MAINT-13: a full pack that stops at 98-99 % is not a failed charge
checks / unit (pull_request) Successful in 34m21s
infra-pin / fresh (pull_request) Successful in 1s

A charge is complete at SoC >= target, or at >= target - 3 once the SoC has
made no new high for 60 min of allowed charging, or when the charging time
runs out at >= target - 3. The 36 h timeout counts only the minutes the price
gate let the pack charge (plus a 7 day wall-clock backstop). A cycle that
fails (stuck drain, charge below target - 3) backs off 7 days, tells the
operator once (EN + NL), and no cycle starts on that pack in that time unless
the operator forces one. State survives a restart; old state files load.

No option added. DECISIONS/MAINT-13-full-pack-is-complete.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
glenn schrooyen
2026-10-08 09:36:06 +02:00
co-authored by Claude Opus 5.5
parent b527e99f13
commit 28eff568b5
9 changed files with 776 additions and 16 deletions
+119 -7
View File
@@ -65,10 +65,26 @@ POWER_MOVING = (DRAIN, CHARGE, HOLD)
# 12 h means the battery is not following commands - a fault, not a slow day. The charge phase deliberately waits for sun and for cheap hours, so
# it is expected to span a night; 36 h still bounds it.
DRAIN_TIMEOUT_MIN = 720
# MAINT-13: minutes the pack was ALLOWED to charge (the price gate open), not
# wall-clock minutes since the charge began. See CHARGE_WALL_TIMEOUT_MIN.
CHARGE_TIMEOUT_MIN = 2160
# After an abort, do not immediately re-trigger in the same start hour.
RESTART_COOLDOWN_MIN = 90
# MAINT-13 (DECISIONS/MAINT-13-full-pack-is-complete.md). Constants, not options.
# A pack that reaches target - 3 and then takes no more charge for this many
# minutes of allowed charging counts as full.
CHARGE_NEAR_FULL_PCT = 3
CHARGE_STALL_MIN = 60
# Wall-clock backstop for a charge whose gate never opens (no cheap hours, no sun).
CHARGE_WALL_TIMEOUT_MIN = 10080
# A failed cycle (stuck drain or charge) is not retried before this many days.
FAIL_BACKOFF_DAYS = 7
# One tick counts at most this many minutes: a gap means the add-on was down.
CHARGE_TICK_MAX_MIN = 5
# The charge accounting is written to the state file at most this often.
CHARGE_SAVE_MIN = 5
# ⚠️ CFG-03. THE ONE IN-CODE MIRROR OF config.yaml FOR EVERY `maintenance_*`
# OPTION, and the only place in the add-on where one of these numbers is typed.
#
@@ -257,6 +273,9 @@ class MaintResult:
# showing an idle machine and a due date in the past. Empty on every path
# that is not deferring, so a roster of one never sees it.
deferred: str = ""
# MAINT-13: "drain" or "charge" on the one tick where a cycle FAILED, so
# the Controller can tell the operator once. Empty on every other tick.
failed: str = ""
class UnitHistory:
@@ -344,6 +363,10 @@ class Maintenance:
# per cycle would flush the very context that explains it. Same pattern
# as `Controller._arb_action` and `_maint_shape_suspended`.
self._deferred = ""
# MAINT-13: the charge accounting (see _charge_account), in memory and
# written to the state file every CHARGE_SAVE_MIN minutes.
self._trk = None
self._trk_saved = None
# -- state ---------------------------------------------------------------
@property
@@ -351,6 +374,9 @@ class Maintenance:
return self.store.get("phase", IDLE)
def _enter(self, phase: str, now: datetime, events: list, msg: str) -> None:
self._trk = None
if self.store.get("charge_track") is not None:
self.store.set("charge_track", None)
self.store.set("phase", phase)
self.store.set_time("phase_started", now)
_LOG.info("%s", msg)
@@ -391,6 +417,21 @@ class Maintenance:
return (last_try is None
or (now - last_try) >= timedelta(minutes=RESTART_COOLDOWN_MIN))
def backoff_until(self, now: datetime):
"""MAINT-13: when a failed cycle may be tried again, or None.
None when nothing failed, when the back-off is over, or when a cycle
completed after the failure (a forced start that worked ends it).
"""
failed = self.store.get_time("last_failed")
if failed is None:
return None
done = self.store.get_time("last_completed")
if done is not None and done >= failed:
return None
until = failed + timedelta(days=FAIL_BACKOFF_DAYS)
return until if now < until else None
def wants_start(self, now: datetime) -> bool:
"""Would this pack begin a cycle on this tick if the site let it?
@@ -402,7 +443,8 @@ class Maintenance:
return (self.phase == IDLE and self.cfg.enabled
and in_start_slot(now, self.cfg.start_hour, self.tz)
and self.due(now)
and self._cooled(now))
and self._cooled(now)
and self.backoff_until(now) is None)
# -- operations ----------------------------------------------------------
def force_start(self, now: datetime, blocked_by: str = "") -> list:
@@ -430,6 +472,55 @@ class Maintenance:
self._enter(DRAIN, now, events, "maintenance: forced start -> drain")
return events
def _charge_account(self, now: datetime, soc: float, gate_open: bool) -> dict:
"""MAINT-13: what this charge has used so far, as minutes of ALLOWED time.
`open_min` counts only ticks with the price gate open; `flat_min` counts
gate-open minutes since the SoC last beat its best; a closed gate pauses
both. One tick adds at most CHARGE_TICK_MAX_MIN, so a gap (add-on down)
counts for nothing. A state file from before MAINT-13, or from another
charge, starts from the wall-clock minutes so far: the old behaviour.
"""
since = self.store.get("phase_started")
trk = self._trk
if trk is None:
raw = self.store.get("charge_track")
if isinstance(raw, dict) and raw.get("since") == since:
trk = dict(raw)
else:
trk = {"since": since, "open_min": self._elapsed_min(now),
"flat_min": 0.0, "best": float(soc), "at": None}
self._trk = trk
at = trk.get("at")
try:
last = datetime.fromisoformat(at) if at else None
except (TypeError, ValueError):
last = None
dt = 0.0 if last is None else min(
CHARGE_TICK_MAX_MIN, max(0.0, (now - last).total_seconds() / 60.0))
trk["at"] = now.isoformat()
if soc > trk["best"]:
trk["best"], trk["flat_min"] = float(soc), 0.0
elif gate_open:
trk["flat_min"] += dt
if gate_open:
trk["open_min"] += dt
saved = self._trk_saved
if saved is None or (now - saved).total_seconds() >= CHARGE_SAVE_MIN * 60:
self.store.set("charge_track", dict(trk))
self._trk_saved = now
return trk
def _fail(self, now: datetime, kind: str, why: str) -> MaintResult:
"""MAINT-13: stand down, remember the failure, and tell the Controller."""
events = self.abort(now, why)
self.store.set_time("last_failed", now)
msg = (f"maintenance: the cycle did not finish. It waits "
f"{FAIL_BACKOFF_DAYS} days before it tries again.")
_LOG.warning("%s", msg)
events.append(msg)
return MaintResult(IDLE, True, 0.0, False, events, failed=kind)
def abort(self, now: datetime, why: str) -> list:
events = []
self._enter(IDLE, now, events, f"maintenance: ABORT ({why})")
@@ -457,13 +548,16 @@ class Maintenance:
# -- the machine ---------------------------------------------------------
def tick(self, now: datetime, soc: float | None,
blocked_by: str = "") -> MaintResult:
blocked_by: str = "", gate_open: bool = True) -> MaintResult:
"""One cycle of this pack's state machine.
`blocked_by` is `arbitrate()`'s answer for THIS pack: empty when the
site's one maintenance slot is available to it, otherwise the reason it
is not. It gates two things and nothing else - a start, and a phase that
is already moving power on a pack that does not hold the slot.
`gate_open` (MAINT-13) is whether the pack may charge now (the price
gate); only those minutes count towards the charge timeout.
"""
events: list = []
phase = self.phase
@@ -531,8 +625,8 @@ class Maintenance:
f"after {elapsed:.0f} min -> charge")
return MaintResult(CHARGE, False, None, True, events)
if elapsed > DRAIN_TIMEOUT_MIN:
events += self.abort(now, f"drain stuck at {soc:.0f} % after {elapsed:.0f} min")
return MaintResult(IDLE, True, 0.0, False, events)
return self._fail(now, "drain", f"drain stuck at {soc:.0f} % "
f"after {elapsed:.0f} min")
return MaintResult(DRAIN, True, self.cfg.discharge_w, False, events)
if phase == CHARGE:
@@ -541,9 +635,27 @@ class Maintenance:
f"maintenance: charge complete at {soc:.0f} % after "
f"{elapsed:.0f} min -> holding {self.cfg.hold_min} min to balance")
return MaintResult(HOLD, True, 0.0, False, events)
if elapsed > CHARGE_TIMEOUT_MIN:
events += self.abort(now, f"charge stuck at {soc:.0f} % after {elapsed:.0f} min")
return MaintResult(IDLE, True, 0.0, False, events)
trk = self._charge_account(now, soc, gate_open)
near = soc >= self.cfg.soc_target - CHARGE_NEAR_FULL_PCT
# MAINT-13 rule 1: close to full and no longer taking charge.
if near and trk["flat_min"] >= CHARGE_STALL_MIN:
self._enter(HOLD, now, events,
f"maintenance: the battery takes no more charge at "
f"{soc:.0f} %, so the charge counts as done -> holding "
f"{self.cfg.hold_min} min to balance")
return MaintResult(HOLD, True, 0.0, False, events)
if (trk["open_min"] > CHARGE_TIMEOUT_MIN
or elapsed > CHARGE_WALL_TIMEOUT_MIN):
# MAINT-13 rule 2: out of time close to full is complete.
if near:
self._enter(HOLD, now, events,
f"maintenance: charge time is up at {soc:.0f} %, "
f"close enough to full, so the charge counts as "
f"done -> holding {self.cfg.hold_min} min to balance")
return MaintResult(HOLD, True, 0.0, False, events)
return self._fail(now, "charge",
f"charge stuck at {soc:.0f} % after "
f"{trk['open_min']:.0f} min of charging time")
return MaintResult(CHARGE, False, None, True, events)
if phase == HOLD: