB6kbjU
This commit is contained in:
@@ -93,7 +93,7 @@ options:
|
||||
# against a sibling's numbers; an entry silently inheriting `soc_entity` would
|
||||
# rebuild that defect in YAML. `name`, `setpoint_entity`, `max_w` and
|
||||
# `bms_soc_floor` are therefore REQUIRED of every entry (the schema below enforces it, and
|
||||
# validate.py rule 9 enforces it again for the callers the Supervisor never
|
||||
# validate.py rules 8 and 9 enforce it again for the callers the Supervisor never
|
||||
# sees). An omitted `soc_entity`/`batt_entity` means THIS UNIT HAS NO SUCH
|
||||
# SENSOR - `inputs_ok` already stops the site for that - and never means
|
||||
# "use the other one's".
|
||||
@@ -224,7 +224,7 @@ options:
|
||||
# ha_signed reads ONE signed HA entity (+ import / - export), which is what a
|
||||
# HomeWizard P1 publishes and what ha_dsmr cannot consume.
|
||||
# homewizard_local skips Home Assistant entirely and polls the meter's own
|
||||
# local API. ⚠️ It is the ONLY mode whose sensor.p1_sample_age_s measures when
|
||||
# local API. ⚠️ It is the ONLY mode whose sensor.goodwe_p1_sample_age measures when
|
||||
# the meter REPORTED rather than when the value last CHANGED - HA emits
|
||||
# nothing at all for a repeated reading - so it is the only mode a firmware
|
||||
# watchdog may threshold. See DOCS.md.
|
||||
@@ -916,12 +916,13 @@ schema:
|
||||
# batteries, whereas an absent capacity has an honest answer - no opinion
|
||||
# about the split, every unit weighs 1.0, which is what shipped.
|
||||
#
|
||||
# ⚠️ THREE KEYS ARE REQUIRED PER ENTRY AND THAT IS DELIBERATE. An entry with
|
||||
# ⚠️ FOUR KEYS ARE REQUIRED PER ENTRY AND THAT IS DELIBERATE. An entry with
|
||||
# no `name` has no Store namespace and would share another unit's SAFETY-02
|
||||
# latch; one with no `setpoint_entity` is a unit nothing can command; one with
|
||||
# no `max_w` would have to borrow a rating, which is the sibling-grading
|
||||
# defect DEV-02 removed. The optional pair is the sensors, whose absence
|
||||
# honestly means "this unit reports none".
|
||||
# defect DEV-02 removed; `bms_soc_floor` is SAFETY-32's (options block above).
|
||||
# The optional keys are the sensors, whose absence honestly means "this unit
|
||||
# reports none", and `capacity_kwh`.
|
||||
#
|
||||
# ⚠️ THIS BLOCK IS DECLARED BEFORE `max_w:` ON PURPOSE. `max_w` now appears
|
||||
# TWICE under `schema:` - once nested here, once flat below - and a reader
|
||||
|
||||
Reference in New Issue