UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only refusal, the add-on now serves the setup wizard in setup-only mode instead of exiting 78. It builds no controller, MQTT client or meter task, its HomeAssistant is read-only (every service call refuses before sending), Controller refuses a read-only HomeAssistant, and /action answers 409. Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md. Wizard fixes from the UX-13 P4 test: - F1: /config/validate converts what it can, so a conversion error blocks its own step and the live checks still run; save 422 carries steps. - F2: saves send the model the page opened (base); only keys this page changed are written onto the blob stored now. - A meter entity missing from Home Assistant is red on the last step. - Step 1 says the reading went down after a skip that followed a fall. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -3233,19 +3233,35 @@ the last step.
|
||||
sign for you; with a net or import/export meter it tells you what to change.
|
||||
- **The last step** runs the add-on's own start checks and reads Home
|
||||
Assistant: the meter reading, that each power request entity exists, the
|
||||
battery levels, and whether prices are known. A missing power request entity
|
||||
is red, so it cannot be saved.
|
||||
battery levels, and whether prices are known. A missing power request or
|
||||
meter entity is red, so it cannot be saved.
|
||||
- **Save and restart** saves, then restarts the add-on. Every inverter is set
|
||||
to 0 W while it restarts, and with "Start in shadow mode" on (the default) it
|
||||
stays at 0 W until you turn shadow mode off under Settings.
|
||||
|
||||
Setup opens by itself on a new install's first start, until Setup finishes or
|
||||
control is started, and whenever the stored settings name no inverter to
|
||||
control. A site that already ran before is never sent there. The add-on does
|
||||
not start with no power request entity at all, so on a brand-new install fill
|
||||
in "Inverter setpoint entity" on the Configuration tab first.
|
||||
control. A site that already ran before is never sent there.
|
||||
|
||||
*For installers: card UX-13, and `DECISIONS/UX-13-setup-wizard.md`.*
|
||||
A new install names no inverter yet, so the add-on starts **in setup**: it
|
||||
serves the page and sends nothing to any inverter. Home says "Setup: the
|
||||
add-on controls nothing until setup is done", and there is no Start button. The
|
||||
installer's steps:
|
||||
|
||||
1. Install the add-on, turn on **Watchdog** on its Info tab, and start it.
|
||||
Leave the Configuration tab as it is.
|
||||
2. Open the add-on's page. Setup opens by itself.
|
||||
3. Go through the six steps and press **Save and restart**. With "Start in
|
||||
shadow mode" on, every inverter stays at 0 W after the restart.
|
||||
4. On Home, check the meter direction and what the add-on would do. Turn
|
||||
shadow mode off under Settings when it looks right.
|
||||
|
||||
Any other problem in the stored settings still stops the add-on (exit code 78),
|
||||
and the log names each one. Fix those on the Configuration tab.
|
||||
|
||||
*For installers: cards UX-13 and UX-15, `DECISIONS/UX-13-setup-wizard.md` and
|
||||
`DECISIONS/UX-15-setup-only-mode.md`. In setup the `status` JSON has
|
||||
`setup_only: true`, and no MQTT entity is published.*
|
||||
|
||||
## Status page
|
||||
|
||||
@@ -3260,6 +3276,10 @@ inverter stays at 0 W. If the banner is red and says a safety stop stays on,
|
||||
one of the red rows below is a stop that will still be there when shadow mode
|
||||
ends. That row says how to clear it.
|
||||
|
||||
In **setup** (a new install that names no inverter yet) the banner says the
|
||||
add-on controls nothing until setup is done, and the one row says to finish
|
||||
Setup. See *Setup, for a new install*.
|
||||
|
||||
| Row starts with | What it tells you |
|
||||
|---|---|
|
||||
| Control | When control last ran. Red when it has stopped running: the control board then sets the inverter to 0 W. |
|
||||
|
||||