UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1

A new install names no inverter. When that is the startup gate's only
refusal, the add-on now serves the setup wizard in setup-only mode instead
of exiting 78. It builds no controller, MQTT client or meter task, its
HomeAssistant is read-only (every service call refuses before sending),
Controller refuses a read-only HomeAssistant, and /action answers 409.
Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md.

Wizard fixes from the UX-13 P4 test:
- F1: /config/validate converts what it can, so a conversion error blocks
  its own step and the live checks still run; save 422 carries steps.
- F2: saves send the model the page opened (base); only keys this page
  changed are written onto the blob stored now.
- A meter entity missing from Home Assistant is red on the last step.
- Step 1 says the reading went down after a skip that followed a fall.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-09-28 08:48:21 +02:00
co-authored by Claude Opus 5.5
parent 4de96752ff
commit 159d7461d8
20 changed files with 1075 additions and 71 deletions
@@ -148,6 +148,11 @@ exits 78 and the panel goes with it. Recovery is the Configuration tab. That is
the reason it stays, and the reason the panel refuses to write a blob the
validator rejected: this surface must never be the thing that removes itself.
*Amended by [[UX-15-setup-only-mode]] (2026-09-28):* one refused configuration
keeps the panel: options that name no inverter at all and have no other
refusal, which is what a new install ships. The add-on then serves the page in
setup-only mode and commands nothing. Every other refusal still exits 78.
**The panel shows fewer refusals than the startup gate can, never more.** Two
of `validate.py`'s rules compare a configured ceiling against the setpoint
device's *own* reported range, which is only knowable by asking Home Assistant.
@@ -25,8 +25,9 @@ The page opens `#setup` only when it is opened with no route, and only when
- **`no_power_request`**: the stored options name no inverter to control.
- **`first_start`**: this boot found no `/data/state.json` (`Store.fresh`), the
Store has no `setup_done` and no `auto` key, and control is not started.
`auto` is the key Start/Stop writes. The startup gate exits 78 before the
controller writes the Store, so a new install's first good boot is fresh.
`auto` is the key Start/Stop writes. Neither the startup gate's exit 78 nor
setup-only mode (UX-15) writes the Store, so a new install's first good boot
is fresh.
"Never started" alone is not enough: both TEST-23 add-ons have `auto_start`
off and no `auto` key, and one has run in shadow for weeks (review of PR #146,
@@ -37,14 +38,12 @@ started or stopped it, is never sent. Without a Store the answer is no. The wiza
`setup_done` (an ISO time) to the Store. A save from the Installer view does
not.
**Not decided here, for the owner:** the add-on exits 78 before it serves the
page when the stored options name no power request entity, which is what a
brand-new install ships (config.yaml's `setpoint_entity: ""`). So on a truly
new install the installer fills in "Inverter setpoint entity" on the
Configuration tab first, and the wizard opens on the next page visit.
Serving a setup-only page from a refused configuration would change the CFG-01
startup gate and UX-02 §4 ("the panel is not available when it is most
needed"), so it is left as an open question.
**Decided since, in [[UX-15-setup-only-mode]] (owner, 2026-09-28):** a
brand-new install ships `setpoint_entity: ""`, and it no longer exits 78. When
naming no inverter is the gate's only refusal, the add-on serves the page in
setup-only mode, which commands nothing, and the wizard opens with
`no_power_request`. Setup-only mode writes no Store file, so the first-run
rule above still holds for an install set up on the Configuration tab.
## 3. The kettle test and the sign checks
@@ -96,6 +95,7 @@ fingerprint was not handed out by this process, it falls back to `changed`.
it), step blocking, the first-run rule on new and TEST-23 sites, the live
checks, the save through the P2 path, the stale fix, and the words.
- tools/ux13_wizard_blobs.py produces every blob the wizard can save from a new
install and three TEST-23 sites (88 accepted by the shipped validator). At P4
install and three TEST-23 sites (88 accepted by the shipped validator).
UX-15 added the shipped defaults as a start (setup-only mode). At P4
all 88 were accepted by Supervisor 2026.08.0's `AppOptions`, offline, 78
keys each.
@@ -0,0 +1,110 @@
# UX-15 — setup-only mode: a new install serves the wizard
**Status: DECIDED 2026-09-28 (owner decision; UX-15 dev).** Card
6aba0053d27a32cb3f210dcc. Changes the CFG-01 startup gate and closes the open
question in [[UX-13-setup-wizard]] §2. Amends [[UX-02-two-config-surfaces]] §4.
## 1. The rule
`config.yaml` ships `setpoint_entity: ""`, so a new install's options are
refused by rule 1 of `validate_startup_config()`: no inverter to control.
Until now that was exit 78 before any page was served, and the installer had
to fill in the entity on the Configuration tab before the wizard could open.
The add-on now starts in **setup-only mode** when, and only when
(`setuponly.applies()`):
- the options name no inverter at all: no flat `setpoint_entity` and no
`inverters` entry, and
- rule 1's refusal (`no_power_request_problem()`) is the gate's **only**
refusal.
In setup-only mode it serves the page, says it is in setup (banner, `/status`
`setup_only: true`, a WARNING log line) and opens the wizard when the page is
opened with no route (`setup_needed` is `no_power_request`). After the
wizard's save and restart the normal gate applies to the saved options.
## 2. What still exits 78, and why
Everything else the gate refuses, including:
- a complete configuration that is refused, e.g. `maintenance_charge_w` above
`max_w`;
- no power request entity **and** any other refusal;
- an `inverters` list whose entry has a blank power request entity.
These are configurations somebody edited. The Configuration tab stored them,
the log's refusal banner names each problem, and the tab is where they are
fixed (UX-02 §4). Serving the wizard there would put a six-step setup in
front of someone who needs to change one field. A narrow rule also keeps the
setup-only decision to one comparison against one known sentence, so a new
validator rule cannot widen it by accident: any other refusal fails the
equality and exits 78.
The cost: an installer who first sets, say, a DSMR meter with no entities on
the Configuration tab and leaves the power request entity empty gets exit 78,
not the wizard. The log then names both fields.
## 3. Why it cannot command
Setup-only mode builds nothing that commands. `amain()` branches to
`setuponly.serve()` before the MQTT broker, the controller, the meter task and
the tariff task are built, and it returns from there when the Supervisor
stops it. What serves the page is `SetupOnly`, which holds no inverter.
Three checks make it structural rather than a convention:
1. **The HomeAssistant is read-only** (`HomeAssistant(read_only=True)`).
`call()` refuses before it sends anything, and every service call goes
through it: `number.set_value` (`set_number()`), notifications, all of
them. The flag is fixed at construction, and there is no setter.
2. **`SetupOnly` refuses a HomeAssistant that can write, and `Controller`
refuses one that cannot.** So neither can be built on the wrong one.
3. **`/action` answers 409** in setup-only mode, before
`handle_action()`. Start, Stop and the battery cycle do nothing.
No MQTT client is created, so nothing is published. The page's other routes
already read only, or write the add-on's own options (UX-02 §6).
Setup-only mode writes no Store file. The wizard's save writes `setup_done`,
as in any mode. So a new install that is set up on the Configuration tab
instead still has a fresh Store on its first normal boot, and the first-run
rule (UX-13 §2) sends it to the wizard as before.
## 4. How it is held
- `test_setup_only.py` part 1: when it applies, including the three exit-78
cases above. Part 2: the read-only write path refuses with nothing sent,
and the two constructors refuse. Part 3 boots the real `main()` on the
shipped defaults against a fake Supervisor and Home Assistant over HTTP and
logs every request: the page is served, `/status` says setup-only, Start
and the cycle get 409, and there are 0 service calls and no MQTT request,
also with `auto_start` on and a Store that says control was started. The
wizard's save is then booted: it passes the normal gate, does not open the
wizard again, and every write is 0 W (shadow). Part 4: the refused
configurations exit 78 and serve nothing.
- Mutations, each red: `applies()` always false or always true, the
read-only refusal removed, the Controller's check removed, `amain()` giving
setup-only mode a writable HomeAssistant, `/action`'s 409 removed, and the
`return` after `serve()` removed.
- TEST-23: a real container on the shipped defaults, with the Supervisor
stand-in logging every service call (the PR has the evidence).
## 5. The wizard fixes in the same card
- **F1.** `/config/validate` converts what it can of a page model
(`uimodel.ui_to_options_partial()`), so a conversion error blocks its own
step beside its field and the live checks still run on the rest. A refusal
about a key the failed conversion writes is left out, because it would
judge the stored value. The save still refuses such a model (422, with
`steps`).
- **F2.** A save from the page model sends `base`, the model it opened. The
add-on writes only the keys whose value differs from `base`, onto the blob
stored now (`uipage.only_edits()`). So "save again to keep yours" after a
409 keeps the other surface's changes. A key both surfaces changed takes
this page's value, which is what the second press after the banner means.
- **Meter entity.** On the last step a meter entity Home Assistant does not
have is red, like a missing power request entity, so a skipped kettle test
cannot let it through. In the Installer view it stays a warning.
- **Step 1 after a skip.** When the kettle test saw the reading fall and was
then skipped, step 1 says the reading went down. The skip stays (UX-13 §3).