UX-10: the last plain-language leftovers: log lines, two table rows, 'Why: Other', red at 0 s
- test_messages.py part 6: every dynamic part of a WARNING+ line is classified as data or as a built text, and every built text is produced by the real code and checked. This is the gap the 2d scan had: it counted `%s` as one word, so reasons built by loop_clamp_note() and friends were never seen. - Quoted reasons rewritten to STYLE.md (red-alarm shape, codes kept): OUTPUT_CLAMP, METER_FROZEN, CIRCULATING_POWER, STALE_READING, the peak guard (codes now PEAK_GUARD*), the migration report, price feed, price history and gate reasons. Plurals via messages.times()/count(). - Top table: Price history "96 prices over 24 hours for 26 Sep", Tariff "one every 15 minutes or every hour", "not final yet" dropped. - Levels and noise: per-cycle shadow line DEBUG, shadow on/off INFO, aiohttp access log only at log level debug, settings warnings once per start, one plain line per Home Assistant outage (hass.Outage). - INFO jargon and error texts: no "§8.3", ISO times, "banked", "keys ARE", "NOT_OBSERVED", "did NOT land", "AND". - Display bugs: WHY_WINNER covers every winner and safety reason (main.why_key(), part 7 finds them in the code); the meter row is amber "waiting for the first reading" inside its limit after a start; the missing-reading age is counted when the page asks. - STYLE.md and DECISIONS/UX-08-short-notifications.md (UX-10 section). No change to safety behaviour, alarm levels, notification ids, triggers, cadence or the banner cascade. One row colour changes (meter at start), justified in DECISIONS. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
125b0702a2
commit
23a3a3f5b5
@@ -61,3 +61,18 @@ The allowlist is empty and its cap is 0 (43 → 0). Every WARNING and ERROR line
|
||||
10. **The panel's key match** no longer files `inverters.max_w` under the flat `max_w`.
|
||||
11. **The Supervisor question at start** is one INFO line with a real reason (a timeout's own text is empty, so the error type is named).
|
||||
12. **DOCS**: a glossary ("Words used on this page") explains control board, isolator and Developer Tools once. Card ids left the headings and sit on a *For installers* line under each. The links to the renamed headings were updated.
|
||||
|
||||
# UX-10: the last plain-language leftovers (after the 2d test)
|
||||
|
||||
**Unchanged:** every safety behaviour, every alarm's log level (WARNING and ERROR stay), every notification id, trigger and cadence, the banner cascade, and every row colour except the meter row right after a start (item 6).
|
||||
|
||||
1. **Why the 2d scan missed the clamp lines.** Part 3 reads a log call's own literal and counts `%s` as one word. The clamp lines are `"…software fault: %s …"`, and the text in `%s` was built elsewhere, by `loop_clamp_note()` and `ClampResult.describe()`. So the scan passed a line whose logged text had a semicolon, "BUG SIGNAL", "clamped" and "1 times". The same was true of every quoted reason. Part 6 closes the gap. It lists every dynamic part of every WARNING+ line as data (a number, a name, a path, a library's own error text) or as a built text, and a new part in neither list fails. Each built text is produced by the real code (the watchdogs, `decide()`, `loop_clamp_note()`, `MigrationReport.explain()`) or, for a family of builders, by every template of it (`PriceRead.no_data`, `Gate.block`). The text and the line as logged are then checked. A mutation shows the 2d clamp text is caught on both clamp lines.
|
||||
2. **A quoted reason gets the red-alarm shape**, 3 sentences of at most 30 words, and not the 25-word line limit. It is the evidence behind an alarm, and it keeps its code and its limits, which the owner asked to keep. The alarm shape is STYLE.md's existing rule for the texts behind a safety stop, so no new limit was made up. Rewritten: `OUTPUT_CLAMP` (both kinds), `METER_FROZEN`, `CIRCULATING_POWER`, `STALE_READING` (SAFETY-56's two explanations and "cannot tell which" kept, in order), the peak guard's reasons, the state-migration report, the price feed and price history reasons, and the maintenance and trading gate reasons. "Software fault" left the clamp reason, because the ERROR line around it already says it.
|
||||
3. **Codes are one token.** `PEAK GUARD`, `PEAK GUARD FLOOR-LIMITED` and `PEAK GUARD BLIND` read as capitals, so they are now `PEAK_GUARD`, `PEAK_GUARD_FLOOR_LIMITED` and `PEAK_GUARD_BLIND`, like `OUTPUT_CLAMP`. Nothing in admin/goodwe or in the scripts under `/home/homelab` greps them (checked). `/home/homelab/clampwatch.sh` greps `OUTPUT_CLAMP`, which stays.
|
||||
4. **Top table.** *Price history* writes "96 prices over 24 hours for 26 Sep", joined by commas. *Tariff* writes the spacing as "one every 15 minutes or every hour". "Not final yet" was dropped, because a plan is provisional exactly when it holds an estimated price (`n_carried` counts the provisional points), so the estimated count already says it.
|
||||
5. **Levels and noise.** The shadow line of every cycle is DEBUG, and "Shadow mode is on/off" is INFO: it follows a setting or a button, and the banner, hint and event are unchanged. aiohttp's access log is on only at log level debug. A settings warning is logged once per start (a filter on `goodwe.config`, WARNING only, so refusals are untouched), because the validator runs twice at start. When Home Assistant restarts, `hass.Outage` says so in one WARNING line for the REST API and the meter websocket together, puts the library's text on DEBUG, and says at INFO when both answer again. INFO lines lost "§8.3", ISO timestamps, "banked" and "keys ARE", and error texts lost "NOT_OBSERVED", "did NOT land" and "AND".
|
||||
6. **Display bugs.**
|
||||
- "Why: Other" during a latched per-inverter stop: `main.py` turns a safety winner into its claim's reason, and "sign disagreement" (and "unsplit", main.py's own refusal to split) had no entry in `WHY_WINNER`. The mapping is now `main.why_key()`, and part 7 finds every `Claim.set()` in the code and checks that every key it can produce has words.
|
||||
- Red "Meter: no reading for 0 seconds" after a restart: until the first reading arrives, `P1Ingest.stale` is true, and the age is the time since start. The row now reads amber "waiting for the first reading" while that age is inside the limit. **Colour change, justified:** red at 0 s contradicted the limit the same row prints, and once readings exist the row is red only past that limit. Amber, not green, because control waits for the reading. Past the limit it is red as before. `stale` itself, which gates control, is unchanged.
|
||||
- "A reading is missing for 0 seconds" stuck at 0: with the meter reading gone, the grid value stops changing, so the loop runs a cycle only every `cycle_floor_s`, and the line was computed once per cycle. The age is now counted when the page asks. The hold and its 15 s escalation are unchanged.
|
||||
7. **Witness** (admin/goodwe): the resolved push says "after no answers from … to …", as the resolved card does. The YAML with every title and message stripped is identical.
|
||||
|
||||
Reference in New Issue