UX-15: setup-only mode, and the wizard fixes F1, F2, meter, step 1
A new install names no inverter. When that is the startup gate's only refusal, the add-on now serves the setup wizard in setup-only mode instead of exiting 78. It builds no controller, MQTT client or meter task, its HomeAssistant is read-only (every service call refuses before sending), Controller refuses a read-only HomeAssistant, and /action answers 409. Any other refusal still exits 78. DECISIONS/UX-15-setup-only-mode.md. Wizard fixes from the UX-13 P4 test: - F1: /config/validate converts what it can, so a conversion error blocks its own step and the live checks still run; save 422 carries steps. - F2: saves send the model the page opened (base); only keys this page changed are written onto the blob stored now. - A meter entity missing from Home Assistant is red on the last step. - Step 1 says the reading went down after a skip that followed a fall. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
@@ -148,6 +148,11 @@ exits 78 and the panel goes with it. Recovery is the Configuration tab. That is
|
||||
the reason it stays, and the reason the panel refuses to write a blob the
|
||||
validator rejected: this surface must never be the thing that removes itself.
|
||||
|
||||
*Amended by [[UX-15-setup-only-mode]] (2026-09-28):* one refused configuration
|
||||
keeps the panel: options that name no inverter at all and have no other
|
||||
refusal, which is what a new install ships. The add-on then serves the page in
|
||||
setup-only mode and commands nothing. Every other refusal still exits 78.
|
||||
|
||||
**The panel shows fewer refusals than the startup gate can, never more.** Two
|
||||
of `validate.py`'s rules compare a configured ceiling against the setpoint
|
||||
device's *own* reported range, which is only knowable by asking Home Assistant.
|
||||
|
||||
@@ -25,8 +25,9 @@ The page opens `#setup` only when it is opened with no route, and only when
|
||||
- **`no_power_request`**: the stored options name no inverter to control.
|
||||
- **`first_start`**: this boot found no `/data/state.json` (`Store.fresh`), the
|
||||
Store has no `setup_done` and no `auto` key, and control is not started.
|
||||
`auto` is the key Start/Stop writes. The startup gate exits 78 before the
|
||||
controller writes the Store, so a new install's first good boot is fresh.
|
||||
`auto` is the key Start/Stop writes. Neither the startup gate's exit 78 nor
|
||||
setup-only mode (UX-15) writes the Store, so a new install's first good boot
|
||||
is fresh.
|
||||
|
||||
"Never started" alone is not enough: both TEST-23 add-ons have `auto_start`
|
||||
off and no `auto` key, and one has run in shadow for weeks (review of PR #146,
|
||||
@@ -37,14 +38,12 @@ started or stopped it, is never sent. Without a Store the answer is no. The wiza
|
||||
`setup_done` (an ISO time) to the Store. A save from the Installer view does
|
||||
not.
|
||||
|
||||
**Not decided here, for the owner:** the add-on exits 78 before it serves the
|
||||
page when the stored options name no power request entity, which is what a
|
||||
brand-new install ships (config.yaml's `setpoint_entity: ""`). So on a truly
|
||||
new install the installer fills in "Inverter setpoint entity" on the
|
||||
Configuration tab first, and the wizard opens on the next page visit.
|
||||
Serving a setup-only page from a refused configuration would change the CFG-01
|
||||
startup gate and UX-02 §4 ("the panel is not available when it is most
|
||||
needed"), so it is left as an open question.
|
||||
**Decided since, in [[UX-15-setup-only-mode]] (owner, 2026-09-28):** a
|
||||
brand-new install ships `setpoint_entity: ""`, and it no longer exits 78. When
|
||||
naming no inverter is the gate's only refusal, the add-on serves the page in
|
||||
setup-only mode, which commands nothing, and the wizard opens with
|
||||
`no_power_request`. Setup-only mode writes no Store file, so the first-run
|
||||
rule above still holds for an install set up on the Configuration tab.
|
||||
|
||||
## 3. The kettle test and the sign checks
|
||||
|
||||
@@ -96,6 +95,7 @@ fingerprint was not handed out by this process, it falls back to `changed`.
|
||||
it), step blocking, the first-run rule on new and TEST-23 sites, the live
|
||||
checks, the save through the P2 path, the stale fix, and the words.
|
||||
- tools/ux13_wizard_blobs.py produces every blob the wizard can save from a new
|
||||
install and three TEST-23 sites (88 accepted by the shipped validator). At P4
|
||||
install and three TEST-23 sites (88 accepted by the shipped validator).
|
||||
UX-15 added the shipped defaults as a start (setup-only mode). At P4
|
||||
all 88 were accepted by Supervisor 2026.08.0's `AppOptions`, offline, 78
|
||||
keys each.
|
||||
|
||||
@@ -0,0 +1,110 @@
|
||||
# UX-15 — setup-only mode: a new install serves the wizard
|
||||
|
||||
**Status: DECIDED 2026-09-28 (owner decision; UX-15 dev).** Card
|
||||
6aba0053d27a32cb3f210dcc. Changes the CFG-01 startup gate and closes the open
|
||||
question in [[UX-13-setup-wizard]] §2. Amends [[UX-02-two-config-surfaces]] §4.
|
||||
|
||||
## 1. The rule
|
||||
|
||||
`config.yaml` ships `setpoint_entity: ""`, so a new install's options are
|
||||
refused by rule 1 of `validate_startup_config()`: no inverter to control.
|
||||
Until now that was exit 78 before any page was served, and the installer had
|
||||
to fill in the entity on the Configuration tab before the wizard could open.
|
||||
|
||||
The add-on now starts in **setup-only mode** when, and only when
|
||||
(`setuponly.applies()`):
|
||||
|
||||
- the options name no inverter at all: no flat `setpoint_entity` and no
|
||||
`inverters` entry, and
|
||||
- rule 1's refusal (`no_power_request_problem()`) is the gate's **only**
|
||||
refusal.
|
||||
|
||||
In setup-only mode it serves the page, says it is in setup (banner, `/status`
|
||||
`setup_only: true`, a WARNING log line) and opens the wizard when the page is
|
||||
opened with no route (`setup_needed` is `no_power_request`). After the
|
||||
wizard's save and restart the normal gate applies to the saved options.
|
||||
|
||||
## 2. What still exits 78, and why
|
||||
|
||||
Everything else the gate refuses, including:
|
||||
|
||||
- a complete configuration that is refused, e.g. `maintenance_charge_w` above
|
||||
`max_w`;
|
||||
- no power request entity **and** any other refusal;
|
||||
- an `inverters` list whose entry has a blank power request entity.
|
||||
|
||||
These are configurations somebody edited. The Configuration tab stored them,
|
||||
the log's refusal banner names each problem, and the tab is where they are
|
||||
fixed (UX-02 §4). Serving the wizard there would put a six-step setup in
|
||||
front of someone who needs to change one field. A narrow rule also keeps the
|
||||
setup-only decision to one comparison against one known sentence, so a new
|
||||
validator rule cannot widen it by accident: any other refusal fails the
|
||||
equality and exits 78.
|
||||
|
||||
The cost: an installer who first sets, say, a DSMR meter with no entities on
|
||||
the Configuration tab and leaves the power request entity empty gets exit 78,
|
||||
not the wizard. The log then names both fields.
|
||||
|
||||
## 3. Why it cannot command
|
||||
|
||||
Setup-only mode builds nothing that commands. `amain()` branches to
|
||||
`setuponly.serve()` before the MQTT broker, the controller, the meter task and
|
||||
the tariff task are built, and it returns from there when the Supervisor
|
||||
stops it. What serves the page is `SetupOnly`, which holds no inverter.
|
||||
|
||||
Three checks make it structural rather than a convention:
|
||||
|
||||
1. **The HomeAssistant is read-only** (`HomeAssistant(read_only=True)`).
|
||||
`call()` refuses before it sends anything, and every service call goes
|
||||
through it: `number.set_value` (`set_number()`), notifications, all of
|
||||
them. The flag is fixed at construction, and there is no setter.
|
||||
2. **`SetupOnly` refuses a HomeAssistant that can write, and `Controller`
|
||||
refuses one that cannot.** So neither can be built on the wrong one.
|
||||
3. **`/action` answers 409** in setup-only mode, before
|
||||
`handle_action()`. Start, Stop and the battery cycle do nothing.
|
||||
|
||||
No MQTT client is created, so nothing is published. The page's other routes
|
||||
already read only, or write the add-on's own options (UX-02 §6).
|
||||
|
||||
Setup-only mode writes no Store file. The wizard's save writes `setup_done`,
|
||||
as in any mode. So a new install that is set up on the Configuration tab
|
||||
instead still has a fresh Store on its first normal boot, and the first-run
|
||||
rule (UX-13 §2) sends it to the wizard as before.
|
||||
|
||||
## 4. How it is held
|
||||
|
||||
- `test_setup_only.py` part 1: when it applies, including the three exit-78
|
||||
cases above. Part 2: the read-only write path refuses with nothing sent,
|
||||
and the two constructors refuse. Part 3 boots the real `main()` on the
|
||||
shipped defaults against a fake Supervisor and Home Assistant over HTTP and
|
||||
logs every request: the page is served, `/status` says setup-only, Start
|
||||
and the cycle get 409, and there are 0 service calls and no MQTT request,
|
||||
also with `auto_start` on and a Store that says control was started. The
|
||||
wizard's save is then booted: it passes the normal gate, does not open the
|
||||
wizard again, and every write is 0 W (shadow). Part 4: the refused
|
||||
configurations exit 78 and serve nothing.
|
||||
- Mutations, each red: `applies()` always false or always true, the
|
||||
read-only refusal removed, the Controller's check removed, `amain()` giving
|
||||
setup-only mode a writable HomeAssistant, `/action`'s 409 removed, and the
|
||||
`return` after `serve()` removed.
|
||||
- TEST-23: a real container on the shipped defaults, with the Supervisor
|
||||
stand-in logging every service call (the PR has the evidence).
|
||||
|
||||
## 5. The wizard fixes in the same card
|
||||
|
||||
- **F1.** `/config/validate` converts what it can of a page model
|
||||
(`uimodel.ui_to_options_partial()`), so a conversion error blocks its own
|
||||
step beside its field and the live checks still run on the rest. A refusal
|
||||
about a key the failed conversion writes is left out, because it would
|
||||
judge the stored value. The save still refuses such a model (422, with
|
||||
`steps`).
|
||||
- **F2.** A save from the page model sends `base`, the model it opened. The
|
||||
add-on writes only the keys whose value differs from `base`, onto the blob
|
||||
stored now (`uipage.only_edits()`). So "save again to keep yours" after a
|
||||
409 keeps the other surface's changes. A key both surfaces changed takes
|
||||
this page's value, which is what the second press after the banner means.
|
||||
- **Meter entity.** On the last step a meter entity Home Assistant does not
|
||||
have is red, like a missing power request entity, so a skipped kettle test
|
||||
cannot let it through. In the Installer view it stays a warning.
|
||||
- **Step 1 after a skip.** When the kettle test saw the reading fall and was
|
||||
then skipped, step 1 says the reading went down. The skip stays (UX-13 §3).
|
||||