EV-05: car Solar mode (spare sun to the car, Batteries or Car first, cut first for the peak)
checks / unit (pull_request) Failing after 24m58s
infra-pin / fresh (pull_request) Successful in 1s

Solar charges the car from the signed spare sun (car + battery charge - grid
import), less the batteries' room (Batteries first) and the sun kept back,
whole amps rounded down, at most one change per 30 s and only on 1 A. It
starts after ev_start_min of enough sun, holds 6 A for ev_pause_min, then 0 A.
Auto phases through EV-04's safe sequence (4.5 kW / 3 min up, 4.0 kW / 5 min
down, one switch per 10 min). What the peak guard would ask the batteries for
is taken off the car first, at once. Every way out of Solar ends at 0 A,
written once; at shutdown before the inverters go to 0 W.

- app/carmode.py: SolarPlan (pure) and SolarWriter (ManualWriter's one write
  site, its sequence and watch); spare_w, car_target_w, amps_for.
- app/ctl_car.py: Solar inputs, the cut, the solar kWh, EV-15's grace for
  Solar's own 0 A, no "set by the car" for Solar; main.py: shutdown order.
- Home card, HA select.goodwe_car_sun_first, sensor car_today_solar_kwh,
  three options with defaults, strings EN/NL, DOCS, DECISIONS, CHANGELOG.
- test_ev05.py, test_ev05_long.py, tools/ev05_sun.py; test_ev03/ev04 checks
  that pinned "Solar is refused" / "three entities" updated.

Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
ems-agent
2026-11-17 23:54:06 +01:00
co-authored by Claude
parent 9fdce023e9
commit 29480fda47
28 changed files with 3410 additions and 103 deletions
@@ -0,0 +1,54 @@
# EV-05 — Solar mode: spare sun to the car
The design is `reports/EV-01-design-report.md` (sections 2 to 5, decisions 2 and
5) and the EV-05 brief v3 (owner answers Q1 and Q4, 2026-11-17). This record
keeps what the code had to decide.
## Where it lives
`carmode.SolarPlan` decides (pure, monotonic clock): what current, on what
phases. `carmode.SolarWriter` makes the charger match it. It is a subclass of
`ManualWriter`, so the write, the read-back, the phase sequence and the
other-writer watch are Manual's and there is still one `write_current` and one
`write_phases` call in `app/` (test_ev04.py's AST check). `ctl_car` builds the
inputs (`car_sun_inputs`) and runs the writer in the same background task.
## The rules the brief left open
- **Entering Solar starts at 0 A.** Choosing Solar, a restart in Solar, the
charger or Home Assistant coming back, a charger error or a stuck reading
clearing, and control starting again all reset the plan: 0 A if the charger
shows more, then the start rule. Switching from Manual to Solar therefore
pauses a Manual charge for the start dwell. Simple and on the safe side.
- **The peak cut is what the guard would ask the batteries for.** The excess is
taken off the car only when the guard is engaged and wants a discharge
(`wanted_w > 0`), and by `min(excess, wanted)`. Batteries that only stop
charging in a cloud's first seconds are not "asked", so a cloud does not cut
the car. A partial cut caps the car for the rest of that 15-minute period.
- **The 4.0 to 4.14 kW band on 3 phases.** 3 phases need 4.14 kW at 6 A, the
switch back to 1 phase is under 4.0 kW. Inside that band the car holds 6 A on
3 phases with no pause count (the hysteresis the design chose). Under 4.0 kW
the down-switch comes after 5 minutes; if the 10-minute gap blocks it, the
pause rule does instead.
- **A phase switch also waits for the 30 s write rule**, so the current set
after a switch is never sooner than 30 s after the one before it.
- **The meter's age.** The spare is not computed from a meter reading older
than `stale_input_s`, also when `meter_max_age_s` (P1) is longer.
- **A stale, stuck or not corroborated charging car makes the spare unknown**:
hold, then 0 A after *Pause after*. A paused or idle car with a fresh reading
counts 0 W (`car_w_trusted` is None outside mode3 C).
- **A stuck reading's 0 A is written whatever the frozen read-back says**, since
that read-back means nothing then. Every other exit skips the write when the
charger already shows 0 A, and never writes over another writer.
- **The guard's alarm path** uses the Solar car like Manual's
(`car_alarm_w`), and Solar's own 0 A (pause, cut, phase change) gets EV-15's
bounded grace (`_car_solar_pause`). A Solar quarter is never banked as "set
by the car", and Solar shows no *Car over the peak limit*.
- **Shadow mode** runs the plan without writing, so the card says what it would
set; the charger got its one 0 A when shadow mode came on.
## Solar kWh
Per cycle in Solar: `min(car power, max(0, spare - room))` Batteries first,
`min(car power, max(0, spare))` Car first; never above today's kWh; reset at the
day change; kept in the store (`car_sun`).