MAINT-10: every pack at N=2, the next DST days, plainer upgrade note
test_maint10.py part 10: at two inverters both packs get the site zone, the real Controller is identical for 11 UTC and 13 Brussels, and two due packs across 24/25 Oct 2026 and 27/28 Mar 2027 start at the local hour on successive days; a pack freed in the repeated hour does not start there. Part 3 adds 28 Mar 2027. DOCS: an existing install keeps its saved hour, now read as local time; an hour set to make up for UTC goes back to 19. DECISIONS: the SAFETY-83 gate is met; section on two inverters. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
08fb1235fc
commit
0b6b34f563
@@ -1655,14 +1655,16 @@ help - see "Why the tuning is what it is".
|
||||
it uses the add-on's own time zone, and failing that UTC. The log says which
|
||||
one it used. On the day the clocks go forward, a start hour that does not exist
|
||||
starts at the first hour after the jump. On the day they go back, a repeated
|
||||
hour starts only once, in its first pass.
|
||||
hour starts only once, in its first pass. With two inverters both batteries use
|
||||
the same local hour; one cycles at a time, and the other starts at that hour on
|
||||
a later day.
|
||||
|
||||
**Upgrading.** The hour used to be read as UTC, so the old default of 10
|
||||
started at 12:00 in a Belgian summer. The default is now 19 (19:00 local), but
|
||||
it only reaches installs whose saved settings lack the hour. Saving the
|
||||
settings stores every value, so most existing installs have 10 saved. They keep
|
||||
10, and it now means 10:00 local. The add-on never changes a saved value: set
|
||||
19 yourself for the evening start. *For installers:* DECISIONS/MAINT-10-local-start-hour.md.
|
||||
**Upgrading.** The hour used to be read as UTC. An existing install keeps its
|
||||
saved hour, and that hour now means local time: a saved 10 now starts at 10:00,
|
||||
not 12:00 in summer. The new default, 19, only reaches installs that have no
|
||||
hour saved. If you set an earlier hour to get an evening start in UTC (for
|
||||
example 17 for 19:00 in summer), set it to 19. The add-on never changes a saved
|
||||
value. *For installers:* DECISIONS/MAINT-10-local-start-hour.md.
|
||||
|
||||