EV-05 round 2: the peak cut waits 15 s while a battery can give
checks / unit (pull_request) Successful in 23m32s
infra-pin / fresh (pull_request) Successful in 1s

Owner 2026-11-18 (dev finding 1, brief v4 Expected 8): while a battery is
above its cut-out, the car's peak cut waits until the guard has wanted power
for 15 s in a row (CUT_WAIT_S), so a cloud edge the batteries catch does not
pause the car. It cuts at once with no battery able, or with 120 s or less of
the 15-minute period left (CUT_NEAR_END_S: waiting 15 s then costs at most
8/7 of the cut, taken off the car at once).

Tests: T21/T22 cut at 15 s and not sooner, the period lands under the aim;
T21b a house step and a cloud edge the batteries catch: no cut, no pause;
T24 (c) late in the period: the cut at once, under the aim; T12's cut row
with the batteries at their cut-out. The harness's battery level model was
1000x too fast (round 1); fixed. The 10-hour day: 0 cut pauses in both
priorities.

Co-Authored-By: Claude <noreply@anthropic.com>
This commit is contained in:
ems-agent
2026-11-18 10:13:02 +01:00
co-authored by Claude
parent 8ba3e1c337
commit 17a7b299d2
6 changed files with 152 additions and 39 deletions
@@ -25,6 +25,17 @@ inputs (`car_sun_inputs`) and runs the writer in the same background task.
(`wanted_w > 0`), and by `min(excess, wanted)`. Batteries that only stop
charging in a cloud's first seconds are not "asked", so a cloud does not cut
the car. A partial cut caps the car for the rest of that 15-minute period.
- **The cut waits 15 s while a battery can still give** (owner 2026-11-18,
round 2): `ctl_car.CUT_WAIT_S`, counted from the first cycle in a row in
which the guard wants power. A battery "can give" when it is above its own
cut-out level, not refusing to give and not under a safety stop
(`_car_batt_able`). It cuts at once with nothing able, or with 120 s or less
of the period left (`CUT_NEAR_END_S`): waiting 15 s with R s left raises what
must come off afterwards by R / (R - 15), at most 8/7 at 120 s, and the cut
then takes it off the car at once. test_ev05.py T21 (a step beyond the
batteries, cut at 15 s) and T24 (c) (a late step, cut at once) show the period
landing under the aim; the 10-hour day of test_ev05_long.py has no cut
pause at the shipped `slew_w` 0.
- **The 4.0 to 4.14 kW band on 3 phases.** 3 phases need 4.14 kW at 6 A, the
switch back to 1 phase is under 4.0 kW. Inside that band the car holds 6 A on
3 phases with no pause count (the hysteresis the design chose). Under 4.0 kW