MAINT-28: shorter test_maint28 runs (892 s -> ~280 s), digests re-pinned on 1b5f7c9; hold kept through the two short holds (documented); DECISIONS duplicate removed
checks / unit (pull_request) Successful in 40m7s
infra-pin / fresh (pull_request) Successful in 2s

Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-11-13 02:29:27 +01:00
co-authored by Claude
parent f5bd2a3520
commit 29a8a05f30
3 changed files with 24 additions and 20 deletions
@@ -12,12 +12,12 @@ Why the house and not the forecast: while A gives, the forecast sits just under
Why 300 W: the house wanders +-50 W; once the charge resumes it settles at (aim - house) / 2, so 300 W gives at least 150 W, three times the noise, and charging less than that is not worth a restart.
The flag lives only while the charge-only branch is taken: every cycle starts it at False, so a maintenance that ended, a mode change or a missing aim cannot carry a stale True into the next charge (test_maint28.py part 1b). The hold is for N=2 and up, and only where MAINT-24 moved the aim (a banked month peak above `peak_cap_w`, so the aim is above cap minus margin). Elsewhere the old rule stays, byte for byte: SAFETY-87's N=1 digests (`n1_charge_low`) and SAFETY-119's N=2 charge at 5050 W over a 5000 W cap with no banked peak are pinned, and 1b5f7c9 behaves as 02eac3b there (a chase that was not a MAINT-24 regression).
The flag lives only while the charge-only branch is taken: every cycle that reaches the maintenance loop starts it at False, so a maintenance that ended, a mode change or a missing aim cannot carry a stale True into the next charge (test_maint28.py part 1b). `cycle()` has two returns before that loop, and the flag is kept through them on purpose: "inputs missing" and "readings late" (SAFETY-128) are holds of under `stale_after` seconds that write nothing and decide nothing, so the next full cycle sees the same charge and the same peak. A missed poll must not end a peak pause; a reset there would restart the charge on it (`_maint_shape_suspended` is kept through them the same way).
It only ever keeps the maintenance charge off. No cut-back is delayed or weakened: the guard's claim is filed as before. While the pause is held the loop works as at 02eac3b, so A also gives for the house (quarters then sit under the aim, A's energy goes to the load: 1.67 kWh in the 45 min below, 0.45 kWh on 1b5f7c9). A cap on that give would conflict with the guard's `lo` (`lo > hi` resolves to 0 W), so it is not tried here.
## Numbers (sim, real `cycle()`, A rated 2500 W)
House 3000 -> 6500 W for 45 min -> 3000 W, +-50 W every 5 s, banked month peak 6000 W (aim 5950 W), forecast = quarter average so far plus the rest at the present grid (`scratch/MAINT-28/dev/m28_repro.py`; `test_maint28.py` runs the same shape for 20 min to keep the suite short).
House 3000 -> 6500 W for 45 min -> 3000 W, +-50 W every 5 s, banked month peak 6000 W (aim 5950 W), forecast = quarter average so far plus the rest at the present grid (`scratch/MAINT-28/dev/m28_repro.py`; `test_maint28.py` runs the same shape for 15 min to keep the suite short).
| 45 min load | base 02eac3b | 1b5f7c9 | MAINT-28 |
|---|---|---|---|
@@ -33,4 +33,4 @@ Rig (MAINT-24 test report, F-1): 468 reversals in 45 min on 1b5f7c9, 11 on 02eac
`test_maint28.py`: part 1 the real peak, 1b the stale hold, 2 `shaping_held()` edges, 3 the unchanged cases (digests equal 1b5f7c9). On 1b5f7c9 itself (hold stubbed out) part 1 and 1b fail. Mutants, each red: M1 hold state not kept (`held` always False: the 1b5f7c9 behaviour); M2 resume line `-` to `+`; M3 house not passed; M4 the per-cycle reset removed; M5 the N=1 gate removed (digest `n1_peak`: N=1, banked peak, house 6500 W); M6 the aim gate removed (digest `n2_nobank`).
## Not changed
MAINT-24's rate and its tests, N=1, the drain, modes off (digests of 02eac3b). The pause for a late or missing forecast.
MAINT-24's rate and its tests, N=1, the drain, modes off (digests of 1b5f7c9). The pause for a late or missing forecast.