UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified as data or as a built text, and every built text is produced by the real code and checked. This is the gap the 2d scan had: it counted `%s` as one word, so reasons built by loop_clamp_note() and friends were never seen. - Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept): OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak guard (codes now PEAK_GUARD*), the migration report, price feed, price history and gate reasons. Plurals via messages.times()/count(). - Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff "one every 15 minutes or every hour", "not final yet" dropped. - Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO, aiohttp access log only at log level debug, settings warnings once per start, one plain line per Home Assistant outage (hass.Outage). - INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE", "NOT_OBSERVED", "did NOT land", "AND". - Display bugs: WHY_WINNER covers every winner and safety reason (main.why_key(), part 7 finds them in the code); the meter row is amber "waiting for the first reading" inside its limit after a start; the missing-reading age is counted when the page asks. - STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section). No change to safety behaviour, alarm levels, notification ids, triggers, cadence or the banner cascade. One row colour changes (meter at start), justified in DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
125b0702a2
commit
23a3a3f5b5
@@ -424,15 +424,17 @@ class FreezeWatchdog:
|
||||
# page was telling, printed into the log and the HA notification where
|
||||
# it would outlive the page.
|
||||
ceiling = rail_ceiling_w(max_w, dev_min=dev_min, dev_max=dev_max)
|
||||
# UX-10: plain sentences, every figure kept (test_messages.py part 6).
|
||||
capped = ("" if ceiling >= abs(float(max_w))
|
||||
else f", capped from max_w {float(max_w):.0f} W by the "
|
||||
f"setpoint device's own rating")
|
||||
f"inverter's own rating")
|
||||
self.reason = (
|
||||
f"METER_FROZEN: the meter has answered {float(unchanged_s):.0f} s "
|
||||
f"without its measurement changing while the command stands at "
|
||||
f"{float(commanded_w):+.0f} W, at the {ceiling:.0f} W rail{capped} "
|
||||
f"(limits: unchanged over {self.cfg.hold_s:.0f} s, command over "
|
||||
f"{rail_w(max_w, dev_min=dev_min, dev_max=dev_max):.0f} W)")
|
||||
f"METER_FROZEN: the meter has not changed for "
|
||||
f"{float(unchanged_s):.0f} s while the command is "
|
||||
f"{float(commanded_w):+.0f} W, at the {ceiling:.0f} W limit"
|
||||
f"{capped}. Limits: unchanged over {self.cfg.hold_s:.0f} s, "
|
||||
f"command over "
|
||||
f"{rail_w(max_w, dev_min=dev_min, dev_max=dev_max):.0f} W")
|
||||
if self.active:
|
||||
return False
|
||||
self.active = True
|
||||
|
||||
Reference in New Issue