diff --git a/README.md b/README.md index 037f702..c341fb3 100644 --- a/README.md +++ b/README.md @@ -50,6 +50,9 @@ https://gittea.kammenstraatha.duckdns.org/admin/goodwe-addon then install **GoodWe RS485 Controller**. +Then turn on **Watchdog** on the add-on's Info tab — see +[Before you start](goodwe_controller/DOCS.md#before-you-start). + ⚠️ **The repository must be PUBLIC for this to work.** Home Assistant clones it anonymously; against a private repo the store shows nothing and gives no useful error. If it must stay private, install locally instead: copy diff --git a/goodwe_controller/DOCS.md b/goodwe_controller/DOCS.md index 2f20647..87f0649 100644 --- a/goodwe_controller/DOCS.md +++ b/goodwe_controller/DOCS.md @@ -16,6 +16,11 @@ You need: - A T-CAN485 (ESP32) flashed with `firmware/goodwe-master.yaml` - A grid-power sensor already working in Home Assistant, updating every ~5–10 s +After installing, turn on **Watchdog** on the add-on's Info tab. A crashed +control loop stops the add-on at 0 W, and the Supervisor restarts it only when +Watchdog is on (it is off by default). See +`DECISIONS/SAFETY-61-control-task-death.md`. + ## The safety model, in short The inverter **holds its last command forever** — it has no meter-timeout. So: