EV-20 review r3: a held read moves no plan count; only the meter-age pause may fire
On a held charger read no writer steps and the Solar plan does nothing: no phase change or switching start begins, no _set or end_switch, ok_since, up_since, down_since, low_since and set_at stay, and the hold pause does not fire; a decision due then runs on the next real reading. The one exception is the pause by the meter's age (C18, SolarWriter.held_pause). Rows: the reviewer's three shapes with 1- and 2-read gaps on and before the decision cycle, and the hold pause on a held cycle. DECISIONS wording fixed. Co-Authored-By: Claude <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01VSY9UpTaUYnjJF5oVtbM1w
This commit is contained in:
@@ -152,8 +152,11 @@ one small set of facts and derives every path from them:
|
||||
that got no answer, or every required entity unavailable; one entity
|
||||
missing, a wrong power unit or the login off stay readings of their own
|
||||
(EV-03 round 4, unchanged); nothing is decided
|
||||
or written in that cycle (`ctl_car.car_step` returns), and it neither arms
|
||||
nor clears the stuck check. At `stale_input_s` the missing reading is taken
|
||||
or written in that cycle: no writer steps (`ctl_car.car_step` returns), no
|
||||
plan count moves (start, phase change, hold, `set_at`) and a decision due
|
||||
then runs on the next real reading (review r3, PM design). The one
|
||||
exception is Solar's pause by the meter's age (C18, `held_pause`). It
|
||||
neither arms nor clears the stuck check. At `stale_input_s` the missing reading is taken
|
||||
as before (the safe path: the charger is gone, 0 A first on its return).
|
||||
This also ends the false PEAK_GUARD_FLOOR_LIMITED after one gap (EV-18
|
||||
T10(b) changed accordingly).
|
||||
@@ -166,9 +169,11 @@ one small set of facts and derives every path from them:
|
||||
current: no retry, no raise, no phase change begun, and a phase change
|
||||
under way ends at its 0 A (no select after that, no closing current); the
|
||||
plan pauses. 0 A is always allowed. Also on a held read (`nz_block`).
|
||||
- **The age pause on a held read (C18):** on a held cycle Solar still steps
|
||||
(Manual does not), so a pause due on that cycle is not slipped; it can only
|
||||
write a NEW 0 A there (no retry to a charger that is not answering).
|
||||
- **The age pause on a held read (C18):** on a held cycle Solar does not step
|
||||
(review r3, PM design); only `held_pause` runs: while the meter is silent
|
||||
and its age has reached `meter_max_age_s` + `ev_pause_min`, the plan pauses
|
||||
and a NEW 0 A goes out (no retry to a charger that is not answering). No
|
||||
phase change, start, hold pause or other count moves on a held cycle.
|
||||
- **Accepted (PM, P9g):** a frozen charger that also stops answering is
|
||||
flagged only once it answers again; the 15 s safe path covers the gap.
|
||||
- **A held read during a phase change (SPIKE-06 C19):** a phase change under
|
||||
|
||||