EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
Solar charges the car from the signed spare sun (car + battery charge - grid import), less the batteries' room (Batteries first) and the sun kept back, whole amps rounded down, at most one change per 30 s and only on 1 A. It starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A. Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min down, one switch per 10 min). What the peak guard would ask the batteries for is taken off the car first, at once. Every way out of Solar ends at 0 A, written once; at shutdown before the inverters go to 0 W. - app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write site, its sequence and watch); spare_w, car_target_w, amps_for. - app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order. - Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh, three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG. - test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks that pinned "Solar is refused" / "three entities" updated. Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,54 @@
|
||||
# EV-05 — Solar mode: spare sun to the car
|
||||
|
||||
The design is `reports/EV-01-design-report.md` (sections 2 to 5, decisions 2 and
|
||||
5) and the EV-05 brief v3 (owner answers Q1 and Q4, 2026-11-17). This record
|
||||
keeps what the code had to decide.
|
||||
|
||||
## Where it lives
|
||||
|
||||
`carmode.SolarPlan` decides (pure, monotonic clock): what current, on what
|
||||
phases. `carmode.SolarWriter` makes the charger match it. It is a subclass of
|
||||
`ManualWriter`, so the write, the read-back, the phase sequence and the
|
||||
other-writer watch are Manual's and there is still one `write_current` and one
|
||||
`write_phases` call in `app/` (test_ev04.py's AST check). `ctl_car` builds the
|
||||
inputs (`car_sun_inputs`) and runs the writer in the same background task.
|
||||
|
||||
## The rules the brief left open
|
||||
|
||||
- **Entering Solar starts at 0 A.** Choosing Solar, a restart in Solar, the
|
||||
charger or Home Assistant coming back, a charger error or a stuck reading
|
||||
clearing, and control starting again all reset the plan: 0 A if the charger
|
||||
shows more, then the start rule. Switching from Manual to Solar therefore
|
||||
pauses a Manual charge for the start dwell. Simple and on the safe side.
|
||||
- **The peak cut is what the guard would ask the batteries for.** The excess is
|
||||
taken off the car only when the guard is engaged and wants a discharge
|
||||
(`wanted_w > 0`), and by `min(excess, wanted)`. Batteries that only stop
|
||||
charging in a cloud's first seconds are not "asked", so a cloud does not cut
|
||||
the car. A partial cut caps the car for the rest of that 15-minute period.
|
||||
- **The 4.0 to 4.14 kW band on 3 phases.** 3 phases need 4.14 kW at 6 A, the
|
||||
switch back to 1 phase is under 4.0 kW. Inside that band the car holds 6 A on
|
||||
3 phases with no pause count (the hysteresis the design chose). Under 4.0 kW
|
||||
the down-switch comes after 5 minutes; if the 10-minute gap blocks it, the
|
||||
pause rule does instead.
|
||||
- **A phase switch also waits for the 30 s write rule**, so the current set
|
||||
after a switch is never sooner than 30 s after the one before it.
|
||||
- **The meter's age.** The spare is not computed from a meter reading older
|
||||
than `stale_input_s`, also when `meter_max_age_s` (P1) is longer.
|
||||
- **A stale, stuck or not corroborated charging car makes the spare unknown**:
|
||||
hold, then 0 A after *Pause after*. A paused or idle car with a fresh reading
|
||||
counts 0 W (`car_w_trusted` is None outside mode3 C).
|
||||
- **A stuck reading's 0 A is written whatever the frozen read-back says**, since
|
||||
that read-back means nothing then. Every other exit skips the write when the
|
||||
charger already shows 0 A, and never writes over another writer.
|
||||
- **The guard's alarm path** uses the Solar car like Manual's
|
||||
(`car_alarm_w`), and Solar's own 0 A (pause, cut, phase change) gets EV-15's
|
||||
bounded grace (`_car_solar_pause`). A Solar quarter is never banked as "set
|
||||
by the car", and Solar shows no *Car over the peak limit*.
|
||||
- **Shadow mode** runs the plan without writing, so the card says what it would
|
||||
set; the charger got its one 0 A when shadow mode came on.
|
||||
|
||||
## Solar kWh
|
||||
|
||||
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,
|
||||
`min(car power, max(0, spare))` Car first; never above today's kWh; reset at the
|
||||
day change; kept in the store (`car_sun`).
|
||||
Reference in New Issue